Manuale d’uso / di manutenzione del prodotto K272000AF 7/06 del fabbricante Jacuzzi
Vai alla pagina of 64
BUILDER/C OMFORT BA TH SERIES ELECTRONIC & MANUAL CONTROLS INST ALLA TION AND OPERA TING INSTRUCTI ONS Inst aller: Leave this manual for homeowner . Homeowner: Read this manual and keep for future reference. © 2005 Jacuzzi Whirlp ool Bath K272000AF 7/06 Owner's Record Save These Instruct ions for Future Us e.
ENGLISH IMPORT ANT SAFET Y INSTR UCTIO NS READ AND FOLLOW ALL INSTRUCTIONS SA VE THESE INSTRUCTIO NS IN ST RU CT IO N S PER T AIN I NG T O A RI SK OF FI RE , EL EC TR IC SH OC K, O R I NJ UR Y T O PER.
ENGLISH NOTE: This is a professional grade product. A knowledge of construction techniques, plumbing and electri- cal inst allation according to codes are required for proper installat ion and user satisfaction. W e recommend that a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath product s.
ENGLISH CONTENTS Safety Instructions _________________ ________________________________ ____________________ 2-3 Contents ______________ ______________________ ______________________ _________________.
ENGLISH Important: Read complete instructions before beginning installation. Each whirlpool bath arrives ready for installation, completely equipped with motor/pump assembly and plumbing and fittings necessary for whirlpool operation. An optional drain/overflow kit is available for installation on the bath.
ENGLISH 6 Jacuzzi Whirlpool Bath K272000AF 7/06 SPECIFICATIONS (Rectangular) LH = Left Hand, RH = Right Hand MODE L PROD UCT WEIGHT OPERAT ING GALL ONA GE TOTAL WEIGHT/ FLOOR LOA DING DIMENSI ONS DRA .
ENGLISH SPECIFICATIONS (Rectangular) LH = Left Hand, RH = Right Hand MODE L PROD UCT WEIGHT OPERAT ING GALL ONA GE TOTAL WEIGHT/ FLOOR LOA DING DIMENSI ONS DRAI N/OV ERFL OW DIMENSI ONS SKIRT & MOUNTIN G CUTOUT HEATER READ Y FOR FIELD INSTALLAT ION *Add 1/4" (6,4 mm) to this dimension when roughing-in for 3-wall niche.
ENGLISH RIMLESS OVAL BATHS SIDE VIEW END VIEW L H 7-1/2" (191 mm) W 2" (51 mm) FRESCO 3-1/2" (89 mm) 8" (203 mm) L W H 2'' (51 mm) MILANO SIDE VIEW END VIEW RIV A 5 &.
ENGLISH MODE L PROD UCT WEIGHT OPERAT ING GALL ONA GE TOTAL WEIGHT/ FL O O R LO AD I N G SPECIFICATIONS (Corner) LH = Left Hand, RH = Right Hand DIMENSI ONS DRAI N/OV ERFL OW DIMENSI ONS SKIRT & M.
ENGLISH ROUGHING-IN REFERENCE (RECT ANGULAR) AMIGA ™, Left Hand *72'' 18'' 36'' 2'' 16'' x 4'' 14'' 12" H x 18" L Service Access 11-1/8'' Motor Opt.
ENGLISH MITO™ 5, Left Hand 30" 42" *60" 10" x 4" 2" 11-7/8 " Motor 12" H x 18" L Service Access Opt. Service Access 5-3/8" MITO™ 5, Right Hand 30" 42" *60" 10" x 4" 2" 11-7/8" Motor 12" H x 18" L Service Acces s O pt.
ENGLISH ROUGHING-IN REFERENCE (RECT ANGULAR) 12 Jacuzzi Whirlpool Bath K272000AF 7/06 36" 42" *72" 11-7/8" MITO™ 6, Right Hand 10" x 4" 2" Motor 12" H x 18" L Service Access Opt.
