#61 - 846 ND -752 1-1 Page 1 of 25 ® HeatSeeker 160 Du al V iew Thermal Ima ging Camer a Instru ction Manual Saf ety Warn ing: The equ ipment described i n this document uses a Class 2 lase r. Und er no a ccount should anyone look d irectly into the laser beam or the laser beam e xi t apertu re, irreversible damage to the e ye may oc cur.
#61 - 846 ND -752 1-1 Page 2 of 25 Conte nts Page 1. CONTE NTS OF TH E CASE .................................................................................... 3 2. MAI N CONTR OLS .....................................................................
#61 - 846 ND -752 1 -1 Page 3 of 25 1. Co nten ts of th e C ase Carry i ng Case. Camera. USB PS U and I nter n at i o nal Adaptors. CD – 61 -8 4 6 I n s truct i on M anua l and Therm a l V i si o n ™ 16 0 Software and Softwar e I nstruct i on Ma n u al USB Cab l e ( C amera to PC).
#61 - 846 ND -752 1 -1 Page 4 of 25 2. Ma in Con tro ls 2.1 . Back 2.2 . Front 2.3 . Fun cti o n Keys Mi cro phone Speaker Power Button Center Nav igation Key 4 Navi g ation K eys Function K e ys 1 to.
#61 - 846 ND -752 1 -1 Page 5 of 25 3 . G et ting st art ed 3.1 . Swit ching the c a mer a on / off After sw i t ching o n, i t will take up to 30 se c o n ds fo r th e i nfrared i m a ge to appear. T he i mage w i ll per i od i cally fr eeze for o ne or two seconds w hile the camera re -ca l ibr ate s i t self.
#61 - 846 ND -752 1 -1 Page 6 of 25 3.4 Focusing Focu s B ar O ut of Focus Foc us ed When fo cus i ng a f ocus bar appear s on th e scree n to a ss is t i n focu sing the i mag e. I t ind i c ates the app rox i mat e d is ta nce i n feet (i n met ers wh en °C is se l e cted ) of a focused target from the camer a .
#61 - 846 ND -752 1 -1 Page 7 of 25 4. Function butto n s Press i ng any o f t h e F u n c t i o n Ke y butto n s revea ls the ic o ns which ind ic ate th e f u n ctions of these button s.
#61 - 846 ND -752 1 -1 Page 8 of 25 4.2 . Image align ment As the visi b le and th e rma l camera s ar e not co -ax i a l t he visi b le and the rma l i mage m ay need to be a l i g ne d. Th is i s usually r equi r ed when m oving to view obj ec t s a t d i ffe re nt d is ta n ces.
#61 - 846 ND -752 1 -1 Page 9 of 25 4.3 . Tu rning the visible ima ge off and on 4.3.1. Pre ss F unct i on Ke y 2 to togg l e to th e V i s i b l e O n icon . 4.3.2. Pre ss t he c enter n a vi gat i on button to togg le to V i sib l e Off . 4.3.3. Pre ss t he c enter n a vi gat i on button aga i n to togg l e to V isi b le O n .
#61 - 846 ND -752 1 -1 Page 10 of 25 4.5 . Manual contro l The therma l image ga i n and off s e t are norm ally co n tro l led automat ica ll y i n ord e r to g i ve a meaningfu l d isp l a y o n the s c reen. Ho wever, Fu n c t i o n K ey 2 off e rs the op ti on of sw i tc hing to manual c ontr ol i f de si red: 4.
#61 - 846 ND -752 1 -1 Page 11 of 25 5. Menu stru ct ure. Se l e ct the m enu by pres si ng F unct i o n Key 4. Navi g ate throug h the me n u using t he n a vi gat i on button s a n d p re ss F u n ction Key 3 to select th e req ui r e d op t i on . T he h i gh lighted i t e m w i ll ha v e a b ox around i t.
#61 - 846 ND -752 1 -1 Page 12 of 25 5 .1 . Infra red se ttings Em i s sivi t y Set the em i ssivity v a l u e betw e e n 0.10 and 1. 00 using the l eft/r i g ht navi g ati o n buttons. Press i ng Funct i on Ke y 3 ( Tab l e ) g iv es a tab l e of emis si vity va l ues o f common mater i a l s f rom whic h a se l ect i on c an b e made.
#61 - 846 ND -752 1 -1 Page 13 of 25 5.2 . Measure men t op tions Th i s m en u en ab les th e s e l ect i on of opt i ons for temper atu r e measur e ment s . The s ymbo ls shown be low i nd ic at e t he i cons shown for F u n c t i o n K ey 1 w hen th e v ari o u s opt i ons ar e selected.
