IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-095 The Service Informatio n provides the fo llowing informa tion: • Precautions and safety inform ation • Specifications • Performance test pro.
TABLE OF CONTENTS Title Page # Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 Specifications 3 General Specification 3 Voltage Specifications 4 Resistance and C ontinuity Speci.
Page 1 Introduction Warning To avoid shock or injury, do not perform the verification tests or cali bration procedures described in this manual unless you are qualified to do so. The information provided in this document is for the use of qualified personnel only.
Page 2 SAFETY Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential h azards, use the product only as specified. CAUTION. These statements identify conditions or practices that cou ld result in damage to the equipment or other property.
Page 3 SPECIFICATIONS All specifications are warrant ed unless noted typical and appl y to the 61-095. Stated accuracies are at 23º C ± 5ºC at less than 80% relative humidity and without the battery indicator display ed. General specifications Characteristics Description LCD display digi ts 3 ½ Display count 2,000 Numeric update rat e 2.
Page 4 Measurement Characteristics Accuracy is ±(% reading + num ber of digits) at 2 3ºC ± 5º C, less than 80% R .H. Voltage Function Range Accuracy Overload protection V 600 Vrms ± (1.5%+ 3 dgt) 40Hz ~ 500Hz 600 Vrm s V 600 V ± (1% + 2 dgt) Input impedance: 1M Ω // less than 100pF.
Page 5 Physical and Environmental Characteristi cs Physical Characteristics Description Dimensi ons (H x W x D) 188mm x 66mm x 42mm Weight (with battery) 0.3Kg Environmental Characteristics Description Temperature operating 0 to + 50º C Non-Operating -20 to + 60º C Humidit y (operating) < 80% R.
Page 6 Required Equipment Required equipment is listed in Tab le B. If the recommended m odels are no t available, equ ipment with equivalent specifications m ay be used. Repairs or servicing s hould be perform ed only by qualified personnel. Table B.
Page 7 Basic Maintenance Warning To avoid shock, remove the te st leads and any input signal s before opening the case or replacing the battery or fuses. Opening the Meter Case Caution To avoid unintentional short circu it, always place the uncovered meter assembly on a protective surface.
Page 8 Performance Tests The following perform ance tests verify the complete ope rability of the meter and check the accuracy of each meter function against the meter’s specifications.
Page 9 Testing the Resistance Function To verify the accuracy of the re sistance function, do the following: 1. Connect the calib rator to V Ω and COM on the meter. 2. Turn the rotary switch to Ω . 3. Apply the inputs for step 1-4 i n Table 3. 4. Compare the meter display readings to the display reading s in Table 3.
Page 10 OK Figure 2 Top shows correct method; bo ttom shows incorrect method. Calibration Calibrate the meter once a year to ensure that it perform s according to specifications. Per fo rm ca lib ra tio n at an a mbi ent t empe ra tu re o f 23ºC ± 2ºC and relative humidity of 75% or less.
Form number TM61095 Rev 2 September 2002 Page 11 Figure 3 - Calibration Adjustment Points.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il IDEAL INDUSTRIES 61-095 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del IDEAL INDUSTRIES 61-095 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso IDEAL INDUSTRIES 61-095 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul IDEAL INDUSTRIES 61-095 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il IDEAL INDUSTRIES 61-095, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del IDEAL INDUSTRIES 61-095.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il IDEAL INDUSTRIES 61-095. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo IDEAL INDUSTRIES 61-095 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.