ENGLISH ROUGHING-IN REFERENCE (RECT ANGULAR) 13 Jacuzzi Whirlpool Bath K272000AF 7/06 SIGNA™ 5, Left Hand *60" 12" 42" 5" 4-1/4" 13" x 5" 30" Motor 12" H x 18" L Service Access Opt.
ENGLISH ROUGHING-IN REF ERENCE (OV AL) NOTE: These units have been provided with cutout templates included in shipping carton. See CUTOUT information for each model on page 8.
ENGLISH ROUGHING-IN REF ERENCE (OV AL) NOTE: These units have been provided with cutout templates included in shipping carton. See CUTOUT information for each model on page 8.
ENGLISH ROUGHING-IN REFERENCE (CORNER) 16 Jacuzzi Whirlpool Bath K272000AF 7/06 27" 27" 60" 43-1/8" 6" 60" 34-15/16" 14" X 4" 33-1/2" 46-5/8" CAPELLA 60 w/FRONT LEFT MOTOR/PUMP, Left Hand Ref.
ENGLISH Motor Overflow 25-1/2" (648 mm) 58" (1473 mm) 45-9/16" (1 157 mm) 58" (1473 mm) 25-1/2" (648 mm) TARA CORNER CUTOUT Right Hand Drain 59" Ref.
ENGLISH Framing and Support The drain/overflow of the bath extends below the bottom of the bath. Note that this requires a cutout in the floor. The floor structure beneath the bath must be able to support a tot al weight of bath, water , and bather . Refer to the t able under tot al weight for your model.
ENGLISH INTEGRAL SKIRT MOUNTING DET AIL FINISHING MA TERIALS SKIRT P ANEL CAULKING BEAD U FRAME SKIRT MOUNTING DET AIL SECURE BOTT OM OF FRAME T O FLOOR FINISHING MA TERIALS FILLER (Optional) CAULKING.
ENGLISH MOTOR SERVICE ACCESS (WITH INTEGRAL SKIRT) REMOV ABLE SKIRT ACCESS P ANELS ACCESS AREA 20" 36" 24" 18" B A C SERVICE ACCESS (CORNER BA THS) A - Preferred access B - Accepta.
ENGLISH ELECTRICAL CONNECTION (FOR CORNER BA THS) 3 PRONG PLUG FROM DUPLEX GFCI RECEPT .* *(NOT PROVIDED) FLOOR 4" (10,6 cm) MIN. OR IN ACCORDANCE WITH LOCAL BUILDING OR ELECTRICAL CODES MOTOR PO.
ENGLISH Drain Information A dra in/overflow ass embly (sold separ ately) must be installed on the bath, water tested, and co nnected to the sani tary system of the house. After opening the carton, inspect for damage and verify that the kit is of the proper finish.
ENGLISH UNDER MOUNT INS T ALLA TIO N IN STRUC TIONS Installatio n A typical installation will have these construction character- istics. COUNTER ALL FOAM FEET MUST BE IN CONTACT WITH LEVEL FLOOR Unit Protection If protective film has been removed, reapply film.
ENGLISH UNDER MOUNT INS T ALLA TIO N IN STRUC TIONS Position the counter on top of the bath to ensure correct fit and appearance. Make any adjustments that may be necessary. Remove the counter. BATH COUNTER Adhering Counter to Bath Clean any dirt or debris from the bath rim.
ENGLISH Operation NOTE: These instructions pertain to all Builder/Comfort bath products manufactured by Jacuzzi Whirlpool Bath. Not all features discussed in this instruction booklet apply to all baths.
ENGLISH Controlling Whirlpool Action The whirlpool action in your bath is influenced by three factors – direction of flow , f orce o f wat er , a nd for ce of air . Eve ry bat h man ufac- tured by Jacuzzi Whirlpool Bath that is equipped with fully adjustable PowerPro ® jets, are manually adjust able for direction and water force.
ENGLISH NOTCH GASKET COVER STRAINER SCREW SUCTION FITTING SUCTION COVER/STRAINER ASSEMBL Y Cleaning the Bath T o clean your bath, simply use a mild, nonabrasive liquid deter- gent solu tion. Y ou ca n p rotect an d r estore th e g loss to a d ulled acrylic surface by applying an acrylic polish or automotive paste wax.
