Smart-UPS ® Model 600 User’ s Manual Te st.
Important safety instructions! Please r ead this manual! V euillez lir e ce manuel! Bitte lesen Sie dieses Anleitungshandbuch! ¡Se ruega leer este manual de instrucciones! This manual pr ovides safety , installation, and operating instructions that will help you get the fullest performance and service life that the UPS has to of fer .
1 T able of Contents 1.0 Intr oduction .................................................................... 3 1.1 Overview .......................................................................................................... 3 1.2 SmartBoost ....
2 8.0 Storing the UPS ............................................................. 35 8.1 Storage conditions ........................................................................................ 35 8.2 Extended storage ............................
3 1.0 Intr oduction 1.1 Overview This equipment is a high-performance, line-interactive, uninterr uptible power source (UPS) designed to provide clean, r eliable, AC power to computer loads. The UPS’s line-interactive cir cuit topology (see figure below) of fers excellent efficiency , on-line voltage regulation, and fast utility fault response.
4 1.2 SmartBoost SmartBoost allows continuous, on-line operation during extended br own- outs or low line voltage conditions. The UPS compensates for r educed line voltage by boosting the load voltage to 12% above the input. This enhances UPS r eliability because the battery is saved for complete utility failure .
5 2.0 Safety! ENGLISH Caution! CAUTION! ■ T o r educe the risk of electric shock, disconnect the Uninterruptible Power Source fr om the mains before installing computer interface signal cable (when used). Reconnect the power cor d only after all signalling interconnections have been made.
6 2.0 Sécurité! FRANÇAIS Attention! A TTENTION! ■ Pour réduire le risque d’électrocution, débranchez la prise principale de la sour ce d’alimentation permanente (Uninterr uptible Power Sour ce), avant d’installer le câble d’interface allant à l’or dinateur (si utilisé).
7 2.0 Sicherheit! DEUTSCH V orsicht! VORSICHT! ■ Um die Gefahr eines elektrischen Schlages auf ein Minimum zu r eduzieren, die unterbr echungsfr eie Stromversorgung vom Stromnetz tr ennen, bevor ggf. ein Computer -Schnittstellensignalkabel angeschlossen wir d.
8 2.0 ¡Seguridad! ESP AÑOL ¡Atencion! ¡A TENCION! ■ Para reducir el riesgo de descarga eléctrica, desconecte de la r ed la Fuente de ener gía ininterrumpible antes de instalar el cable de señalización de interfaz de la computadora (si se usa).
9 3.0 Pr esentation 3.1 600V A UPS—100 and 120 V ac versions Rear view NEMA 5-15R r eceptacles Computer Interface port See Sec. 6.4 UPS enable switch see Sec. 4.3 Site wir e fault light see Sec. 4.5 Option switches see Sec. 5.5 IEC 320 inlet Cir cuit breaker Display featur es see Section 5.
10 3.0 Pr esentation 3.2 600V A UPS—220/230/240 V ac version Rear view IEC 320 output couplers Compute Interface port See Sec. 6.4 IEC 320 inlet Cir cuit breaker Front view Display features see Section 5.1 T est button see Sec. 5.1.8 Alarm disable button See Sec.
11 4.0 Installation 4.1 Receiving inspection Once you r emove the UPS fr om its shipping container , inspect it for dam- age that may have occurred while in transit.
12 4.3 Connect UPS to service and enable 4.3.1 Connect UPS to service ■ 100, 120 V ac versions Plug the UPS into a two-pole, thr ee-wire gr ounding receptacle only . A void the use of extension cor ds and adapter plugs. ■ 220/230/240 V ac version The 220/230/240 V ac version UPS is not furnished with an input line cor d.
13 4.3.2 Enable UPS Move the UPS Enable switch to the on ( I ) position. When shipped, this switch is in the of f position to pr event accidental activation of the UPS. The batteries will not appr eciably discharge if this switch is left on. Allow the UPS to char ge its battery for at least 8 hours before use.
