Manuale d’uso / di manutenzione del prodotto CV-M91 del fabbricante JAI
Vai alla pagina of 28
3 CCD RGB Color Camera CV -M91 Operation Manual Camera: Revision A Manual: Version 1.1 M91Manualjan19.doc JPT 19 -01-04.
CV-M91 - 1 - Table of Contents 1. General ............................................................................................... 2 2. Standard Co mposit ion ............................................................................. 2 3. Main Fe atures .
CV-M91 1. Gener al The CV-M91 3 CCD RGB color camera is a new upda ted versi on of CV-M90. The prism is i mproved, and new CCD sensors are used. The new CCD sensor has 5 dB higher sen sitivity, 15 dB lower smear and 4 dB higher dynamic range. Now ther e are Y/C output and input for composite sync.
CV-M91 4. Locations and F unctions 11 1. Prism 2. Lens mount (C-mount). Thread max 4 mm 3. Switch SW1 for mode settings 4. 6 pin Trigger input and RS-232C c onnector 5. 12 pin DC in/Sync connector 6. 9 pin Sub-D connector for video 7. Red gain potentiometer 8.
CV-M91 - 4 - 5. Pin Assignment 5.1. 12-pin Multi-conne ctor (DC-IN/Trigger) Type: HR10A-10R-12PB-01(Hirose) male. Plugs for cable: HR10A-10P-12S (Seen from rear of came ra.
CV-M91 - 5 - 5.3. 9-pin Sub D-connector (Video) Type: male. N Pin no. Signal Remarks 1 GND 2 GND 3 R output 75 Ω source. 4 G out or G+S output 75 Ω source. *) , SW604-4 off for G out 5 B output 75 Ω source 6 Y video out or VBS out 75 Ω source.
CV-M91 - 6 - HD, VD, WEN, EEN and PCLK o utput GND 10 10 10k 10k 67 TTL 220 GND 10 10 10k 10k 67 TTL 220 The output circuit for HD, VD, WEN, EEN and PCLK are complementary emitter followers with 75 Ω in series. Output level is 4V. (Non-terminated). Fig.
CV-M91 - 7 - 6. F unctions and Oper ations The different camera modes and functions can be set by switches and jumpers. Some functions like RGB setup and white clip can only be changed via RS-232C. Function names within “ “ are names used in camera control tool.
CV-M91 - 8 - 6.1.2. Internal sync out/WEN out On pin #7 on 9 pin sub-D connector, the factory setti ng is the internal composite sync signal o ut. By jumper settings it can be changed to WEN out. Refer to “7. Configuring the Camera.” To use this mode: Set function on PK8407: JP303 o, JP304 s for sync output.
CV-M91 - 9 - 6.2. Trigger Modes This camera can operate in 5 prima ry modes. 1 non-triggered, 3 externa l H synchronous trigger modes and 1 long time integration mode. 1. Normal continuous Mode . Pre-selected exposure. 2. Edge Pre-select Mode. Pre-selected exposure.
CV-M91 - 10 - 6.2.1. Continuous Operation (Non triggered) Trigger Mode Normal. It is for applications whe re the camera is continuous running without external trigger. The shutter will work in all 8 steps up to 1 /10,000 second. Refer to “7. Configuring the Came ra.
CV-M91 - 11 - Fig. 15. Vertical timing PAL interlaced Fig. 16. Vertical timing PAL non-int erlaced. Field accumulation.
CV-M91 - 12 - Fig. 17. Vertical timing NTSC interlaced Fig. 18. Vertical timing NTSC non - interlaced. Field accumulation.
CV-M91 - 13 - 6.2.2. Edge Pr e-select Mode The exposure will start at the first HD after th e trigger leading edge, and it stops after the selected shutter time, and the resulting video is read out. An EEN pulse indicate the accumulation time, and a WEN pulse that the resulting video read out.
CV-M91 - 14 - 6.2.3. Pulse Width Co ntrol Mode The exposure will start at the first HD after th e trigger leading edge, and it stops between the first and second HD after the trigger trailing edge. An EEN pulse indicate the accumulation time, and a WEN pulse indicates that the resulting video is read out.
