OWNER'S MANUAL MODEL NO. UltraFilter 300 625.384720 UltraFilter 500 625.384750 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. If you have questions when installing, operating or maintaining your reverse osmosis system, call this toll-free number.
- WARRANTY- _ t t t t t t t t t t t t t t t t t t t t t t t t t t t t t _ FULL WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM I I I (except filter cartridges and R.
- TABLE OF CONTENTS - Where To Install the RO System ........ 4 Tools and Materials Needed ........... 4 Installation Steps .................... 5- 9 Cold Water Supply .................. 5 Drain Adapter ..................... 6 Faucet .................
- WHERE TO INSTALL THE RO SYSTEM - The RO assembly and storage tank is designed for installation under the sink, usually in the kitchen or bathroom. The RO assembly mounts on a wall sur- face, or can lay on the cabinet floor next to the storage tank. Hanger washers and wood screws are included for cabinet wall mounting.
- STEP 1: INSTALL COLD WATER SUPPLY FITTING - Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. The fitting must provide a leak-tight connection to the RO 1/4" tubing (see FIG. 8, page 8). A typical connection using the included water supply fitting is shown in FIG.
- STEP 2: INSTALL DRAIN ADAPTER - • Note: Running the drain tubing directly to a floor drain, sump, standpipe, laundry tub, etc., as shown on page 17, is preferred. However, if that is not pos- sible or practical, the included drain adapter installs in the sink drain pipe, always above or ahead of the p-trap (FIG.
- STEP 3: INSTALL FAUCET (cont.)- ..* SEM.LEF*UCET [ FIG. 6 ] 1. Remove the large blue nut from the faucet threads. 2. Slide the three attached tubes and the telephone style wire (monitored models only) through the sink or countertop hole, aligning gasket under faucet base.
- STEP 5: INSTALL STORAGE TANK, MAKE REMAINING TUBING CONNECTIONS - 1. CONNECT DRAIN TUBING, FAUCET TO DRAIN ADAPTER: Referring to FIG. 8, run the loose section of black 3/8" tubing from the faucet to the drain adapter, with a black collet, installed on page 6.
- STEP 6: SANITIZING, PRESSURE TESTING & PURGING - SANITIZING Sanitizing is recommended upon installation of the RO system, and after servicing inner parts. It is im- portant for the service person to have clean hands while handling inner parts of the system.
- HOW YOUR REVERSE OSMOSIS SYSTEM WORKS - PREFILTER Water from the cold supply pipe enters the RO as- sembly prefilter first (FIG. 8, page 8, and schematic, page 11). The prefilter has a replaceable sediment cartridge with activated carbon in its composition.
- HOW YOUR REVERSE OSMOSIS SYSTEM WORKS - REVERSE OSMOSIS WATER FLOW SCHEMATIC ! PRODUGq- WATER FAUCET _ir 9_p Y gra_viLy drain ! WATER IN 11 Problems, Questions? Call 1-800-426-9345 Kenmore Water Lin.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - To keep your reverse osmosis system operating and producing higil quality" water, you must make sure supply water is Nways within the lhnits shown in the specifications. Good supply water helps to assure longer Fife from the RO membrane cartridge, prefilter and postfilter cartridges.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - 2. Remove (turn to the left) the sump from the filter head, Be careful...the sump is full of water, 3. Remove mid disc_d the RO c_tridge in a proper manner. Ftush the hlsides of the sump with fresh wa- ter. Do not lose the large o-ring seals.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - TUBING CONNECTION (continued) AUTOMATIC SHUTOFF SERVICE To Disconnect Tubing: Push the collet inward and hold with a finger while pulling the tubing out. FIG. 11-A] cut tubing _uare L 1 I I I end of tubing round and smooth, with no cutS, nicks or flat spots Tubing correctly cut and connected oollet _.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - REVERSE OSMOSIS SYSTEM CARE GUIDE MODEL NOs. 625.384720 & 625.384750 1. AT LEAST every 6 months, replace the prefilter and postfilter cartridges or when yellow LED flashes.
- DIMENSIONS and SPECIFICATIONS - 15 _ 13" Supply water pressure limits ........................ 40 - 100 psi Supply water temperature limits ..................... 40 - 100 "F Maximum total dissolved soiids (TDS) ............... 2000 ppm Maximum water hardness @ 6.
- REMOTE LOCATION FOR REVERSE OSMOSIS SYSTEM - REMOTE RO INSTALLATION (storage tank not shown) Possible remote locations for the RO nearby the kitchen or bathroom sink include; (1) a basement area underneath the sink, and (2) an adjacent room or closet.
- REPAIR PARTS - Kenmore Reverse Osmosis Drinking Water System, Model Nos. 625.384720 & 625.384750 23 9 _ 8 24 / M_ni[old Housing PUSH - IN FITTINGS (_) 114" e_318 20 Z Q) DRAIN 19 22 x r I .
- REPAIR PARTS - Kenmore Reverse Osmosis Drinking Water System, Key Part Description of Part No. Number 1 7221128 Sump (3 req.) 2 7223633 O-Ring, 2-1/4" x 2-1/2" (3 req.) 3 9006062 Screw (2 req.) 4 9041700 Hanger Washer (2 req.) 5 7234210 Paddtewheel & O-Ring Kit, 625.
OWNER'S MANUAL MODEL NO. UltraFilter 300 625.384720 UltraFilter 500 625.384750 The model number of your reverse osmosis system is found on the rating decal.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Kenmore ULTRAFILTER 300 625.384720 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Kenmore ULTRAFILTER 300 625.384720 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Kenmore ULTRAFILTER 300 625.384720 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Kenmore ULTRAFILTER 300 625.384720 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Kenmore ULTRAFILTER 300 625.384720, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Kenmore ULTRAFILTER 300 625.384720.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Kenmore ULTRAFILTER 300 625.384720. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Kenmore ULTRAFILTER 300 625.384720 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.