#61 - 846 ND -752 1 -1 Page 14 of 25 Isotherm s .Se l e c t “H igh ” , “L ow ” , or “H i g h & L ow ” i n ord er to hi g hli ght a re as of t he sc e ne w i th temp erature s with i n a h i gh (red) or l o w (b l ue) temp e rat ure band.
#61 - 846 ND -752 1 -1 Page 15 of 25 5.3 . Came ra set tings Capt i o n mode Se l e c t “ On” to enab l e the a dd i t i on of a t e xt c apt i on whe n s a vi ng an i m age. Opti o ns will then be d i s p layed when sav i ng an i m age, to be selected b y means of Func t ion Key 2 an d Fu n ct i on K e y 3.
#61 - 846 ND -752 1 -1 Page 16 of 25 5.4 . Audio sett in gs I m ager sound s Se l e c t “Off” to mute a ll a ud i b l e outp u ts. Vo i c e a n notat i on Se l ect “ In d ivi du al ” t o a dd a v o i ce me ssage to e a c h sa v ed i m age.
#61 - 846 ND -752 1 -1 Page 17 of 25 5. 5. Image browse r The saved i mag es are shown on t h e s creen w i th th e mo st recent ly s aved i mage first. Se l e c t t h e de sired i mag e by m eans of t he na vi gat i o n keys. To disp l ay t h e se l e c ted i m age pre s s Funct ion K ey 3.
#61 - 846 ND -752 1 -1 Page 18 of 25 5.7 . Langu age sele ction To sel ect a l a n guage mov e to the releva nt f l a g. When th e l a nguage i s hi gh l i g hte d p ress Func t ion Key 3 to select.
#61 - 846 ND -752 1 -1 Page 19 of 25 6. Add i ng ca ptions when sav ing images 6 .1 . Vo ic e mes sage When s aving an i mage with I nd ivi du al V oi ce A nnotat i on tur n ed o n, there i s the opt i on of sa vi ng a voice me ssage w i th ea c h i mage .
#61 - 846 ND -752 1 -1 Page 20 of 25 6.2 . Text caption s When s aving an i mage w i th C a pt i on Mode turned o n, there i s th e opt i on of a tta c hing a text capt i o n to e a c h imag e. Th e s cree n shot s be low describ e t h e pro c edu re : b ) Start Capt i on E n tr y c) Examp le o f a Capt i on.
#61 - 846 ND -752 1 -1 Page 21 of 25 Appendix A1. Emiss ivi ty Tables Emiss ivity Loo k-up T abl e s i n C amer a 1. 00 0.98 = Human skin 0.95 0.94 = Pai nt , oil 0.93 = Brick red 0.92 = Concrete 0.90 = Pl aned Oak W ood 0.85 0.80 0.79 = Ox i d i zed steel 0.
#61 - 846 ND -752 1 -1 Page 22 of 25 A2 . Full Icon List. Function K e y one Cursor one. Cursor two. Cursor th re e Cursor Four Alignment. Tracking. Area. Isotherm hi gh Isotherm l ow. Profil e hori zontal . Profil e ver tical. Al ar m hi g h. Al ar m low.
#61 - 846 ND -752 1 -1 Page 23 of 25 A3. Techn ica l spe cif ication Pe r formance Fiel d o f V i ew: 20° X 1 5° Focus: Man u a l Minimum F ocus: 30c m Spectra l respon s e : 8µm to 14µm Therma l Sens i t ivi ty: NETD 8 0 mK ( 0.08°C) @ 23° C amb i ent a nd 30°C scene t emperature.
#61 - 846 ND -752 1 -1 Page 24 of 25 • I sotherm s with temp era t ure d i fferenc e . • Voi c e and or te x t an n ota t ion . • I m age c aptur e ; t i me and dat e. • Vi sua l /aud i o a l arm for abo ve/ be low s e t tempe rature values. • P a l et te sele c t i o n.
#61 - 846 ND -752 1 -1 Page 25 of 25 Warran t y S t ate m ent Thi s tester is warrante d to t he original pur chaser agai n st d efects in material a nd workmanship fro two years from the d ate of pur c hase. Dur i n g t hi s warranty p eriod, IDEAL I N USTRI E S, INC.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il IDEAL INDUSTRIES HeatSeeker 160 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del IDEAL INDUSTRIES HeatSeeker 160 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso IDEAL INDUSTRIES HeatSeeker 160 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul IDEAL INDUSTRIES HeatSeeker 160 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il IDEAL INDUSTRIES HeatSeeker 160, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del IDEAL INDUSTRIES HeatSeeker 160.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il IDEAL INDUSTRIES HeatSeeker 160. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo IDEAL INDUSTRIES HeatSeeker 160 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.