WA TER FIL TRA TION SY STEM UF-420/440 Series Owner ’ s Man ual P/N 1010827 Rev .D 04/06 MANUF ACTURING NUMBERS: 9700440 9700442 9700443 9700450 9700452 9700453.
UF SERIES W A TER FIL TRA TION SYSTEM 2 P/N 1010827 Rev . D 04/06 General Antunes Filtration T echnologies, a Division of A.J. Antunes & Company , has partnered with compa- nies from around the globe to produce the UF-Series water filtration systems.
UF SERIES W A TER FIL TRA TION SYSTEM 3 P/N 1010827 Rev . D 04/06 Purchased From: Date of Purchase: Model No.: Serial No.: Mfg. No.: Service/T echnical Assistance If you experience any problems with t.
UF SERIES W A TER FIL TRA TION SYSTEM 4 P/N 1010827 Rev . D 04/06 Protect from becoming dry If the membrane dries out, irreversible damage to the membrane may result.
UF SERIES W A TER FIL TRA TION SYSTEM 5 P/N 1010827 Rev . D 04/06 Inlet W ater Pressure (psi) Inlet T urbidity (NTU) Required Additional Equipment Installed W ater Use (Gallons Per Day) Flush Program .
UF SERIES W A TER FIL TRA TION SYSTEM 6 P/N 1010827 Rev . D 04/06 SPECIFICA TIONS Electrical Ratings CAUTION All electrical connections must be in accordance with local electrical codes and any other applicable codes. W ARNING ELECTRICAL SHOCK HAZARD.
UF SERIES W A TER FIL TRA TION SYSTEM 7 P/N 1010827 Rev . D 04/06 Dimensions Unit A Width (inches) B Depth (inches) C Height (inches) Operating Weight (w/water) (lbs) UF-420 6-1/16 14-7/8 33-7/8 30 UF-440 6-1/16 14-27/32 53-17/32 51 A B C Figure 1.
UF SERIES W A TER FIL TRA TION SYSTEM 8 P/N 1010827 Rev . D 04/06 Unpacking 1. Remove the system and all packing materials from the shipping carton. 2. Remove all packing materials and protective cov- erings from the system 3. Remove the information packet.
UF SERIES W A TER FIL TRA TION SYSTEM 9 P/N 1010827 Rev . D 04/06 INST ALLA TION (continued) PERMEA TE LINE PLUMBING T o ensure the highest quality and safest water , it is recommended that a check valve (to prevent backflow) is installed in the water line after the permeate connec- tion.
UF SERIES W A TER FIL TRA TION SYSTEM 10 P/N 1010827 Rev . D 04/06 CAUTION Ingesting the protective solution may cause irrita- tion of the gastrointestinal tract, colic, diarrhea, or other similar symptoms 1. Plug the power cord into the appropriate electrical outlet.
UF SERIES W A TER FIL TRA TION SYSTEM 1 1 P/N 1010827 Rev . D 04/06 Figure 4. Proper Draining 2” (5.1 cm) minimum 2” (5.1 cm) minimum Floor Drain Secure End Drain Line from System Drain Line from System Secure End Drain Standpipe INST ALLA TION (continued) OPERA TION Figure 5.
UF SERIES W A TER FIL TRA TION SYSTEM 12 P/N 1010827 Rev . D 04/06 OPERA TION (continued) Programming T imer During Startup NOTE: Once the UF unit is powered up, the LED display cycles through the default or current settings: Flush Duration (Fd) and its setting will be followed by Flush Interval (Fi) and its settings.
UF SERIES W A TER FIL TRA TION SYSTEM 13 P/N 1010827 Rev . D 04/06 OPERA TION (continued) START START TO SET FD - FLUSH DURA TION MODE 1. Press and hold the Start button for four seconds. Release button, LED will display Fd . 2. When Fd is displayed (Figure 12), press and release the Start button to view the current setting 3.
UF SERIES W A TER FIL TRA TION SYSTEM 14 P/N 1010827 Rev . D 04/06 START Figure 14. Manual Flush MAINTENANCE Changing the Cartridges While the filtration system is designed for long life, eventually the cartridges will need to be replaced. 1. Open the faucet or tap closest downstream to the filtration system.
UF SERIES W A TER FIL TRA TION SYSTEM 15 P/N 1010827 Rev . D 04/06 TROUBLESHOOTING Problem Possible Cause Corrective Action Unit does not have power . The power cord is not correctly plugged in. Plug power cord in correctly . The Control Display is blank.
UF SERIES W A TER FIL TRA TION SYSTEM 16 P/N 1010827 Rev . D 04/06 REPLACEMENT P ARTS UF-420/440 1 7000432 T imer , 120V (For Mfg. #s 1 9700440 & 9700450) 7000433 T imer , 230V (For Mfg.
UF SERIES W A TER FIL TRA TION SYSTEM 17 P/N 1010827 Rev . D 04/06 REPLACEMENT P ARTS UF-420/440 (continued) 14 6 13 5 26 1 2 15 17 17 25 23 19 20 21 22 28 3 4 8 18 24 16 16 18 7 32 29 30 31 9 10 29 2.
LIMITED W ARRANTY Equipment manufactured by Antunes Filtration T echnologies, Division of A.J. Antunes & Co. has been constructed of the finest materials available and manufactured to high quality standards.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Antunes, AJ UF-420/440 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Antunes, AJ UF-420/440 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Antunes, AJ UF-420/440 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Antunes, AJ UF-420/440 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Antunes, AJ UF-420/440, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Antunes, AJ UF-420/440.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Antunes, AJ UF-420/440. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Antunes, AJ UF-420/440 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.