EPA CERTIFIED CATALYTIC WOOD BURNING FIREPLACE INSERT MODEL BV4000C P/N 775006M, Rev. J, 04/01 THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED TECHNICIAN.
IMPORTA NT WA RNINGS CA UTION: Read thi s manual thoroughly before starting ins tallation. For your sa fety, foll ow the installation, op- eration and maintenance instructions exactly without deviation. Failure to follow these instructions may result in a possible fire hazard and will void the w arranty.
PAGE 3 TA BLE OF CONTENTS Impor tant W arnings ................................................. 2 Tes ting / Listing, EPA, Using this Manual ............... 3 Planning Your Installation ...................................... 4-7 Installation ........
PLA NNING YOUR INSTA LLA TION PAGE 4 QUESTIONS TO AS K LOCA L BUILDING OFFICIA L A corr ect installation is cr itical and im perative f or reduc- ing fire hazards and perilous conditions that c an aris e when w ood burning appliances ar e im properly installed.
PLA NNING YOUR INSTA LLA TION PAGE 5 FLOOR PROTECTION This appliance requires a heat resis tant non- com bustible approved f ireplace hearth or hearth exten- sion. If a hearth ex tension is us ed it mus t be a 3/8" (m inimum ) UL approved hearth pad or equivalent.
PLA NNING YOUR INSTA LLA TION PAGE 6 CHIM NEY IN SPECT ION The existing f ireplace should be ins pected by a local fire m arshal or qualif ied installer f or adequate servic eability prior to installing this appliance .
PLA NNING YOUR INSTA LLA TION PAGE 7 FA CTORY BUILT FIREPLA CES This appliance is approved for inst allation into a listed f actor y b u i l t so l i d f u e l b u r ni n g fi re p l a ce .
INSTA LLA TION PAGE 8 FIREPLACE INSTALLA T ION BV4000C MINIM UM F IREPLA CE DIM ENSIONS Approx. m inim um Height: 21” dim ensions into f ireplace W idth: 22 ½” Depth: 16” CA TALYTIC TEMPERATURE PROBE Install temp erature prob e prior to inst alling insert .
INSTA LLA TION PAGE 9 INSTALLA T ION ST EPS 1. Rem ove all ashes f rom the fireplac e. 2. Rem ove all ma terials inside the inser t and set them aside. 3. Rem ove the three-piece s urround as sem bly (face shield) and attach insulation mater ial provided using a nonflam - m able adhesive (i.
INSTA LLA TION PAGE 10 SURROUND A SSEM BLY NOTE: Do not f ace seal over chimn ey cooling air sys tem on s uperior brand or any brand fire place which is designe d with the chimney cooli ng air sys- tem. 13. Pull the insert slightly forward to its des ired pos ition; attach the face s hield using the surr ound clips and hardware as shown.
INSTA LLA TION PAGE 11 POSITIVE FLUE CONNECTION FOR MASONRY FIRE- PLACE A Profess i onal should inspec t chimney prior to installation to determ ine if any repairs are neces sary or if a chim ney reline is neces sary. The f ireplace dam per m ust be secured in the open position.
PROCUCT FEA TURES A ND CONTROLS PAGE 12 A SH DRA WER The large as h drawer located below the fuel door is designed to mak e cleaning easier by containing the ashes in a rem ov- able drawer.
CA RE A ND OPERA TION PAGE 13 FUEL DOOR CA UTION: When opening the door, do not extend it beyond i ts normal tra vel. Overextendi ng the door to a further o pen po sition can put excessiv e stress o n hinge a rea of door and hinge pins and ma y res ult in breakage.
CA RE A ND OPERA TION PAGE 14 BREA K-IN PERIOD Your fireplace insert finish is a high tem perature paint that requires tim e and tem per ature to com pletely cure. W e rec- om mend that y ou ventilate the house during the initial burns. T he paint em its non-tox ic odors during this proces s.
CA RE A ND OPERA TION PAGE 15 BLOW ER SYST EM The Blower System c onsists of a ON/OF F r ock er switch, a variable speed blower speed control switch (rheostat) , a therm ally activated switch (fan disc ) and 2 axial blowers. W hen starting a fire, leave the blower system off until the insert is thor oughly heated (approx.
CA RE A ND OPERA TION PAGE 16 BYPA SS DA MPER CONTROL The operating handle of your by pass dam per c ontrol is lo- cated on the fr ont of the stove flue collar . By moving the by- pass dam per c ontrol, the operator c an route the fire either through the catalytic com bus tor ( pushed in) or direc tly up the flue (pulled out).
MA INTENA NCE PAGE 17 BURN RECOMM ENDED FUEL This appliance is approved f or us e with natural dr y wood only . Burning mater ials other than natural wood will shorten the life of the catalytic com bustor.
MA INTENA NCE PAGE 18 DOOR /GLASS GA SKET AND A SH DUMP G A SKET A 3/4" spun fiberglas s gask et provides the seal ar ound the fuel door and a flat spun f iberglass rope gask et (1/8” x 1”) pr ovides the seal around the glas s. A cer awool pad (4 1/4” x 4 1/4” x 1/2” ) provides the seal for the ash dum p cover.
MA INTENA NCE PAGE 19 CA TALYTIC COMBUSTO R This appliance has been designed with a catalytic com - bustor, whic h will im prove its over all perf orm anc e. Re- m oving the com bustor as sem bly for cleaning and rein- stallation is sim ple and convenient.
TROUBLESHOOTING PAGE 20 * S MOKES OU T F UEL DO OR W HEN OPEN 1. The pr im ary air control is clos ed. 2. The chim ney is too cool. Set the prim ary air control on "HIGH" with the by pass dam per control "OPEN" for a f ew minutes before opening the f uel door.
TROUBLESHOOTING PAGE 21 CA TALYST PLUGGING 1. Burning m aterials that produce a lot of char and f ly as h. Do not burn materials such as garbage, gift wrap, c ard- board, etc. 2. Burning wet pitchy w oods or burning large loads of sm all diam eter wood wi th the combus tor in the oper ation pos i- tion (without light-off tak ing place).
SPECIFICA TIONS - Model BV4000C PAGE 22 A pprox. sq. ft h e a t ca p ac i t y up to ~ 2000 Sq . Ft. Maximum log length 18" Flue size 6" Width w/standard sur round 42" Width at fireplace o pening 22.
REPLA CEMENT PA RTS LIST – Model BV4000C For the lo cation of the nearest dealer for replacem ent part s, contact: Lennox Hear th Products 1110 West T aft Avenue Orange, W A 92865 PAGE 23 DOOR PARTS.
COMPONENT DIA GRA MS – Model BV4000C PAGE 24 DA M PER ASSEMBLY CA TALYTIC/DA M PER COM PONENTS PRIMARY A IR CONTROL DRAFT MODULE (PA RT /CA TALOG #11493) DOOR ASSEMBLY ( PA RT/CATA LOG #G3000) HA ND.
OPTIONA L A CCESSORIES - Model BV4000C For the lo cation of the nearest Dealer f or opt ional parts, co ntact: Lennox Hear th Products 1110 West T aft Avenue Orange, CA 92865 PAGE 25 Accessories C at .
SA FETY LISTING LA BEL / EPA LA BEL PAGE 26.
SERVICE A ND MA INTENA NCE LOG Service Service Service Date Technician Descript ion PAGE 27.
1110 West Taft A v enue Orange, CA 92865.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Lennox BV4000C è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Lennox BV4000C - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Lennox BV4000C imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Lennox BV4000C ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Lennox BV4000C, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Lennox BV4000C.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Lennox BV4000C. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Lennox BV4000C insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.