Manuale d’uso / di manutenzione del prodotto RM-P210 del fabbricante JVC
Vai alla pagina of 32
INSTRUCTIONS REMOTE CONTROL UNIT RM-P210 RM-P210 REMOTE CONTROL UNIT SC961002-003-H R d For Customer Use: Enter below the Model No. and Serial No. which are located on the bodie. Retain this information for future reference. Model No. RM-P210 Serial No.
2 1. Read all of these instructions. 2. Save these instructions for later use. 3. All warnings on the product and in the operating instructions should be adhered to. 4. Unplug this appliance system from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners.
3 INTRODUCTION INTRODUCTION Features ........................................................................... 4 Provided Accessories and Documents ............................ 4 Precautions for Proper Use ...........................................
4 Do not supply pow er to the RTS terminals at the rear . These terminals are not designed to accept a power supply . To prolong the ser vice life of the RM-P210 , do not use it or store it in the following places. A place subject to e xtremely high or low temperatures.
5 1 Intercom jac k Connect the intercom headset to this jack. REF. : “Intercom” on page 14. 2 [INTERCOM LEVEL] control Use this knob to adjust the intercom ear phone v olume. 3 [T ALL Y] lamp This lamp lights when a signal is input to the T ALL Y termi- nals 2 on the rear panel.
6 INTRODUCTION CONTROLS, CONNECT ORS AND INDICA T ORS (CONTINUED) ! [PO WER] switc h Press this switch to turn the pow er ON and OFF . @ [WHITE - W .BAL B/A/PRESET] s witch This switch s witches the white balance control setting be- tween the v alue stored in Memor y B (A UT O 2), that stored in Memor y A (A UTO 1) and the PRESET v alue (3200K).
7 1 [A C ` IN] connector Connect this sock et to a commercial power supply outlet using the power cord pro vided. 2 [T ALL Y] terminals These ter minals input the tally signals . ● When the contact between the PGM (Progr am) and C (Common) terminals is closed, the T ALL Y lamp 3 on the front panel lights in RED .
8 CONNECTION EXAMPLE OF BASIC CONNECTION Standard connection of the RM-P210 (Connection of a single unit) HG C C PVW PGM TALLY INTERCOM AUX VIDEO INPUT GENLOCK INPUT VIDEO OUTPUT Y/C OUT CAMERA CA.
9 CONNECTION EXAMPLE OF RM-P210 (CONNECTION OF 2 UNITS) Standard connection of RM-P210 (Connection of 2 units) Monitor Intercom headset KA-320 Camera cab le VC-P110 Camera cab le VC-P110 Intercom headset KA-310 Monitor To power supply Intercom T ally Return video YC BB OUT YC Special effects generator , etc.
10 CONNECTION CAMERA SETUP Before turning the RM-P210 on, be sure to set up the camera as shown below . GY-D V550 camera KY-D29/KY-D29W camera SHUTTER STATUS MENU FILTER 3200k 1 5600k+1/8ND 2 5600k+1/64ND 3 ALARM MONITOR OPERATE NG GAIN OUTPUT WHT.
11 PAINT AUTO B R W.BAL AUTO MANU WHITE MASTER BLACK POWER I O IRIS P B A PRESET CLOSE OPEN MID REMOTE CONTROL UNIT RM-P210 POWER s witch 1. Connect the camera to the RM-P210 using a proper con- nection method. 2. Set the camera s witches as shown on the pre vious page.
12 1. Press and hold the MENU b utton f or about 1 second until the LCD display sho ws the menu display . T ur n the con- trol knob to mov e the cursor ( ) to "2: CABLE".
13 ADJUSTMENTS FOR GENLOCK OPERA TION Genlocking is required f or a system, which uses an SEG (special effects generator) as the main signal source. REF. : “Example of RM-P210 (Connection 2 units) ” on pag e 9. PREP ARA TIONS AND MAIN FUNCTIONS Preparation 1.
14 The intercom emplo ys the RTS system. If it is required to change this to a 2-wire system, consult y our nearest JVC-authorized service agent. (The modification will then be carried out with charge.) An intercom jac k is provided on the front panel of the RM-P210.
15 FUNCTION KEYS Up to four of the functions listed at the bottom of this pa ge can be assigned to function keys F1 to F4 so that each function can be switc hed on or off by pressing the corresponding ke y . (For the assignment of functions: REF. Items 5H to 5K, “FUNC1” to “FUNC4” in the OPERA TION MENU description on page 25.
16 1. Press the SHUTTER control to activ ate the shutter speed var iation facility , which is indicated by the lighting of the SHUTTER lamp . 2. Tu rn the SHUTTER control to vary the shutter speed. The LCD display sho ws the shutter speed during the adjust- ment operation.
17 IRIS ADJUSTMENT The camera lens iris can be adjusted from the RM-P210. CAMERA ADJUSTMENTS 1. When the lamp in the IRIS AU T O/MANU b utton is not lit, the iris control is set to AU TO mode , in which the ir is le vel is controlled automatically according to the light intensity .
