Manuale d’uso / di manutenzione del prodotto 2800HT del fabbricante Lennox Hearth Products
Vai alla pagina of 29
INSTALLATION AND OPERATION MANUAL MODEL 2800HT RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED WOOD BURNING FIREPLACE INSERT THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. READ ENTIRE MANUAL THOROUGH LY BEFORE INSTALLATION. P/N 775004M, Rev.
IMPORTANT WARNINGS CAUTION: PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FOR YOUR SAFETY, FOLLOW THE INST ALLATION, OPERATION AND MAINTENANCE INSTRUC- TIONS EXACTLY, WITHOUT DEVIATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
PAGE 3 TABLE OF CONTENTS Important Wa rnings ................................................. 2 Testing / Listing, EPA, Using this Manual ................ 3 Planning Your Inst allation ..................................... 4-7 Installati on .........
PLANNING YOUR INSTALLATION PAGE 4 QUESTIONS TO ASK LOCAL BUILDING OFFICIAL A correct installation is critical and imperative for reduc- ing fire hazards and perilous conditions that can arise when wood burning appliances are improperly installed. The installer must follow all of the manufacturer's in- structions.
PLANNING YOUR INSTALLATION PAGE 5 CLEARANCES WARNING: IT IS VERY IMPORTANT THAT YOU OBSERVE THE MINIMUM CLEARANCES. DO NOT STORE FIREWOOD WITHIN THIS CLEARANCE SPACE.
PLANNING YOUR INSTALLATION PAGE 6 FACTORY BUILT FIREPLACES (Not Approved In Canada) In the USA, this appliance is approved for installation into a listed factory built solid fuel burning fireplace (built to UL 127 or ULC S610 standards).
PLANNING YOUR INSTALLATION PAGE 7 MASONRY FIREPLACES This appliance is approved for installation into a ma- sonry fireplace built to UBC 37 or ULC S628 standards. Do not remove brick or mortar form the masonry fire- place to accommodate this appliance.
INSTALLATION PAGE 8 FIREPLACE INSTALLATION • USA only - All masonry fireplace installations re- quire a minimum positive flue connection using a block-off plate or a positive seal past the bottom of the chimney flue tile liner. In Canada, a full reline is required.
INSTALLATION PAGE 9 POWER CORD CHANGEOVER DANGER: Risk of electrical shock. Disconnect pow er before servicing appliance. Do not route pow er cord under or in front of appliance. To change the power cord from one side of insert to the other, perform the following steps: 1.
INSTALLATION PAGE 10 10. Offsets can be handled using an offset adapter (it aligns starter pipe with flue. See Offset Adapter , page 26 for ordering information).
INSTALLATION PAGE 11 SURROUND ASSEMBLY IMPORTANT: Do not face seal over chimney cooling air system on superior brand or any brand fireplace w hich is designed w ith the chimney cooling air sy stem. 13. Pull the insert slightly forward to its desired position; attach the face shield using the sur- round clips and hardware as shown.
INSTALLATION PRODUCT FEATURES AND CONTROLS PAGE 12 POSITIVE FLUE CONNECTION FOR MASONRY FIREPLACE (continued) A preferable installation is the positive flue connection (a positive seal between the flue extension and the chimney). This can be achiev ed by using a filler plate.
CARE AND OPERATION PAGE 13 GOLD DOOR The doorframe is plated with 24-karat industrial grade gold and requires curing to harden the gold. Once it is cured it will never tarnish. Prior to burning this appliance the door- frame should be cleaned thoroughly with a good window cleaning solution and a soft cloth.
CARE AND OPERATION PAGE 14 AIR DRAFT CONTROLS This appliance has two combustion air controls located under the hearth extension. The control on the left is the Start-Up Air Control.
CARE AND OPERATION PAGE 15 BLOWER SYSTEM The Blower System consists of a ON / OFF rocker switch, a variable speed blower speed control switch (rheostat) located on the right side panel, a thermally activated switch (fan disc) and 4 axial blowers. When starting a fire, leave the blower system off until the insert is thoroughly heated (approx.
FUEL MAINTENANCE PAGE 16 BURN RECOMMENDED FUEL This appliance is approved for use with wood only. Use only natural dry untreated wood (see Important Warn- ings , page 2, #10). Do not burn particleboard scraps or pressed logs using bonding agents because they can produce conditions which will deteriorate metal.
MAINTENANCE PAGE 17 DOOR GASKET A spun fiberglass gasket (3/4" [19 mm] in diameter) pro- vides the seal around the fuel door. Should this become frayed or damaged it should be replaced. Spun fiberglass "rope" gasketing can be purchased from your dealer.
MAINTENANCE PAGE 18 Cleaning – If the chimney is to be cleaned without re- moving the insert from the fireplace, the baffle plate (in the firebox) must first be removed. Chimney cleaning should only be done by a qualified chimney sweep. See following – Cleaning / Removing Baffle Plate .
TROUBLESHOOTING PAGE 19 * SMOKES OUT FUEL DOOR WHEN OPEN 1. The primary air control is closed. 2. The chimney is too cool. Set the primary air control on HIGH setting with start-up control OPEN for a few minutes before opening the fuel door. 3. Excess creosote will not only restrict your draft but it will create a risk of a creosot e fire.
TROUBLESHOOTING PAGE 20 OVERFIRING DAMAGE If the heater or chimney connec tor glows, you are overfir- ing. Other symptoms may include: Cracking, warping or burning out of components, go ld door may turn color, stove gla ss may develop a haze, which will not come off with cleaning.
SPECIFICATIONS - Model 2800HT PAGE 21 Approx. heat capacity Up to ~1800 Sq. Feet Up to ~ 550 Sq. Meters Maximum log length 18" (457 mm) Flue size 6" (152 mm) Width w / standard surround 42&q.
REPLACEMENT PARTS LIST – Model 2800HT PAGE 22 Part No. Description Door Parts G300 Door Assembly, Gold (Handle Included) 86-128 Gasket Kit, 3/4" Door Rope (Includes Adhesive) 27M81 Gasket Kit, .
REPLACEMENT PARTS LIST – Model 2800HT For the location of the nearest dealer for replacement parts, contact: Lennox Hearth Products 1110 West Taft Avenue Orange, CA 92865 PAGE 23 Part No.
COMPONENT DIAGRAMS – Model 2800HT PAGE 24 FIREBRICK (1 ¼” THICK) AIR CONTROLS FIREBOX PARTS DOOR ASSEMBLY HANDLE ASSEMBLY.
SAFETY/LISTING LABEL PAGE 25 Ca tal og # Mo de l Description (Model) 14 M78 OA2800-66 Offset adapter, 6” to 6” diameter 14M74 ZCFK-28 Zero Clearance Fireplace Kit 14M75 MFK-28 Masonry Fireplace Ki.
SAFETY/LISTING LABEL PAGE 26.
EPA LABEL PAGE 27.
Page 28 OWNERSHIP RECORDS Dealer’s Name: Dealer’s Address: City: State: Zip Code: Serial Number: Date of Purchase: Date Installed: Notes: SERVICE AND MAINTENANCE LOG Service Service Service Date T.
1110 West Taft Avenue Orange, CA 92865.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lennox Hearth Products 2800HT è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lennox Hearth Products 2800HT - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lennox Hearth Products 2800HT imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lennox Hearth Products 2800HT ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lennox Hearth Products 2800HT, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lennox Hearth Products 2800HT.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lennox Hearth Products 2800HT. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lennox Hearth Products 2800HT insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.