Manuale d’uso / di manutenzione del prodotto LW1200ER del fabbricante LG Electronics
Vai alla pagina of 28
LG Window-Type Air Conditioner OWNER'S MANUAL LG website http://www.lgservice.com MODELS, MODELOS: WK Series: LW7000ER LW8000ER WL Series: L1004R LW1000ER L1204R LW1200ER L1404R LB1000ER LB1200ER WP Series: LW1400ER L1504R LW1500ER L1804R LW1800ER ESPAÑOL ENGLISH IMPORTANT Please read through this manual.
2 Window-T ype Air Conditioner Owner’ s Manual T ABLE OF CONTENTS FOR Y OUR RECORDS Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealer's Name Date Purchased ■ Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
3 ENGLISH Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
4 ■ Operation Plug in the power plug properly. • Otherwise, it will cause electric shock or fire due to heat generation or electric shock. Do not operate or stop the unit by inserting or pulling out the power plug. • It will cause electric shock or fire due to heat generation.
5 ENGLISH Do not allow water to run into electric parts. • It will cause failure of machine or electric shock. Leave the door closed while the air conditioner is running. • It is not designed to cool the entire house. Ventilate before operating air conditioner when gas goes out.
6 Do not place heavy object on the power cord and take care so that the cord should not be pressed. • There is danger of fire or electric shock. If water enters the product, turn off the the power switch of the main body of appliance. Contact service center after taking the power-plug out from the socket.
Prior to Operation Safety Precautions 7 ENGLISH Preparing for operation Contact an installation specialist for installation. Plug in the power plug properly. Do not share the same outlet with other appliances Do not use an extension cord. Do not start/stop operation by plugging/unplugging the power cord.
TIMER MODE AIR PURIFIER TEMP PO WER FA N SPEED COOL INDOOR DESIRED ENERGY SA VER AIR PURIFIER CLEAN FIL TER FA N FA N DRY 1 2 7 3 4 5 6 Air Purifier Pow er Te mp Sleep Mode Timer Auto Swing Fan Speed .
ENGLISH 9 Push out the cover on the back of the remote control with your thumb Pay attention to polarity and insert two new AAA 1.5V batteries. Reattach the cover.
10 VENT CLOSE OPEN Part A Adjusting the Air Flow Direction Operating Instructions V ent Control For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation.
Drain pipe Drain cap Care and Maintenance Care and Maintenance 11 ENGLISH Turn the power off and unplug the power plug before cleaning the air conditioner. Air Filter The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner.
CABINET DRAIN PAN DRAIN HOSE SCREW 12 After removing the Air Purifying Filter, pull slightly forward to remove the Air Purifying filter. Soak the Air Purifying Filter in water mixed with a mild detergent for 20~30 minutes. Dry the Air Purifying Filter in the shade for a day.
ENGLISH 4 6 5 8 1 2 3 13 11 14 12 10 7 17 16 B A Power cord Power cord 9 15 13 Har dware Installation Hard ware Installation Product Features 1. CABINET 2. FRONT GRILLE 3. AIR FILTER 4. AIR INTAKE (INLET GRILLE) 5. AIR DISCHARGE 6. VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER) 7.
14 About 1 / 2 " 30"~60" Awning Cooled air Fence Over 20" Heat radiation 25" to 36" Offset 1 / 2 " to 1 1 / 4 " Sill Exterior Interior wall 20 1 / 12 " min.
15 ENGLISH About 1 / 2 " 30"~60" Awning Cooled air Fence Over 20" Heat radiation 27" to 39" Offset 1 / 2 " to 1 1 / 4 " Sill Exterior Interior wall 23 5 / 8 " min.
16 About 1 / 2 " 30"~60" Awning Cooled air Fence Over 20" Heat radiation 29" to 41" 18" min. Inner sill Offset Window Sash Sill Exterior Interior wall 29" min. (Without frame cur tain) How to Install the Unit To prevent vibration and noise, make sure the unit is installed securely and firmly.