14 4.0 Installation 4.6 Switch on load equipment If you leave the load equipment switched on, you can use the UPS’s power on button as a master system on/of f switch. 4.7 Switch on the UPS The UPS and your loads become ener gized when you pr ess and hold the power on button for a second.
15 5.0 Operation 5.1 Display featur es 5.1.1 On Line indicator The On Line indicator lights when the load is being supplied conditioned power fr om the utility service.
16 5.1.6 Power on button The power on button turns on the UPS and ener gizes the load. Note that the UPS must be enabled (see Sec. 4.3.2). The UPS’s battery char ger is always active as long as the UPS is plugged in. 5.1.7 Power standby button The power standby button turns of f the UPS and deenergizes the load.
17 5.2 Output Power bar graph When you pr ess and hold the T est button, the LED indicators display a bar graph of the power being drawn by the load connected to the UPS. 5.0 Operation This example shows that the equipment plugged into the UPS is drawing between 264 and 330 W atts (400–500 V A for typical computer equipment).
18 5.4 Audible alarms The UPS featur es an audible alarm that beeps to indicate certain conditions (see Secs. 5.4.1–5.4.4). 5.4.1 On-battery alarm The UPS emits four short beeps every 30 seconds when the UPS is operat- ing on battery power . Y ou may silence this alarm by pr essing the alarm disable button (see Sec.
19 5.0 Operation 5.5 Option switches The UPS has a set of four DIP switches on the rear panel which allow you to configur e several options (see Secs. 5.5.1–5.5.4). 0 ( o f f ) I ( o n ) 1 2 3 4 Note: Y ou can set option switches at any time, and the effect is immediate.
20 5.5.2 Option Switch 2 Option Switch 2 functions dif ferently for differ ent versions of the UPS. ■ 100 V ac version No function; not used. ■ 120 V ac version The UPS’s factory-set input voltage limits for on-line and SmartBoost operation ar e centered on the nominal input voltage of 120 V ac (see also Sec.
21 5.6 Extended capabilities Sections 5.6.1 thr ough 5.6.4 briefly describe the UPS’s extended capabili- ties—advanced functions accessed using a computer r unning optional PowerDoctor or PowerChute plus UPS monitoring software. Refer to the monitoring softwar e documentation for more information on these func- tions.
22 ■ Output power The UPS continuously monitors the power consumed by the load. The value given is a per centage of the full load rating of the UPS. This informa- tion may be logged using UPS monitoring softwar e, plotted using a spread- sheet application, and used to track load usage over extended periods.
23 5.6.4 Operation customizing Y ou may configure many UPS operations for specific applications. T o use the customizing featur es of the UPS, you must set all option switches to the on ( I ) position. The functions or dinarily controlled by the switches ar e duplicated in the UPS monitoring softwar e.
24 ■ Audible alarm operation The UPS’s audible alarm beeps four times every 30 seconds during on- battery operation. The alarm beeps continuously when low-battery condi- tions ar e reached.
25 6.0 UPS Monitoring 6.1 Overview A UPS system alone pr ovides excellent protection fr om brief power pro b- lems. During an extended power outage, an unattended computer system will eventually shut down because of battery capacity exhaustion.
26 6.4 Computer interface port The computer interface port is diagramed below . Those with technical abilities wishing to use this port in a special application should be awar e of the following limitations and capabilities of the interface.
27 7.0 Difficulty ENGLISH Caution! CAUTION! ■ This Uninterr uptible Power Sour ce contains potentially hazardous voltages. Do not attempt to disassemble the unit. The unit contains no user serviceable parts. Repairs are performed only by factory trained service personnel.
28 7.0 Difficulté FRANÇAIS Attention! A TTENTION! ■ Cette source d’alimentation permanente (UPS) contient des cir cuits haute tension présentant un danger . Ne jamais essayer de le démonter . Il n’y a aucun composant qui puisse êtr e réparé par l’utilisateur .
