APC Mod ula r Pa ne l Pr o d uc t s T he APC Modu lar Pa nel P rod uc t Su rg e Pr ot e ct iv e D e vi c es ( S P D ) are de sign ed to provide protectio n at the ser vic e entran ce, branc h pane ls or othe r cri tical l ocatio ns for today’ s ele ctri cal e quipm ent.
D A NGER H A Z ARD OF E LECTRIC SHOCK , E XPLOSION, OR ARC FL ASH · App ly ap propr iate pers onal p rot ecti ve equip ment (PPE) a nd follow s afe ele ctric al work p ractic es. See NFP A 7 0E. · Thi s equi pme nt must onl y be ins talle d and se r v iced by qu alif ie d ele ctric al pe rso nne l.
C A UTION L OSS OF SURGE PROTE CTION · During insta llati on int o an el ect ri cal s ys te m, S PD’s mu st n ot b e en er g i ze d un ti l t h e e l e c tr i c a l s ys t e m is com pletely i nstall ed, insp ected, and tested. All co nductor s must be c onne cted and f unctio nal, incl uding th e neu tral.
CONTENTS INTRODUCTI ON .............................................................................. UNPACKING A ND PRE LIM INA RY I NS PE CT IO N ............................... STORAGE ...............................................................
INTRODUCTION Thank you for choosing th e APC SurgeArrest ® PM3 or PM 4 Series Surge Pr otection Device. The APC modular Surge Protection Device (SPD) is a high-quality, high-energy su rge attenuation system that has been design ed to protect sensitive equipment from damaging tran sient voltage surges.
Proper inst allati on is im per ati ve to m ax im iz e the APC M o du la r Pa ne l SPD’s effectivene ss and pe rfor man ce . The i nst al le r sh ou ld fo ll ow t he steps outlined in this instru ction manual t o ens ure p ro pe r in st al lat ion .
The i dentif ic ation na mepl ate ( s ee Fig ure 1 ) is lo cated on the ins ide of the door/ cover . Fig ur e 1: SPD Nam ep la te E xa mp le IDE NTI FICA TI ON NA ME PL A TE S AFE T Y L A BE LS SPD LO.
Prio r t o mou nting the SPD , veri f y that the d evice h as the sa me voltag e rating as th e power distr ibutio n system in whi ch it is in stall ed by comp arin g the nam epl at e voltag e or mod el nu mber o n the SPD with the n ame plate of the el ectr ical d istrib ution e quip ment.
T he integra l switch is a se cond m ech anic al me ans for qu ali fie d maintena nce p ers onne l to isolate the entire sur ge supp ress or to ser v ice the devi ce’ s compo nents. Th e integral sw itch opens th e phas e and ne utra l conn ecti ons to the SPD for additio nal protectio n.
S YSTEM G ROUN DI NG C A UTION S YSTEM G ROUN DI NG · SPD must be i nstall ed on so lidl y ground ed power systems. · V eri f y that the se r vi ce entra nce e quip ment is b onde d to ground in acco rdanc e with al l app lica ble co des.
D ANG ER H A Z ARD OF E LECTRIC SHOCK , E XPLOSION, OR ARC FL ASH · App ly ap propr iate perso nal p rot ecti ve equip ment (PPE) a nd follow s afe ele ctri cal wor k practi ces. Se e NFP A 70E. · Thi s equi pment m ust onl y be ins talle d and s er v iced by qu alif ie d ele ctri cal p ers onne l.
N ot e: Prior to mounting the S PD , ver if y that th e devic e has the s ame vol tage rating as th e power distr ibutio n system in whi ch it is in stall ed by comp arin g the nam epl at e voltag e or mod el nu mber o n the SPD with the n ame plate of the el ectr ical d istrib ution e quip ment.
W IR ING D IAGR A M S WITH OUT I NTEG R A L DI SCO NN ECT Fig u re 3 : S i ng le - Ph as e, 3 -Wi r e, G ro un d ed Chasis Ground Chasis Ground Ø C Ø A N Customer Connections 120 kA - 240 kA Figure .
8220-0014-06 Customer Connections 320 kA - 480 kA Ø C Ø A N Customer Connections 120 kA - 240 kA Ø C Ø A BØ N W IR ING D IAGR A M S WITH I NTEG R A L DI SCO NN ECT Chasis Ground Chasis Ground F i.
The SPD disp lay pa nel sh ows t he st at us o f th e mo du les w i t h On wye and sp lit ph ase co nfi gur at io n SP D mo du les ( se e Fi gu re 7) , i f th e lef t gre en LED is n ot lit, it indic ates a loss of sup pres sion f rom li ne-to- groun d for that pha se.
Push the a lar m ena ble/ dis able b ut ton t o ena ble o r disa ble the a lar m. If the gree n ala rm LED is l it the al arm i s enab led. If the gre en a lar m LED is not lit, the al arm is d isab led. The s urge co unter disp lays the num ber of trans ient vol tage su rges si nce the cou nter was last re set.
The c ontacts are d esi gned fo r a Ma xim um voltag e of 2 4 VDC a nd a ma xi mum cur rent of 2 A . Highe r en ergy a ppli cations m ay require ad ditio nal relay im ple mentatio n outsid e the SPD .
D ANG ER H A Z ARD OF E LECTRIC SHOCK , E XPLOSION, OR ARC FL ASH · A pp ly ap propr iate perso nal p rot ecti ve equip ment (PPE) a nd follow s afe ele ctri cal wor k practi ces. Se e NFP A 70E. · Thi s equi pme nt must onl y be ins talle d and se r v iced by qu alif ie d ele ctri cal p ers onne l.
START Possible diagnostic display board failure. Replace diagnostic display panel. Is power being supplied to the SPD? Green phase LED(s) not lit. And, no Red LED(s) lit and no Alarm on. Energize SPD and verify proper connection. NO YES START YES NO Red phase LED(s) lit.
Entire contents copyright 2 008 by American Power Co nversion Corporation. A ll ri ghts reserved. Reproduction in whole or in part without permis sion is prohibited.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il APC PML3DS-A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del APC PML3DS-A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso APC PML3DS-A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul APC PML3DS-A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il APC PML3DS-A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del APC PML3DS-A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il APC PML3DS-A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo APC PML3DS-A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.