ENGLISH 28 Jacuzzi Whirlpool Bath K272000AF 7/06 Gen er al W hir lp oo l Ba th T ro ub les ho ot ing G ui de PROBABLE CAUSES PROBLEM REMEDY NOTE: If unit is within the warranty period, contact Jacuzzi Whirlpool Bath Service Support at 1- (800)- 288-4002 with bath's serial number before work is started.
ENGLISH © 2005 Jacuzzi Wh irlpool Bath K27 2000AF 7/06 Printed in the U.S.A. Printed on Recycled Paper Jacuzzi Luxury Bath 14525 Monte Vista Ave., CA 91710 Service Support: 1-(800) 288-40 02 PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
ENGLISH AUTHORI ZED SER VICE If you need a referral for a service company near you, or need assistance with operation or maintenance related que st io ns , ple as e cal l our Ser vic e Su ppo rt Dep ar tm en t at 1-8 00 -2 88 -4 00 2. Vis it our we b sit e at htt p: // ww w .
WARRANTY COVERAGE Jacuzzi Whirlpool Bath (the “Company”) offers the following expr ess limited warranty to the origin al purchaser of any Jacuzzi Whirlpool Bath B uilder/ Comfort Group Bath Product (“unit”) who purchases the product for personal or single family use (“user”).
RESPONSIBILITIES OF OTHERS Inspecting the u nit prior to installation is the responsibility of the in staller or buildi ng contractor wh o acts on behalf of the user.
ESP AÑOL SERIE DE TINAS BUILDER/COM FORT CONTRO LES ELECTRÓNIC OS Y MANUALES MANUAL DE INST ALACI ÓN Y OPERAC IÓN Inst alador: Deje este manual para el propietario. Propiet ario: Lea este manual y guardelo para referencia en el futuro. Registro d el Propiet ario Conserve Est as Instrucci ones Par a Uso F uturo.
ESP AÑOL INSTRUC CIONES IMPORT ANTES SEQURI DAD LÉA Y SIQUE TODAS LAS INSTRUCCIONES GUARDE EST AS INSTRUCCI ONES INSTRUCCI ONES q ue PERT ENECEN A UN RIESGO DE el FUEGO , DE el CALAMBR E, O DE la HE.
ESP AÑOL LAS ESPECIFICACIONES DE LOS PRODUCTOS ESTÁN SUJET AS A CAMBIOS SIN A VISO. UTILICE LAS INSTRUCCIONES DE INST ALACIÓN ENTREGADAS CON EL PRODUCTO. La empresa ha obtenido los listados de los códigos aplicables (normas) que suelen estar disponibles a nivel nacional para produ ctos de este ti po.
ESP AÑOL T ABLA DE CONTE NIDO Instrucciones de seguridad ______________________________________________________________ 2-3 T abla de contenido ____________________ _____________________________ ____.
ESP AÑOL Import ante: Lea las instrucciones antes de iniciar la instalación. Las tinas de hidromasaje se entregan listas para instalarse y completamente equipadas con motor , bomba, accesorios de plomería y mecanismos necesarios para el hidromasaje.
ESP AÑOL *Añada 1/4" (6,4 mm) a esta medida al instalar las unidades de 3 muros. 60" (1524 mm) L * 30" ( 762 mm) W 20-1 /4" ( 483 mm) H 662 lb (301 kg)/ 53 lb/pies 2 (259 k g/m 2 ) 38 U.
ESP AÑOL 15-7 /8" (403 mm) A 9-1/4" (235 m m) B NOV A © 5 CON FA LDÓN INTEG RADO LH & RH 60" (1524 mm) L * 42" (1067 mm) W 18-1 /2" ( 470 mm) H 737 lb (335 kg)/ 42 lb/pies 2 (205 k g/m 2 ) 45 U.
ESP AÑOL VIST A DE FRENTE H W VIST A LA TERAL L 2" (51 mm) LUNA TINAS OVALADAS SIN BORDES VIST A LA TERAL VIST A DE FRENTE L H 7-1/2" (191 mm) W 2" (51 mm) FRESCO 3-1/2" (89 mm) 8.
