Manuale d’uso / di manutenzione del prodotto RGSSFP del fabbricante hussman
Vai alla pagina of 18
/Chino RGSSFP Self Ser vice / F ood Prep Case Re v .0008 Installation & Operation Manual RGSSFP Self Ser vice / F ood Prep Case p/n IGFP-RGSSFP-0008 INST ALLA TION & OPERA TION GUIDE.
IGFP-RGSSFP-0008 2 /Chino A publication of Hussmann ® Chino 13770 Ramona A venue • Chino , California 91710 (909) 628-8942 F AX (909) 590-4910 (800) 395-9229 K eep this booklet with the case at all times for future r efer ence.
Rev.0 008 3 HUSSMANN CHINO PRODUCT CONTR OL The serial number and shipping date of all equipment has been recor ded in Hussmann’ s files for war ranty and re- placement part purposes.
IGFP-RGSSFP-0008 4 INST ALLING CONDENSA TE DRAIN Poorl y or improperl y installed condensate drains can se- riously interfer e with the operation of this refrigerator , and result in costl y maintenance and product losses. Please follow the r ecommendations listed belo w when installing condensate drains to insur e a proper installation: 1.
Rev.0 008 5 EXP ANSION V AL VE ADJUSTMENT Expansion valves m ust be adjusted to fully feed the e vapo- rator . Befor e attempting any adjustments, mak e sure the eva porator is either clear or very lightly cover ed with frost, and that the fixture is within 10 ° F of its expected operat- ing temperature.
IGFP-RGSSFP-0008 6 specified. Field wiring fr om the refrigeration contr ol panel to the mer chandisers is required f or refrigeration ther - mostats. Most component amper es are listed in the “Case Specs” section, but alwa ys check the serial plate.
Rev.0 008 7 Ammonia. Soap and hot water ar e not enough to kill this bacter ia. A sanitizing solution must be included with each c leaning pr o- cess to eliminate this bacteria. 1. Allow cases to come to r oom temperature 2. Scrub thor oughly , cleaning all surfaces, with soap and hot water .
IGFP-RGSSFP-0008 8 Maintenance ELECTRICAL PRECAUTIONS BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component This includes (but not limited to) Fans, Heaters, Thermostats, and Lights.
Rev.0 008 9 Specifications TEMPERATUREDISCHG. FAN SIZE DEFROST 115 V. ELECTRICAL CIRCUITS SELF CONTAINED UNIT DATA / SEE CROSS REF. BTU AVG AIR T-STAT/ TYPE & FREQ. SELF CONTAINED REQ’D EVAP PROD DISC VELOC CUT IN OF NUMBER & E E FANS STD. RECEP- LOW PRESSURE Length PER FT.
IGFP-RGSSFP-0008 10 Electrical Schematics Date: Project Title: Drawing N o.: Drawn By : Ass em bly: Draw ing Ti tle : Date: Hussmann Corporatio n, Int'l. 137 70 Ramona Avenue , Ch ino, C A. 91710 (909)- 590- 491 0 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Loc ation: Adrián E.
Rev.0 008 11 Date: Project Title: Drawing N o.: Drawn By : Assembly: Drawin g Title: Date: Hussmann Corporatio n, Int'l. 137 70 Ramona Avenue , Ch ino, C A. 91710 (909)- 590- 491 0 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Loc ation: Adrián E.
IGFP-RGSSFP-0008 12 Date: Project Title: Drawing N o.: Drawn By : Assembly: Drawin g Title: Date: Hussmann Corporatio n, Int'l. 137 70 Ramona Avenue , Ch ino, C A. 91710 (909)- 590- 491 0 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Loc ation: Adrián E.
Rev.0 008 13 Date: Project Title: Drawing N o.: Drawn By : Assembly: Drawin g Title: Date: Hussmann Corporatio n, Int'l. 137 70 Ramona Avenue , Ch ino, C A. 91710 (909)- 590- 491 0 Lic.#: 644406 Revisions: No. Descri ption: Checked By: By: File Loc ation: Adrián E.
IGFP-RGSSFP-0008 14.
Rev.0 008 15 APPENDIX A. – Temperature Guidlines The refrigerators should be operated according to the manufacturer’s published engineering specifications for entering air temperatures for specific equipment applications.
IGFP-RGSSFP-0008 16 only in Fahrenheit shall be accurate to 2 ° F. The thermometer should be checked for proper calibration. (It should read 32 ° F when the stem is immersed in an ice water bath).
Rev.0 008 17 Limited W arranty This warranty is made to the original user at the original installation site and is not transf erable . Hussmann mer chandisers are war ranted to be free fr om def ect i.
IGFP-RGSSFP-0008 18 The MODEL NAME and SERIAL NUMBER is required in or der to provide y ou with the corr ect parts and information f or your particular unit. They can be f ound on a small metal plate on the unit. Please note them below for futur e refer ence .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il hussman RGSSFP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del hussman RGSSFP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso hussman RGSSFP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul hussman RGSSFP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il hussman RGSSFP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del hussman RGSSFP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il hussman RGSSFP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo hussman RGSSFP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.