INSTRUCTION MANUAL PORTABLE SLIT-LAMP Kowa SL-15.
P - 1 Warning Warning Warning Caution Caution INTR ODUCTION Accept our congratulations on your purchase of Kowa's Portable Slit-lamp. This manual provides a description of the operating procedure of this unit along with important precautions to be observed during its use.
P - 2 WARNING WARNING Obligatory If any abnormal smell or sound, or overheating or smoke should be detected, turn off the instrument immediately and then unplug it. If it should continue in use, a fire may break out on the instrument resulting in its malfunctioning.
P - 3 Caution Caution Prohibitory For unplugging from the outlet, pull the power cord out of it while holding the plug with your hands. Otherwise, there may occur a fire or electrical shock. Do not put in, or pull out of, the outlet, the plug with your wet hands to avoid electrical shock.
P - 4 Operational precautions f or saf ety and accident prev ention in use of batter y Kowa's SL-15 uses a lithium ion battery in its power pack. Always take the following precautions to avoid a serious injury or burn caused by fluid leakage, heat build-up, ignition and explosion as well as occurrence of a fire.
P - 5 Oper a tional pr ecautions ● The instrument should be installed and/or stored in a dust free place free from high temperatures, high humidity and direct sunlight.
P - 6 Operational Considerations for Hospital Grade Electrical Equipment (Saf ety and Accident Prev ention) This section describes general precautions concerning the use of medical electrical instrument based on Notification No. 495 of the Pharmaceutical Affairs Bureau of the Ministry of Health and Welfare dated June 1, 1972.
P - 7 Power cable:1 pc. Fuse:2 pc. Lump:1 pc Dust cover:1 pc. Instruction manual:1 pc. Accessories.
P - 8 Contents Introduction ............................................................................................................. 1 Operational Considerations for Safety and Accident Prevention ............................ 1 Precautions in use of battery (safety/accident prevention Operational precautions .
Name and function of eac h par t 1. P - 9 Main unit (slit-lamp) 1 Prism box For adjusting the eye-to-eye distance, bend and stretch this part both ways. 2 Ocular With rubber attachment for compen- sating the diopter of the laterally bi- ased eye either way .
P - 10 1. Name and function of eac h par t Picture of power source as viewed from above (The figure seen from the top) F Main unit's charger indicating lamp When the power pack inside of the main unit, which is set at the main unit's charger , is being charged, the indicating lamp comes on to emit orange light.
P - 11 1. Name and function of each part Battery (power pack) M Battery connector When it is set at the main unit or power pack charger , set the battery connector such that it can be in proper contact with the charger . Option (forehead rest) N Forehead rest Fix the forehead rest such that the examined patient's forehead can rest against it.
2. Pr epar ation P - 12 IN 1 Open the grip cover 2 Mount the power pack 3 Close the grip cover 2-1 Setting Place the power source on a stable table and connect the power cable to the inlet on the back of the power source.
P - 13 2-3 Charging a single power pack independently of the main unit 2-3 Char ging a single po w er pack independentl y of the main unit 1 Insert the power pack deep into the power pack charger while holding it in the direction of photo. 2 Make sure the power pack charger indicating lamp is on emitting orange light.
P - 14 2. Prepar ation Caution Caution Caution 2-5 Char ge time and ser vice time of pow er pac k 1 The reference charge time spent in fully charging an exhausted battery at a room temperature of 25˚.
P - 15 3. Ho w to use 2 Adjusting ocular diopter value 3-1 How to hold the slit-lamp 1 Hold the slit-lamp's main body . securely grabbing its grip by your right (or left) hand. 2 Place the other hand's thumb on the side of upper-end of the slit-lamp's main body .
P - 16 3. Ho w to use 3-3 How to use magnifying pow er select le v er , slit-disk and filter-disk. 1 T urn the magnifying power select lever clockwise as indicated by arrow-head to select a magnifying power of 16. T urn it counterclockwise to select a magnifying power of 10.
P - 17 4. T r oubleshooting This section describes how to take action against any irregularity which occurred on the instrument. If any irregularity should occur on the instrument, check if the following faults are observed, before contacting Kowa's dealer where you purchased the instrument for repair .
P - 18 5. Maintenance and inspection Caution Caution Caution 5-1 Dail y inspection 1 If you do not operate the instrument any longer for the day , be sure to turn off the power switch and put a cover on it. 2 Care must be used to keep the objective lens free from dust and dirt, fingerprints, tear-drops and so forth.
P - 19 Caution Caution 5-3 Replacing fuse 5-3 R eplacing fuse 1 With the power switch turned off, unplug the power cable from the outlet. 2 Unscrew the power source's fuse holder cover by turning minus (-) screw driver counterclockwise to take out the fuse from within.
P - 20 6. Specifica tions Main unit (slit-lamp) [Microscope] Type : Binocular-stereoscopic-orthoscopic microscope Inward angle : 13 ˚ Magnifying power : 10/16 Objective lens' working distance : .
Printed in Japan SL 150 V1.1 E 030701 MS Printed on recycled paper. 20001 So. Vermont Ave. Torrance, CA 90502, U.S.A. Phone: 1(310) 327-1913 Facsimile : 1(310) 327-4177 Immermannstrasse 65A 40210 Düsseldorf F.R. Germany Phone: 49(211) 35-3444/45/46 Facsimile: 49(211) 161952 Life Science Division No.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Kowa SL-15 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Kowa SL-15 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Kowa SL-15 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Kowa SL-15 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Kowa SL-15, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Kowa SL-15.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Kowa SL-15. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Kowa SL-15 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.