ESP AÑOL H 2" (51 mm) VIST A LA TERAL VIST A DE FRENTE TINAS DE ESQUINA DESAGÜE/REBOSADERO A B TINAS DE ESQUINA 60" (1524 mm) L 60" (1524 mm) L 20-3 /4" ( 527 mm) H 984 lb (447 k/g)/ 39 lb/pies 2 (190 k g/m 2 ) 74 U.
ESP AÑOL DIAGRAMAS EN PLANT A DE INST ALACIONES (RECT ANGULAR) 10 Jacuzzi Whirlpool Bath K272000AF 7/06 *Añada 1/4 pulgadas (6,4 mm) a esta medida al instalar las unidades de 3 muros. NOT A : 1. Las dimensiones en general son nominales con una tolerancia de +0 y -1/4 pulgadas (6,4 mm).
ESP AÑOL DIAGRAMAS EN PLANT A DE INST ALACIONES (RECT ANGULAR) 1 1 Jacuzzi Whirlpool Bath K272000AF 7/06 *Añada 1/4 pulgadas (6,4 mm) a esta medida al instalar las unidades de 3 muros. NOT A : 1. Las dimensiones en general son nominales con una tolerancia de +0 y -1/4 pulgadas (6,4 mm).
ESP AÑOL DIAGRAMAS EN PLANT A DE INST ALACIONES (RECT ANGULAR) 12 Jacuzzi Whirlpool Bath K272000AF 7/06 *Añada 1/4 pulgadas (6,4 mm) a esta medida al instalar las unidades de 3 muros. NOT A : 1. Las dimensiones en general son nominales con una tolerancia de +0 y -1/4 pulgadas (6,4 mm).
ESP AÑOL DIAGRAMAS EN PLANT A DE INST ALACIONES (RECT ANGULAR) *Añada 1/4 pulgadas (6,4 mm) a esta medida al instalar las unidades de 3 muros. NOT A : 1. Las dimensiones en general son nominales con una tolerancia de +0 y -1/4 pulgadas (6,4 mm). 2. Mantenga las dimensiones del acceso dadas son tamaño mínimo.
ESP AÑOL DIAGRAMAS EN PLANT A DE INST ALACIONES (OV ALADAS) NOT A : Estas unidades se han proporcionado con plantillas de recorte incluidas en el envío el cartón.
ESP AÑOL DIAGRAMAS EN PLANT A DE INST ALACIONES (OV ALADAS) NOT A : Estas unidades se han proporcionado con plantillas de recorte incluidas en el envío el cartón.
ESP AÑOL DIAGRAMAS EN PL ANT A DE INST ALACIONES (ESQUINA) 27" 27" 60" 43-1/8" 6" 60" 34-15/16" 14" X 4" 33-1/2" 46-5/8" CAPELLA 60 PARA IZQUIERDA DELANTERA MOTOR/BOMBA, Mano Izquierda Ref.
ESP AÑOL DIAGRAMA EN PLANT A DE TINAS DE ESQUINA Motor 25-1/2" (648 mm) 58" (1473 mm) 45-9/16" (1 157 mm) 58" (1473 mm) 25-1/2" (648 mm) 59" Ref.
ESP AÑOL Estructura y Soporte La instalación del desagüe y el rebosadero se extiende por debajo de la parte inferior de la tina. Cabe señalar que para esto se requiere hacer un corte en el piso. La estructura del piso, debajo de la tina, debe poder soportar el peso total de la tina, el agua, y el ocupante.
ESP AÑOL Tinas de Esquina con Faldón Si se usa faldón en la tina de esquina, es necesario contar con mayor soporte en la p arte frontal de la unidad.
ESP AÑOL Acceso pa ra Servicio En el caso de ins talaci ones parc ial o totalm ente emp otrad as, deje un acceso a las conexiones. Es responsabilidad del instalador dejar espacio suficiente para el registro. Las medidas mínimas re- comendables para el registro de la tina se muestran e n la ilustración que lleva el nombre de “Registros”.