29 7.0 Schwierigkeit DEUTSCH V orsicht! VORSICHT! ■ Im Inneren dieser unterbrechungsfr eien Stromversor gung herrschen potentiell gefährliche Spannungen. Nicht versuchen, das Gerät zu öffnen. Es enthält keine vom Benutzer r eparierbaren T eile. Reparaturen dürfen nur von ausgebildetem Kundendienstpersonal dur chgeführt werden.
30 7.0 Dificultad ESP AÑOL ¡Atencion! ¡A TENCION! ■ Esta Fuente de energía ininterrumpible contiene niveles de voltaje peligr osos en potencia. No intente desarmar la unidad, pues no contiene piezas que puedan ser r eparadas por el usuario.
31 7.0 Difficulty 7.1 T r oubleshooting PROBLEM: UPS will not turn on Possible cause: UPS Enable switch is in the off position or the power on switch is not pressed. Solution: T urn on the r ear panel UPS Enable switch. Press fr ont- panel power on switch to energize UPS and loads.
32 7.1 T 7.1 T 7.1 T 7.1 T 7.1 T r r r r r oubleshooting oubleshooting oubleshooting oubleshooting oubleshooting (continued) PROBLEM: UPS does not provide expected back up time. Possible cause: UPS’s battery is weak from recent outage or wear . Solution: The battery needs recharging after an extended outage.
33 7.0 Difficulty 7.2 Batter y replacement check The UPS automatically performs a battery test at startup and again every 14 days. This test briefly loads the batteries and can detect a weak battery befor e it is put into service during a power failure.
34 7.0 Difficulty 7.3 Obtaining service The tr oubleshooting chart in Section 7.1 covers most of the dif ficulties that you may encounter under conditions other than a failur e of the UPS itself. For pr oblems not cover ed in the chart, follow the procedur e outlined below .
35 8.0 Storing the UPS 8.1 Storage conditions When you stor e the UPS, cover it and keep it upright in a cool, dry loca- tion. Store the UPS with its battery fully-char ged.
36 9.0 Specifications 9.1 Input UPS version (V ac): 100 120 220/230/240 Nominal input voltage (V ac): single phase 100 120 230 Nominal input frequency: 50 or 60 Hz. Internally selected by micr opr ocessor . Input protection: 8 Amp 7 Amp 5 Amp Push-to-r eset circuit br eaker .
37 9.4 Battery and char ger UPS version (V ac): 100 120 220/230/240 Battery type: Spill proof, maintenance fr ee sealed lead-calcium. T ypical battery life: 3 to 6 years. Battery life dependent on number of dischar ges and ambient temperatur e. Low battery signaling: Continuous visual and audible alarm 2 minutes before shutdown.
38 9.7 Physical Size (H ´ W ´ D): 6.6 ´ 4.7 ´ 13.8 in. (17 ´ 12 ´ 35 cm) W eight: 28 lbs (12.7 kg) Shipping weight: 30 lbs (13.6 kg) 9.8 Appr ovals Safety approvals: UL per 1778, CSA per C22.2, TUV per IEC 950. EMC verification: FCC/DOC Class B certified; VCCI Class 2 compli- ance; VDE/EN55022 Class B verified.
39 9.9 T ypical r un times versus load Load Run T im e T ypical computer (VA † ) (minutes ‡ ) equivalents 250 26 Apple Macintosh IIci w/color monitor Compaq Presario 400/600 Series w/monitor 300 20 Gateway 486/33 tower w/VGA monitor Apple Macintosh IIci w/19-in.
40 Notes.
Limited W a rranty American Power Conversion (APC) warrants its products to be fr ee from defects in materials and workmanship for a period of two years fr om the date of purchase. Its obligation under this warranty is limited to r epairing or r eplacing, at its own sole option, any such defective products.
( PHONE (800) 800-4272 in USA & Canada (401) 789-5735 worldwide * MAILING American Power Conversion 132 Fairgr ounds Road P .O. Box 278 West Kingston, Rhode Island 02892 USA ( PHONE (+33) 1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il APC 600 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del APC 600 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso APC 600 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul APC 600 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il APC 600, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del APC 600.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il APC 600. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo APC 600 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.