1 GICe702S3R5W6 P ART NO. M0557 Installation Installation Installation Guide RAID 5 eSA T A 3Gbps 2 external port Low pro fi le PCI Express card.
.
3 T able of Contents Caution 4 Introduction 6 Features 7 Package Contents 8 What Is RAID? 9 Installation Procedur e 12 Software Installation 19 V erifying Controller Installation 22 Federal Communicat.
4 Caution • Before installation of the contr oller card we recommend that users study this manual fi rst. This RAID manual has more information on RAID ar chitecture, RAID features, RAID installation, RAID settings and Management software for the RAID5 GUI (Graphical User Interface).
5 • If you’re using a used hard drive with the RAID5 car d you must perform the “Delete RAID Set” under the BIOS settings. The reason this is necessary is because the used har d drive has system data on it which may cause recognition issues when con fi guring it for use with the RAID5 card.
6 Introduction The Low Pro fi le PCI-Express Host Adapter allows support for both Low pro fi le PCI and standard size PCI connections. The card of fers the option of upgrading your desktop with a 2 port Serial A T A II transfer rate of up to 3 Gb/s.
7 Features External SA T A II (eSA T A) Connector . • 48 bits LBA can Break Capacity-Limit to Support HDD larger than 137GB. • Supports 1-lane 2.5Gbps PCI Express. • Hot-plug capability . • Supports SA T A II transfer rate of 3.0Gbps. • Fully compliant with Serial A T A 1.
8 Package Contents RAID5 SA T A II – 3Gbps 2Port PCI Express Host Adapter • Low PCI Bracket • Quick Start Guide • Driver CD •.
9 What Is RAID? RAID - Redundant Array of Independent Disks RAID technology manages multiple disk drives to enhance I/O performance and provide r edundancy in order to withstand the failur e of any individual drive, without loss of data. Disk Striping (RAID 0) Striping is a performance-oriented, non-redundant data mapping technique.
10 Mirror ed-Striping (RAID 0+1 also known as RAID 10) A Mirror ed-Striping Set does just what it says, combining both Striping and Mirroring technologies to provide both the performance enhancements that come fr om Striping and the data availability and integrity that comes from Mirr oring.
11 Just a Bunch of Disks (JBOD/Contiguous) JBOD (also known as Contiguous) means a logical drive that can either be an entire disk drive or a segment of a single disk drive.
12 1. Power down the computer system. 2. Insert the Host card into an available bus slot. 3. Power on the computer system. 4. Install drivers for the device. 5. Remove all existing SA T ARAID GUIs (or Java SA T ARAID GUIs) to ensure your new SA T ARAID5 GUI installs and functions properly .
13 11. Use the SA T ARAID5 Manager GUI to con fi gure your RAID settings. If using 1 Disk, please select “Concatenate” or “Contiguous” settings only . If using 2 Disks, do NOT select “Parity RAID” or “Mirror ed Stripe” settings. If using 3 Disks, do NOT select the “Mirror ed Stripe” setting.
14 BIOS (RAID Settings) Creating and deleting RAID sets is a function found in the BIOS. During boot up, the RAID setting message will appear and pause for a few moments to allow the user access to its settings. The board will act as a normal NON-RAID car d when the BIOS does not have it con fi gured for RAID.
15 5. Select RAID size . Press Enter . 6. Press Y to save your settings. 7. Press CTRL+E and then pr ess Y to exit the setup. 8. Continue with conventional Fdisk and Format steps to prepar e the hard drives. 9. Y our RAID hardware con fi guration is complete.
16 Creating a Mirr ored-Striped Set (RAID 10) 1. As the BIOS boots, press CTRL+S or F4 to enter the RAID bios utility . 2. Select Create RAID set . Pr ess F2 . 3. Select RAID 10 then press Enter . 4. Select Auto con fi guration . Press Enter . 5. Press Y and then pr ess ESC to exit the setup.
17 Creating JBOD Sets 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility . 2. Select Create RAID set . Pr ess Enter . 3. Select JBOD (Single) then press Enter . 4. Select JBOD Drives . Press Enter . 5. Select RAID size . Press Enter .
18 Deleting RAID Sets 1. As the BIOS boots, Press CTRL+S or F4 to enter the RAID bios utility . 2. Select Delete RAID set . Press Enter . 3. Answer Y to remove the RAID set. If the RAID set being deleted is a Striped, then all of the data will be lost.
19 Windows XP Fresh Installation 1. Power off the system. Insert the contr oller card into a PCI slot and connect the hard drives to the controller car d. Power up the system. 2. Put your Windows XP CD into the CD-ROM/DVD drive. 3. Press F6 for thir d party SCSI or driver installation.
20 Windows XP Existing Installation 1. Power off the system. Insert the contr oller card into a PCI slot and connect the har d drives to the controller car d. Power up the system. 2. During OS boot up, Windows will display the ‘Found New Hardwar e Wizard’ .
21 4. Insert the Driver CD in your CD-ROM/ DVD drive, check Specify a location , uncheck the other boxes, click Next , type in your CD-ROM/DVD Drive Letter and Click Browse. 5. Specify the following location: [CD Drive Letter]:SA T A PCIe_Raid5_2Port SiI3132 WindowsDriver .
22 1. Right click on the ‘My Computer’ icon and select ‘Properties’ . Left click on the ‘Hardwar e’ tab then select the ‘Device Manager’ button.
23 Federal Communications Commission (FCC) Statement Federal Communications Commission (FCC) Statement 15.21 Y ou are cautioned that changes or modi fi cations not expressly approved by the part r esponsible for compliance could void the user’ s authority to operate the equipment.
24 - Connect the equipment into an outlet on a circuit dif ferent from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. THIS DEVICE COMPLIES WITH P ART 15 OF THE FCC RULES. OPERA TION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1.
25 CE Statement This device has been tested and found to comply with the requir ements set up in the council directive on the approximation of the law of member states r elating to EMC Directive 89/336/EEC, Low V oltage Directive 73/23/EEC and R&TTE Dir ective 99/5/EC.
26 The manufacturer , IOGEAR, makes NO warranty or repr esentation, whether express or implied, regar ding the contents, use or suitability of this software, disk or documentation.
27 Contact T oll Free: (866) 9-IOGEAR Phone: (949) 453-8782 23 Hubble Irvine, CA 92618 USA www .iogear .com support@iogear .com ©2007 IOGEAR. All Rights Reserved. P ART NO. M0557 IOGEAR, the IOGEAR logo, MiniView , VSE are trademarks or registered trademarks of IOGEAR, Inc.
© 2007 IOGEAR, INC. FUN IOGEAR offers connectivity solutions that ar e innovative, fun, and stylish, helping people enjoy daily life using our high technology products. GREEN IOGEAR is an environmentally conscious company that emphasizes the importance of conserving natural resour ces.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il IOGear GICe702S3R5W6 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del IOGear GICe702S3R5W6 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso IOGear GICe702S3R5W6 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul IOGear GICe702S3R5W6 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il IOGear GICe702S3R5W6, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del IOGear GICe702S3R5W6.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il IOGear GICe702S3R5W6. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo IOGear GICe702S3R5W6 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.