ESP AÑOL Conexione s Eléctri cas Se requiere un circuito independiente protegido con un interruptor de circuito para fallas a tierra (GFCI). Instale un contacto dúplex en el muro debajo de la tina, por lo menos 4 pulgadas arriba del piso.
ESP AÑOL Información Sobre el Drenaje Debe instalarse una unidad de drenaje/rebosadero (se vende separado) en la tina, verificar que no presente fugas y conectarse al sistema sanitario de la casa. Después de abrir la caja de cartón, verifique que no hay daños y revise el acabado.
ESP AÑOL 23 Jacuzzi Whirlpool Bath K272000AF 7/06 INSTRUC CIONES de INST ALACION de U NDERMOU NT Instalación Una instalación típica tendrá estas características de la construcción. MOSTRADOR TODOS PIES de la ESPUMA DEBEN ESTAR EN el CONTACTO CON PISO PLANO Protección de Unidad Si la película protectora se ha quitado, reapliq ue película.
ESP AÑOL 24 Jacuzzi Whirlpool Bath K272000AF 7/06 Posicione el mostrador encima del baño para asegurar el ataque y la apariencia correctos. La marca cualquier ajuste que puede ser necesario. Quite el mostrador. BAÑO MOSTRADOR Que Adhiere Contra al Baño Limpie cualquier tierra o los escombros del borde del baño.
ESP AÑOL OPERAC IÓN NOT A: Estas i nstrucciones se apli can a todos l os produc tos para baño fabricados por J acuzzi Wh irlpool B ath. No todas las características descritas en el folleto de instrucciones se aplican a todas las tinas.
ESP AÑOL Có mo Co nt r ol ar el Sis t em a Hi d ro t er ap e út i co El funcionamiento del sistema hidroterapeútico de la tina lo de- terminan tres factores: dirección del flujo, fuerza del agua y fuerza del aire.
ESP AÑOL MUESCA EMP AQUE FIL TRO TORNILLO A C C E S O R I O D E S U C C I Ó N PLACA PROTECT ORA DE SUCCIÓN/FIL TRO Aditivos de Baño NOT A: NO UTILIZA ADITIVOS DE BAÑO CON BASE ACEITOSA.
ESP AÑOL Guí a Ge ner al d e Re p aro de Fa ll as B año s Hy dro te ra peú ti cos PROBABLES C AUSAS PROBLEMA SOLUCIÓN Bomba/Motor no arranca. Reconecte el GFCI.
ESP AÑOL 29 Jacuzzi Whirlpool Bath K272000AF 7/06 © 2005 Jacuzzi Wh irlpool Bath K27 2000AF 7/06 Printed in the U.S.A. Fibr as reciclables Jacuzzi Luxury Bath 14525 Monte Vista Ave.
ESP AÑOL Si usted necesita obtener información sobre una comp añía de servicios en su cercanía, o necesita asistencia p ara preguntas sobre la operación o mantenimiento del producto, por favor llame a nuestro Depart amento de Servicios de Apoyo, teléfono 1-800-288-4002.
Jacuzzi Luxury Bath 14525 Monte Vista Avenue Chino, CA 91710 Garantía L imit ada de T inas d e "Jacuzzi Whirlpool Bath" Product o de Gr upo de T inas B uilder/ Comfort COBERTURA DE LA GARAN.
RESPONSABILIDAD DE TERCEROS Es responsabilidad del instalador o del contratista constructor que actúen en nombre del usuario realizar una inspección de la unidad antes de instalarla. Ellos son responsables de asegurarse de que la unidad no tiene defectos ni daños.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Jacuzzi K272000AF 7/06 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Jacuzzi K272000AF 7/06 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Jacuzzi K272000AF 7/06 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Jacuzzi K272000AF 7/06 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Jacuzzi K272000AF 7/06, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Jacuzzi K272000AF 7/06.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Jacuzzi K272000AF 7/06. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Jacuzzi K272000AF 7/06 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.