Manuale d’uso / di manutenzione del prodotto SU2200RMXL3U del fabbricante APC
Vai alla pagina of 25
990-1055A, 08/01 User’s Manual English APC Smart-UPS ® 2200VA /3000VA 3U Rack M ount Uninterr uptible Pow er Supply 230VA C/120VA C.
.
1 1: S AF E T Y I NFOR MA TION Am erican Power Conversion Corporation (APC) is the leading n ational and international manu fac- turer of sta te-of-the -art uninterr upti ble p ower sup plie s, re dunda nt switches, p ower management so ft- w are, and related equi pment.
2 anesthesia ven tilators, infusion pumps, an d any other device designated as “critical” by the U.S.F.D.A. Hospital grade w iring dev ices and leakage cu rrent may be ordered as options on man y APC UPS system s, APC does not claim that units w ith this m odification are certified or listed as Hospital Grade by A PC or any oth er organization.
3 B ATTERY S AFETY This equipm ent contains potentially hazardou s voltages that m ay cause pers onal injury if handled incorrectly. This equipm ent m ust be installed and serviced only by qualified electrical service personnel. n This equipm ent contains poten tially hazardous voltages.
4 2: I NST A LLA TION The UPS has a “rack” des ign so it can be m ounted in a 19-inch (46.5 cm ) equipm ent rack. Hardw are is provi ded. U NPACKING 1. Inspect the UPS upon receipt. APC design ed robust packag ing for y our product. How ever, acci- dents an d damage m ay occu r during sh ipment.
5 5. Connect th e battery and attach th e front bezel. 6. Connect th e equipmen t and power to th e UPS. 7. Turn on th e UPS. I NSTALLIN G THE M OUNTING R AI LS IN THE R ACK Install the m ounting rails in th e rack. Directions are included w ith the rail kit.
6 3. Locate the battery m odule handle at the top of the battery f ace plate . 4. Be careful during th is step—the battery module is heavy . Pull the battery m odule handle toward y ou to slide the battery m odule out of the UPS. DO NOT pull on the battery cables or the wh ite cord.
7 C ONNECTING THE B ATTERY AND A TTACHING THE F RONT B EZEL 1. Facing the f ront of the UPS, locate the battery cables and the UPS battery connector jack to the right of th e battery m odule. 2. To connect the battery connector plug to the battery jack, push the plu g into the jack so the metal pieces inside each part are touch ing.
8 4. Turn on all conn ected equipmen t (loads). To use the UPS as a m aster ON/OFF sw itch, be sure all connected loads are switched on. The loads will n ot be p owered un til the UPS is turned on. 5. Add any optional accessories. See th e documen tation accompany ing th e accessory f or details.
9 3: O PER A TION I NDICATORS AND C ONTROLS ON T HE S MA RT -UPS The APC Un interru ptible Pow er Supply (UPS) is des igned to prev ent blackou ts, brow nouts , sags an d surges from reaching y our computer an d other valuable electronic equipmen t.
10 S ELF -T EST Automatic Self-Test The UPS performs a s elf-test au tomatically when turned on, and ev ery tw o week s thereafter (by def ault). Refer to the User Configurati on Items for details on changing the default interval. Autom atic self-test eases m aintenance requiremen ts by elimin ating the need for periodic manual self -tests.
11 Voltage Trim This LED illumin ates to indicate the UPS is co mpensatin g for a high util- ity v oltage. Voltage Boost This LED illumin ates to indicate the UPS is co mpensatin g for a low utility volta ge.
12 S MAR T -UPS R EAR P ANEL The rear panel has the input and output conn ectors, computer interface port, and default setting bu t- tons for the low battery w arning level an d voltage sensitivity in dicator.
13 To red uce UPS sensitivity , press the voltag e sensitivity button. Use a pointed object (su ch as a pen) to do so. Press th e button once to set sensitivity to reduced . Press it again to set sensitivity to low . Press the button a third time to reset normal sensitivity.
14 O N -B ATTERY O PERA TION The Smart-UP S switches to battery oper ation auto matically if the utility power fails. W hile running on-battery , an internal alarm sounds (periodic beeps). Pre ss the button (f ront panel) to silence th e UPS alarm (for the cu rrent alarm on ly).
15 4: U SER C ONFIGU RA T ION I TEM S N OTE : S ET TING T HESE ITEMS REQU IRES SOFTWA RE OR O PTIONA L H A RDWA RE . F UNCTION F ACTORY D EFAULT U SER S ELECTABL E C HOICES D ESCRIPTION Autom atic Sel.
16 N OTE : S ET TING T HESE ITEMS REQU IRES SOFTWA RE OR O PTIONA L H A RDWA RE . F UNCTION F ACTORY D EFAULT U SER S ELECTABL E C HOICES D ESCRIPTION High Transfer Point 120V Models 132 VAC 230V Mode.
17 5: S T ORAGE A ND M AINTENA NCE S TORAG E S TORAGE C ONDITIONS Store the UPS covered and flat (rack mou nt orientation) in a cool, dry location, with its batteries fully charged. Disconnect any cables connected to the computer interface port to avoid unnecessary bat- tery dr aina ge.
18 6: T RA NSPORTING Y OUR S MA RT -UPS R EMOVING THE UPS FROM THE R AC K Always DIS CONNECT T HE BATTE RY before ship ping the UPS to avoi d dam age durin g transport. (U.S. Federal Regulation requires that batteries are disconnected during shipment.
19 7: T ROUBLESHOOTING Use the chart below to solve m inor UPS installation prob lems. A lso refer to the APC web site. Con- tact APC for ass istance w ith complex UPS problem s. P ROBLEM A ND P OSSIBLE C AUS E S OLUTION UPS WILL NOT TURN ON ON button not pushe d.
20 P ROBLEM A ND P OSSIBLE C AUS E S OLUTION A LL INDICATORS ARE L IT AND THE UPS EMITS A CONSTANT BEEPING Int ernal UPS fault. Do not at tempt to use t he UPS.
21 S ERVICE If the un it requires service, do not return it to the dealer. Instead, follow these steps: 1. Review th e problems di scussed i n the Troubl eshooting section of this m anual to eliminate com - mon problems . 2. Verify that no circuit breakers are tripped.
22 8: C ONT A CT , R EGULA T OR Y , A ND W A RRA NTY I NFORMA TION C ONTACTING AP C Refer to the inform ation provided at the APC Internet site: ht t p :/ / www. a p c. c o m/ s u pport/contact R EGULATORY A GENCY A PPROVALS 230V M ODEL S This is a Class A product.
23 D ECLARA TION OF C ONFORMITY L IMITED W ARRA NTY Am erica n Po we r Convers ion (APC) w arrants its products to be f ree f rom def ects in m ateri als and w orkma nship for a period of tw o yea rs from the date of purchase .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il APC SU2200RMXL3U è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del APC SU2200RMXL3U - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso APC SU2200RMXL3U imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul APC SU2200RMXL3U ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il APC SU2200RMXL3U, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del APC SU2200RMXL3U.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il APC SU2200RMXL3U. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo APC SU2200RMXL3U insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.