LinCon-8000 Compact Embedded Controller Hardware User’s Manual REV 1.0.0.0 2004/9/15 LinCon8000 Series Hardw are us er’s Manual, July/2003, v1.0 ----- 1.
Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original purchaser. Warning ICP DAS assumes no liability for damages consequent to the use of this product.
Table of Contents 1. INTRODUCTION ................................................................................ 4 1.1 P ACKAGE L IST & R ELEASE N OTE ...................................................................... 4 1.2 L IN C ON -8000 S ERIES .
1. Introduction 1.1 Package List & Release Note Package List : In addition to this m anual, the package includes the following items: z One set of LinCon8000 hardware z One Compact Flash Memory .
1.2 LinCon-8000 Series The LinCon-8000 is the flagship com pact embedded controller manufactured by ICPDAS. Its leading technology gives you all of the best features of both traditional PLCs and Linux capable P Cs. The LinCon-8000 syste m is powered by Linux and brings in the Linux programming style and skill into the world of PC- based PLC.
Model Description CPU Speed Embedded OS Slot Flash SDRAM Peripherals L-8031 L-8331 L-8731 Embedded Controller 206MHz Linux 0 3 7 32 Mbyte 64 Mbyte 10BaseT Ethernet Port × 1 VGA Port × 1 CF Slot × 1 USB × 1 PS/2 Keyboard × 1 PS/2 Mouse × 1 RS-232 × 1 RS-485 × 1 FRnet × 1(Option) LinCon8000 Series Hardw are us er’s Manual, July/2003, v1.
1.3 Contents of CD and CF memory card CD : LinCon8000 SDK Source code of demo programs Software User’s Manual References are given in ReadMe.
2. Hardware Information The LinCon-8000 Embedded Controller is com petitive with Industrial PCs i n performance, and is lower in price. The system provides VGA and PS/2 keyboard/mouse for local visualizat ion and management. User control programs and data can be saved in persistent storage via Compact Flash and USB interfaces.
2.2 Specifications Main Control Unit Intel Strong ARM CPU, 206MHz SRAM: 64M bytes Flash Memory: 32M bytes EEPROM: 16K bytes 64-bit hardware unique serial number Built-in Watchd.
3. Applications The following figure diagrams the genera l application area and structure of the LinCon-8000. Com2 is the standard RS232 interface, which can be connected via the modem or to the Com1 in the I-8000 C ontroller.
4. Quick S t art Step 1. Plug in your PS/2 keyboard and mouse. Step 2. Plug in your VGA monitor. Step 3. Connect the LinCon-8000 to the LAN Step 4. Insert the I-8K/87K series I/O modules into th e LinCon-8000 slots. Step 5. Connect the COM2 or the COM3 ports to your devices controlled by LinCon-8000.
5 Mechanical Information 5.1 Dimensions 5.2 Dimensions Rail Mounting 5.3 Wall Mounting LinCon8000 Series Hardw are us er’s Manual, July/2003, v1.0 ----- 12.
5.4 Controller cover For safety and the controller setting memo, the LinCon-8000 provides a main controller cover to protect the reset pus h button applied under the uncontrolled situation. And it also offers an expansion slot setting record area and others configuration memo areas.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il ICP DAS USA Compact Embedded Controller LinCon-8000 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del ICP DAS USA Compact Embedded Controller LinCon-8000 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso ICP DAS USA Compact Embedded Controller LinCon-8000 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul ICP DAS USA Compact Embedded Controller LinCon-8000 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il ICP DAS USA Compact Embedded Controller LinCon-8000, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del ICP DAS USA Compact Embedded Controller LinCon-8000.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il ICP DAS USA Compact Embedded Controller LinCon-8000. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo ICP DAS USA Compact Embedded Controller LinCon-8000 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.