ENGLISH 1 2 3 4 8 13 10 7 6 5 9 12 11 10 13 Shipping Screws (Type A) Upper guide Upper guide (Type A) 5 11 11 5 5 Upper guide 17 Installation Kits Contents Suggested T ool Requirements NO.
18 INDOOR OUTDOOR Sill Support 2 Nut 4 Bolt 3 INDOOR OUTDOOR Cabinet About 1 / 2 " Frame Guide 11 Screw(Type A) 5 Upper Guide Window stool Front Angle Window Sash Upper guide Frame Curtain 1 Foam-pe 10 Foam-pe 13 Cabinet Fig. 1 Fig. 2 Fig. 3 Fig.
19 ENGLISH Sash track Front Angle About 1 / 2 " Screw(Type B) 6 Screw(Type B) 6 Sill Support 2 Sill Support 2 Foam-Strip 8 Fig. 5 Type C 7 Fig. 6 Screw(Type A) Screw (Type A) Power cord Fig. 7 Fig. 8 The cabinet should be installed with a very slight tilt (about 1/2") downward toward the outside (See Fig.
20 Window locking bracket 12 Fig. 9 Fig. 10 Fig. 11 Attach the Window Locking Bracket w i t haT y p e C screw .( S e eF i g .9 ) Attach the front grille to the cabinet by inserting the t a b so nt h eg r i l l ei n t ot h et a b so nt h ef r o n to ft h e cabinet.
21 ENGLISH 11 14 Shipping Screws D E F R O S T H E A T C O O L I N D O O R D E S I R E D E N E R G Y S A V E R A I R P U R Y F I E R A U T O R E S T A R T F A N F A N D R Y D E F R O S T H E A T C O O.
22 3 9 2 6 3 14 11 2 4 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Support Bracket Lock nut Sill Bracket Carriage Bolt Front angle W indow stool Window sash Upper Guide Cabinet Foam -Seal Frame curtain Foam-PE (T.
23 ENGLISH (Type C) 6 7 Fig. 16 Fig. 17 Fig. 18 Fig. 19 Fig. 20 Screw Screw D E F R O S T H E A T C O O L I N D O O R D E S I R E D E N E R G Y S A V E R A I R P U R Y F I E R A U T O R E S T A R T F .
24 Fig. 21 T I M E M O D E T E M P P O W E R F A N S P E E D Do not under any circumstances cut or remove the grounding prong from the plug. Line Cord Plug Use Wall Receptacle Power Supply Power supply cord with 3-prong grounding plug Standard 125V, 3-wire grounding receptacle rated 15A, 125V AC Use 15 AMP, time delay fuse or circuit breaker.
25 ENGLISH PREFERRED METHOD Ensure proper ground exists before use TEMPORARY METHOD Adapter plug Receptacle cover Metal screw Fig. 22 Fig. 23 25 Electrical Safety IMPORTANT (PLEASE READ CAREFULLY) FOR.
26 PREFERRED METHOD Ensure proper ground exists before use Fig. 24 3-prong grounding plug Ground prong Power supply cord 3-prong grounding type wall receptacle Electrical Sa f ety ( L1804R, L W1800ER .
27 ENGLISH 27 Common Pr oblems and Solutions Common Issues Before calling for service, please review the following list of common problems and solutions. The air conditioner is operating normally when: • You hear a pinging noise. This is caused by water being picked up by the condenser on rainy days or in highly humid conditions.
WARRANTY PERIOD: HOW SERVICE IS HANDLED: The warranted labor covers the cost of In-Home Service on all parts including the compressor. THIS LIMITED WARRANTY DOES NOT APPLY TO: CUSTOMER INTER-ACTIVE CE.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il LG Electronics LW1200ER è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del LG Electronics LW1200ER - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso LG Electronics LW1200ER imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul LG Electronics LW1200ER ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il LG Electronics LW1200ER, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del LG Electronics LW1200ER.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il LG Electronics LW1200ER. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo LG Electronics LW1200ER insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.