CONNECTION DIAGRAM 8-Lead Plastic Mini-DIP (N), Cerdip (Q) and SOIC (R) Packages –IN R G –V S +IN R G +V S OUTPUT REF 1 2 3 4 8 7 6 5 AD620 TOP VIEW REV.
AD620–SPECIFICA TIONS (Typical @ +25 8 C, V S = 6 15 V, and R L = 2 k V , unless otherwise noted) AD620A AD620B AD620S 1 Model Conditions Min Typ Max Min Typ Max Min Typ Max Units GAIN G = 1 + (49.4 k/R G ) Gain Range 1 10,000 1 10,000 1 10,000 Gain Error 2 V OUT = ± 10 V G = 1 0.
AD620 AD620A AD620B AD620S 1 Model Conditions Min Typ Max Min Typ Max Min Typ Max Units DYNAMIC RESPONSE Small Signal –3 dB Bandwidth G = 1 1000 1000 1000 kHz G = 10 800 800 800 kHz G = 100 120 120 120 kHz G = 1000 12 12 12 kHz Slew Rate 0.75 1.2 0.
AD620 REV. E –4– NOTES 1 Stresses above those listed under Absolute Maximum Ratings may cause perma- nent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied.
AD620 REV. E –5– T ypical Characteristics (@ +25 8 C, V S = 6 15 V, R L = 2 k V , unless otherwise noted) INPUT OFFSET VOLTAGE – m V 20 30 40 50 –40 0 +40 +80 PERCENTAGE OF UNITS –80 SAMPLE SIZE = 360 10 0 Figure 3.
AD620–T ypical Characteristics FREQUENCY – Hz 1000 100 10 1 10 1000 100 CURRENT NOISE – fA/ ! Hz Figure 9. Current Noise Spectral Density vs. Frequency RTI NOISE – 2.0 m V/DIV TIME – 1 SEC/DIV Figure 10a. 0.1 Hz to 10 Hz RTI Voltage Noise (G = 1) RTI NOISE – 0.
AD620 REV. E –7– FREQUENCY – Hz PSR – dB 160 1M 80 40 1 60 0.1 140 100 120 100k 10k 1k 100 10 20 G = 1000 G = 100 G = 10 G = 1 180 Figure 14. Positive PSR vs. Frequency, RTI (G = 1–1000) FREQUENCY – Hz PSR – dB 160 1M 80 40 1 60 0.1 140 100 120 100k 10k 1k 100 10 20 180 G = 10 G = 100 G = 1 G = 1000 Figure 15.
AD620 REV. E –8– OUTPUT VOLTAGE SWING – Volts p-p LOAD RESISTANCE – V 30 0 0 10k 20 10 100 1k V S = 6 15V G = 10 Figure 20. Output Voltage Swing vs. Load Resistance .... .... .... .... .... .... .... .... .... .... .... .... .... .... .... ...
AD620 REV. E –9– .... .... .... .... .... .... .... .... ........ .... .... .... .... .... .... .... .... ........ Figure 26. Small Signal Pulse Response, G = 100, R L = 2 k Ω , C L = 100 pF .... .... .... .... .... .... .... .... .... .... ....
AD620 REV. E –10– V B –V S A1 A2 A3 C2 R G R1 R2 GAIN SENSE GAIN SENSE R3 400 V 10k V 10k V I2 I1 10k V REF 10k V +IN – IN 20 m A 20 m A R4 400 V OUTPUT C1 Q2 Q1 Figure 33. Simplified Schematic of AD620 THEORY OF OPERATION The AD620 is a monolithic instrumentation amplifier based on a modification of the classic three op amp approach.
AD620 REV. E –11– Make vs. Buy: A Typical Bridge Application Error Budget The AD620 offers improved performance over “homebrew” three op amp IA designs, along with smaller size, fewer compo- nents and 10 × lower supply current.
AD620 REV. E –12– 3k V +5V DIGITAL DATA OUTPUT ADC REF IN AGND 20k V 10k V 20k V AD620B G=100 1.7mA 0.10mA 0.6mA MAX 499 V 3k V 3k V 3k V 2 1 8 3 7 6 5 4 1.
AD620 REV. E –13– Precision V-I Converter Th e AD620, along with an other op amp and tw o resistors, makes a precision current source (Figure 37). The op amp buffers the reference terminal to maintain good CMR. The output voltage V X of the AD620 appears across R1, which converts it to a curre nt.
AD620 REV. E –14– COMMON-MODE REJECTION Instrumentation amplifiers like the AD620 offer high CMR, which is a measure of the change in output voltage when both inputs are changed by equal amounts. These specifications are usually given for a full-range input voltage change and a speci- fied source imbalance.
AD620 REV. E –15– GROUND RETURNS FOR INPUT BIAS CURRENTS Input bias currents are those currents necessary to bias the input transistors of an amplifier.
AD620 REV. E –16– OUTLINE DIMENSIONS Dimensions shown in inches and (mm). Plastic DIP (N-8) Package 8 14 5 0.430 (10.92) 0.348 (8.84) 0.280 (7.11) 0.240 (6.10) PIN 1 SEATING PLANE 0.022 (0.558) 0.014 (0.356) 0.060 (1.52) 0.015 (0.38) 0.210 (5.33) MAX 0.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Analog Devices AD620 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Analog Devices AD620 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Analog Devices AD620 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Analog Devices AD620 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Analog Devices AD620, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Analog Devices AD620.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Analog Devices AD620. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Analog Devices AD620 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.