Owner’ s Manual File: 511/41251/book p. 1-15 Created: 5-28-98 mr Folder: 511/hunter/form 41251 Alt: 6-24-98 db Prints black 42999, 44050 SINCE 1 8 8 6 ® 511/41251/book p.
Other Quality Pr oducts fr om Hunter Fans Air Purifiers Humidifiers 511/41251/book p. 1-15 2/8/01 2:24 PM Page 2.
Installation Operation T able Of Contents Features 6 Remove Old Thermostat 8 Labeling Wires 10 Connecting Wires and Mounting Thermostat 14 System Selector Switches 14 Start-Up 16 Reviewing Current T e.
Read This Before Installing Thermostat IMPORT ANT 1 Read the entire installation section of this Owner’ s Manual thoroughly before you begin to install or operate your Hunter Thermostat. • Remove the mylar label from the display window . INST ALLA TION 2 All installation is normally performed at your thermostat.
TEMPERA TURE RANGE 6 Y our thermostat can be programmed between 40°F and 95°F (5°C and 35°C). However , it will display room temperatures from 32°F to 99°F (0°C to 37°C). POWER FAILURE 7 Whenever the main power is interrupted or fails, the battery power retains the programs and current time.
FIL TER HEA T OFF COOL AUTO FAN RESET Features (Model 42999) ■ Function Switch For tur ning on heating and cooling system. ■ Fan ON and AUTO Selector Switch.
Features (Model 44050) ■ Function Switch For tur ning on heating and cooling system. ■ Fan ON and AUTO Selector Switch. ■ Reset Button For resetting thermostat.
8-9 Installation This thermostat comes with two #8 slotted screws and two wall anchors for mounting. T o install your unit, you should have the following tools and materials. ■ Slotted screwdriver ■ Electric drill and 3/16" bit ■ Hammer ■ T wo 1.
Wall Mounting Plate Thermostat Cover Wall Mounting Plate Thermostat Cover TYPICAL HOME THERMOST A TS FIGURE 1 511/41251/book p. 1-15 2/8/01 2:24 PM Page 9.
10-11 Installation ■ Each wire coming from the wall to the existing thermostat is connected to a terminal point on that thermostat. Each of these terminal points is usually marked with a code letter as shown in T able A on page 9.
Wire Labeling RH G Y W RC RH RH RC RC G G Y Y W W and connect to thermostat T erminal shown then mark wire with label shown If the code letter on your existing thermostat is RH, R, VR or 4 24 Volt G o.
12-13 Installation NOTE: If your thermostat has one wire marked R or RH (4-wire system), then leave the jumper wire between the RH and RC terminals. Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH and RC terminals.
Snap open the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. Position wallplate on wall and pull existing wires through large opening. Then level for appearance. Mark holes for plastic anchors provided if existing holes do not line up with Hunter Thermostat holes.
14-15 Installation Connect Wires and Mount Thermostat Cover to Wall Plate Selector Switches The heating system selector and the F°/C° selector switches are located on the Printed Circuit Board. ■ Heating system selector The heating system selector is a switch on the Printed Circuit Board on the inside of the thermostat.
FIGURE 3 FIGURE 4 ■ Be sure to tighten the terminal screws securely , otherwise a loose wire could cause operational problems with your system or thermostat. ■ Push excess wire back into hole to prevent interference with mounting of the thermostat cover .
Programming ■ 68° indicates the current setting of the thermostat. ■ If pressed for more than 2 seconds, you will adjust the set- ting as explained below.
In this example we are raising the current set temperature of 68°F to a new setting of 72°F . Setting New T emperature ■ Press arrow to display current temperature setting.
Operations 72 . 7I . 70 . The Hunter Digital Thermostat measures and stores the amount of time the heating or air conditioning system operated. After 500 hours of usage, the word “FIL TER” will appear and flash on the display , reminding you to check or replace your system filter .
Note: Filter button works only when “FIL TER” is displayed on the display . If Filter button is pressed when “FIL TER” is not displayed, the inter nal counter will not reset. Y our thermostat is pre-programmed at the factory to cycle when the temperature rises 1° above or 1° below the temperature setting.
T roubleshooting Problem Solution SCRAMBLED OR DOUBLE DISPLAY (numbers over numbers NO DISPLA Y ENTIRE DISPLA Y DIMS AUTO/F AN DOES NOT COME ON HEA TING OR COOLING DOES NOT GO ON OR OFF 1. Remove clear mylar sticker . 1. Check battery connections and batteries.
ERRA TIC DISPLA Y IF UNIT CONTINUES TO OPERA TE IN OFF POSITION THERMOST A T READS , HI, LO PERMANENTL Y 1. Press the reset button once with a small pin and hold in for two seconds.
Wiring Diagrams 22-23 4-wire Heat/Cool System 5-wire Heat/Cool System THERMOST A T G W Y RH RC Heat Relay or V alv e Heat /Cool T ransformer Fan Relay Cool Contactor Jumper THERMOST A T G W Y RH RC Heat Relay or V alv e Heat T ransformer Fan Relay Cool Contactor Cool T ransformer 511/41251/book p.
Page 23 2-wire Heat Only 3-wire Cool Only 3-wire Heat Only THERMOST A T G W Y RH RC Heat Relay or V alv e Heat T ransformer THERMOST A T G W Y RH RC Heat Relay or V alv e Heat T ransformer Fan Relay THERMOST A T G W Y RH RC Cool Contactor Fa n Relay Cool T ransformer 511/41251/book p.
© 1996, Hunter Fan Company Form No. 41251, 5/98 ® HUNTER FAN COMP ANY 2500 FRISCO AVENUE MEMPHIS, TN 38114 511/41251/book p.16-24 2/8/01 2:57 PM Page 9.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hunter Fan 44050 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hunter Fan 44050 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hunter Fan 44050 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hunter Fan 44050 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hunter Fan 44050, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hunter Fan 44050.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hunter Fan 44050. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hunter Fan 44050 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.