Manuale d’uso / di manutenzione del prodotto 90 del fabbricante Anton/Bauer
Vai alla pagina of 20
® BATTERY SYSTEM DIONIC ® 90 lithium ion Digital Battery OWNER’S MANUAL.
TABLE OF CONTENT S IMPORTANT READ AND UNDERST AND THIS MANUAL BEFORE OPER ATION .................................................................... 1 INTRODUCTION .............................................................................. 2 FEATURES .
1 IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE OPERATION The InterActive 2000 Dionic 90 battery lithium ion chemistry delivers a higher power to weight ratio than NiCd & NiMH. However, all lithium ion batteries have more sensitive char ging and discharging parameters and require longer charge times (2-5 hours).
2 INTRODUCTION The development of this new DIONIC 9 0 battery sy stem has been made possible through the incorporation of the pioneering InterActive technology of the Anton/Bauer Digital system with the very latest lithium ion cell formulations.
3 FEATURES 1. Microprocessor Fuel Computer - Accurately monitors the energy in the battery with programs that take into account battery age, self discharge, charge/discharge rate, operating conditions and previously experienced charge/discharge cycles.
4 CHARGING DIONIC 90 BATTERIES • DO NOT ATTEMPT TO CHARGE THIS BATTERY WITH ANY CHARGER OTHER THAN THE ANT ON/BAUER InterActive 2000 OR T SERIES CHARGERS SPECIFIED IN THIS MANUAL. • Allow the battery to reach a steady green (LifeSaver ® ) mode before using for the first time.
5 NOMINAL CHARGE TIMES FOR DIONIC 90 Charge Lev el LED Indicators 90% Flashing Green 100% Steady Green Dual 2722 (2 batteries simultaneously) 2hrs. 3hrs. InterActive 2000 PowerCharger (Quad/Dual – 2702/2701/2700) (Quad/Dual – 2401/2400) 2 hrs. 3 hrs.
6 The DIONIC 90 features an all NEW “RealTime” LCD display providing on-the-fly remaining run time estimates in 15 minute increments as well as simultaneously providing remaining capacity information using the traditional “Fuel Gauge” approach.
7 -The large numbers 1, 2 or 3 indicate remaining hours under current load (only one number will display at any one time) -The pie chart numbers ( 15, 30, 45, or 60) indicate remaining minutes under current load.
8 If the SIDE BARS (only) flash AND other icons are lit and not flashing, this indicates the battery has requested to be fully charged and discharged in order to update its “learned capacity”. This “learning” should typically occur during normal equipment operation.
9 RealTime Display Indications • When the DIONIC battery is being charged remaining runtime is not displayed. • Remaining run time is calculated using the present available battery capacity and a constantly updated accurate measurement of the present load on the battery.
10 • When the battery is completely discharged the LCD will flash the 15 minute icon and the ‘RES’ bar until the battery is returned to a charger. • If the protection electronics detect a low battery voltage condition (any one cell reaches roughly 2.
11 OPERATING GUIDELINES 1. Keep batteries cool or at room temperatures whenever possible. Sustained elevated temperatures are the primary reason for premature failure of lithium ion batteries: a. Charging - Charge batteries at room temperature. In warm climates keep chargers in air conditioned rooms for best performance.
12 4. Low voltage batteries can also be caused by allowing batteries to remain off the charger for extended periods causing the LCD display to be blank, indicating that the electronic circuitry has removed all load from the battery cells – including the display.
13 SERVICE In the event a DIONIC 90 battery fails to deliver acceptable performance, it must be returned to the Anton/Bauer. No ot her facility is qualified and equipped to service the InterActive 2000 DIONIC 90 ba tteries and calibrate the electronic components and sensors.
14 PRECAUTIONS 1. Do not expose this battery to high temperatures (above 50°C/120°F). This includes storage in direct sunlight , in cars in hot weather, or in close proximi ty to heating devices. This may cause electrolyte leakage, impaired p erformance and shortening of ba ttery service life.
15 DIONIC 90 BATTERY SPECIFICATIONS OUTPUT VOLTAGE 14.4v Nominal 12.4 ~ 16.8v Operating CAPA CITY (CELL CAPA CITY) 90 WH Nominal (6.3 AH Rated) FUSE Internal 8amp RECOMMENDED OPERAT ION 15 - 50 watts 1 (MAXIMUM DISCHARGE RATE) (90 watts) 2 TYPICAL RUN-TIME @ 20w - 4 ½ hrs.
16 LIMITED WARRANTY This warr anty for the battery produc t specified in this doc ument (“ Product”) is gi ven by Anton/Bauer, Inc. (“A n ton/B auer”), 14 Progress Driv e, Shelton, Connecticut 06484.
17 Dangerous Goods Regulations 49C FR Parts 100-185, Air Transport Association (IATA) and the International Civil Aviation Organization (ICAO) regulations a pply to all lithium ion battery transport.
7595-0243 Rev M The power behind the best cameras capturing the best images in the world. sm The following are trademarks of Anton/Bauer, Inc.: ACS, ADM, All Chem, Anton/Bauer, Anton/Bauer logo and pa.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Anton/Bauer 90 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Anton/Bauer 90 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Anton/Bauer 90 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Anton/Bauer 90 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Anton/Bauer 90, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Anton/Bauer 90.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Anton/Bauer 90. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Anton/Bauer 90 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.