CV-M91 - 15 - 6.2.4. Start Stop Mode The exposure time is controlled by the interval between the ext. trigger and the ext. VD signal. The exposure starts at the first HD pulse after t he falling edge of the ext. trigger, and stops 14.5 H after the falling edge of the VD pulse.
CV-M91 - 16 - 6.2.5. Long time integration The exposure time is the interval between 2 ext. VD pulses sent to the VD input. (Pin No. 7 of the 12-pin connector). The exposure starts after in put of the first ext. VD pulse, and ends after the next input of the next ext.
CV-M91 - 17 - 6.3. Other Functions. Refer to “7. Configuring the Camera .” Scanning: SW1-5 on rear selects interlaced or non-interlaced. Non -interlaced PAL = 312H in EVEN field. Non-interlaced NTSC = 262 H in ODD field. Gamma: SW1-6 on rear for gamma select.
CV-M91 - 18 - 7. Configuring the Camer a 7.1 Switch settings The switch positions are shown in factory setting. Names in bold italic is factory setting.
CV-M91 - 19 - 7.2. Jumper settings inside Factory settings is shown in bold italic HD/VD input output on pin #6 and # 7 on 12 pin connector. Jumper HD/VD in HD/VD out Remarks JP305 short open JP306 open short VD input/output. JP308 short open JP309 open short HD input/output.
CV-M91 - 20 - 7.3. Switch and jumper positions Fig. 35. Board positions. 2 3 4 1 Front Rear 1. PK8407 2. PK8404 3. PK8406 4. PK8408 JP 312 JP 301 JP 313 JP 304 JP 303 JP 308 JP 306 SW 301 JP310 JP311 JP315 JP318 JP319 JP302 JP309 JP305 SW 301 fo r 75 Ω term.
CV-M91 - 21 - 7.3. RS-232C control The CV-M91 camera functions can be set up via the RS-232C port on the 6 pin HR connector. The JAI camera control tool for CV-M9 1 can be used for it. To use this mode: Set function: Control. SW1-8 on rear to ON. RS-232C.
CV-M91 - 22 - 7.5. Camera Control Tool for CV-M91 From www.jai.com Camera Control Tool for Windows 98/NT/2000 can be downloaded. The control tool contains a camera control program and tools for maki ng your own program. For the integrator and experienced user, the Camera Control Tool is m uch more than a program with a window interface.
CV-M91 - 23 - 8. External Appear ance and Dimensions Important notes. • C-mount thread on lens should be less than 4.0 mm. • Use only lenses designed for 1/3” 3 CCD cameras. Fig. 41. Outline. 9. Specifications 9.1. Spectral sensitivity The resulting relative response for t he prism and the CCD sensor cha racteristics combined.
CV-M91 - 24 - 9.2. Specification table Specifications CV-M91P CV-M91N Scanning system CCIR PAL, 25 frames/sec. 625 lines, 2:1 Interlaced EIA NTSC. 30 frames/sec. 525 lines, 2:1 Interlaced Frame rate 50 Hz 59.94 Hz Line frequency 15.625 kHz 15.734 kHz Pixel frequency 14.
CV-M91 - 25 - 9.3. CV-M91 Opto-mechanical specifications Fig. 43. Opto mechanical specifications..
CV-M91 - 26 - 10. Appendix 10.1. Precautions Personnel not trained in dealing with similar elec tronic devices should not service this camera. The camera contains components sensitive to el ectrostatic discharge. The handling of these devices should follow the requirements of electrostatic se nsitive components.
CV-M91 - 27 - 11. Users Record Camera type: CV-M91 Revision: (Revision A) Serial No. …………….. For camera revision hi story, please contact your local JAI distributor.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il JAI CV-M91 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del JAI CV-M91 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso JAI CV-M91 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul JAI CV-M91 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il JAI CV-M91, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del JAI CV-M91.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il JAI CV-M91. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo JAI CV-M91 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.