18 WHITE BALANCE ADJUSTMENT Since color temperature varies depending on the light sour ce, the white balance should be ad- justed whenever the main light sour ce illuminating the object being shot changes. CAMERA ADJUSTMENTS AU TO white balance adjustment (A UTO SETUP) 1.
19 FLO W OF MENUS MENU OPERA TION 1: GENLOCK 1A: H PHASE 1B: SC COARSE 1C: SC FINE 0 to 255 0 ° , 90 ° , 180 ° , 270 ° 0 to 255 1Z: BACK 2: CABLE 2A: LENGTH 2B: Y CABLE EQ 2C: C CABLE EQ 5M, 20M, .
20 MENU SETUP METHOD Each men u is displayed on the LCD displa y and can be set up using the MENU button and the contr ol knob. The v alues set in the "4: PROCESS" and "5: OPERA TION" menus can be sa ved in files A and B. MENU OPERA TION 1.
21 GENLOCK MENU MENU OPERA TION This menu is used to set the camera cable length to the length actuall y used. ( REF. : “Adjustments for Genloc k Operation” on page 13.
22 FILE MENU The v alues set with the menu and applied to the RM-P210 can be saved in tw o files named A and B. MENU OPERA TION 1. Press and hold the MENU b utton for 3 seconds until the LCD display sho ws the menu display . The cursor ( ) in- dicates that the item being pointed to can be varied.
23 PROCESS MENU MENU OPERA TION ON NORMAL NORMAL MIDDLE OFF ON NORMAL ON No. Item Function, Operation Av ailable Settings Initial Setting 4A 4B 4C 4D 4E 4F 4G 4H DET AIL DET AIL LEVEL DET AIL V/H DET AIL FRQ SKIN DET AIL AU TO KNEE KNEE POINT COLOR MA TRIX ON/OFF setting of the detail enhancement function.
24 PROCESS MENU (CONTINUED) MENU OPERA TION NORMAL OFF NORMAL NORMAL 4:3 OFF MIDDLE — No. Item Function, Operation Av ailable Settings Initial Setting 4I 4J 4K 4L 4M 4N 4O 4Z V .RESOLUTION GAMMA GAMMA LEVEL BLA CK ASPECT RA TIO DNR DNR LEVEL BACK Increases the v er tical resolution.
25 OPERA TION MENU MENU OPERA TION This menu sets the functions b uilt into the RM-P210. STEP 0.1 dB 18.0 dB 0 dB 9 dB 18 dB OFF BLA CK STRETCH BLA CK COMPRESS ALC+EEI LOLUX – No. Item Function, Operation Av ailable Settings Initial Setting 5A 5B 5C 5D 5E 5F 5G 5H 5I 5J 5K 5Z SHUTTER V.
26 LCD MODE MENU This menu sets up the LCD displa y . NORMAL ON – No. Item Function, Operation Av ailable Settings Initial Setting 6A 6B 6Z CONTRAST BA CKLIGHT BACK Adjusts the contrast of the LCD displa y . Adjusts the setting of the backlight of the LCD displa y .
27 MENU OPERA TION SYSTEM RESET MENU This menu resets the values set b y the user to the initial v alues. 1. Press and hold the MENU button (appro x. 1 second) until the LCD displa y shows the menu displa y . Then turn the con- trol knob to mov e the cursor ( ) to "7: SYSTEM RESET".
28 WARNING MESSA GES To prevent operational err ors, the LCD display shows one of the f ollowing warning messa ges when an err oneous operation is performed. Display ed Message INV ALID ENTR Y GAIN : LOLUX INV ALID ENTR Y FULL A UT O : ON INV ALID ENTR Y GAIN : ALC + EEI INV ALID ENTR Y W .
29 FUNCTIONS AV AILABLE DEPENDING ON CAMERA MODELS GENERAL Function Connected Model GY- D V550 KY- D29 KY- D29W KY-27C KY-19 : Av ailable. : Not availab le. : Connectable b y modifying the KY -D29W . Consult your nearest JVC-authorized service agent for details.
30 TROUBLESHOO TING GENERAL Colors in the monitor screen are abnormal. (During genlocking) • Is the SC phase adjusted properly? P. 13 Synchr onization is not possible. • Are the BB or VBS signals applied to the GENLOCK INPUT connectors? • Is the VCR pla yback signal supplied directly without passing through a TBC? P.
31 SPECIFICA TIONS GENERAL Output Signals Composite video signal :1 V(p-p), 75 W , 2 output R/G/B signals : 0.7 V(p-p), 75 W , x 1 each (with- out sync) Y/R-Y/B-Y signals :Y : 1 V(p-p), 75 W (including sync) R-Y : 0.7 V(p-p), 75 W , B-Y : 0.7 V(p-p), 75 W , (75% color bar) Y/C signal :Y : 1 V(p-p), 75 W (including sync) C: 0.
is a registered trademark owned by Victor Company of Japan, Limited. is a registered trademark in Japan, the U.S.A., the U.K. and many other countries.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il JVC RM-P210 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del JVC RM-P210 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso JVC RM-P210 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul JVC RM-P210 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il JVC RM-P210, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del JVC RM-P210.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il JVC RM-P210. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo JVC RM-P210 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.