HP 1 0000 G2 Ser i es R ac k Opti o ns Inst allati o n Gui de Abstract This document is for the person wh o installs racks and rack products. This procedure is performed onl y by trained personnel. HP assumes you are qualified in perfo rming installation s and trained in r ecognizing hazar ds in rack produc ts.
© Copyright 2008, 2013 He wlett- Packard Development Company, L.P. The information contained herei n is subject to change without notice. The only warranties for HP products and service s are set forth in the expres s warranty statements accompanyin g such products and services.
Contents 3 Con tents About this guide ........................................................................................................................... 7 Rack options installat ion guide ......................................................
Contents 4 Cable Management Tray kit ......................................................................................................... 36 About this device .......................................................................................
Contents 5 Important sa fety informat ion ...................................................................................................................... 76 Installing the 110V/22 0V Light .......................................................
Contents 6 Tie- Down kit ............................................................................................................................. 119 About this device ..............................................................................
About this guid e 7 Abo ut this guide Rack options installa tion guide This installation guide inc ludes the instructions for installing rack option kits that are compatible with the HP 10000 G2 Series Rack. For more informa tion, see the HP 10000 G2 Seri e s Rack User Guid e on the HP websit e ( http://www.
About this guid e 8 • Keyboard — The rack ke yboard requires installati on of a 1U keybo ard drawer rack option kit . • Monitor — The mon itor requires installatio n of a monitor/utility sh elf rack option kit unless yo u are using a rack - mountable flat - panel monitor.
Rack options 9 R ac k opti ons Ordering rack options HP provides seve ral rack option kits to complement or c omplete your ra ck solution. The followin g list is a sample of the many rac k option kits available . For information about ordering rack opt ion kits, see the HP website ( http://www.
Rack options 10 Rack option kit Part number Description Server/Utility S helf kit (on page 112 ) 253449 - B21 Holds rack comp onents inside the rack Side Panel kit (on page 116 ) AF054A Provid es encl.
100 Kilo Slidin g Shelf kit 11 1 00 K ilo Sliding She lf kit About this devic e The HP 100 Kilo Sl iding Shelf kit ena bles you to insta ll a sliding shelf in your rack mount system for placemen t and easy access to various components. Thi s option occupies 2Us of rac k space.
100 Kilo Slidin g Shelf kit 12 3. Extend the inner slid e s of the sliding rail un til the screw holes on t he sliding rail and the left ra il with fixed brackets are aligned . Gently push down on the sliding rail to loc k it into place. 4. Secure the rails togeth er with two M4 x 12 flat HD screws and M4 external washers.
100 Kilo Slidin g Shelf kit 13 1. Use the template on the front and rear of the rack f rame to mark the attachment points for the sliding shelf rail ass emblies, by measurin g from the top of the comp onent inst alled below the desired p osition for the slidin g shelf.
100 Kilo Slidin g Shelf kit 14 3. Secure the front of the left sliding shelf ra il assembly t o the front of th e rack frame with tw o M6 x 12 pan HD screws an d M6 externa l washers. 4. Repeat steps 2 an d 3 to install the right slid ing shelf rail assembly .
100 Kilo Sliding Shelf kit 15 4. Secure the slidin g shelf to each sliding rail usin g o ne M4 x 12 flat HD screw and M4 e xternal washer with one M4 nut on the inside of the shelf. 5. Attach the cable management arm to the sliding shelf with the f lat side of the cable management arm mounting bracket fl u sh with the sliding sh elf.
100 Kilo Slidin g Shelf kit 16 7. Secure the opposite end of t he cable management arm to the rack u sing two M6 x 12 pan HD s crews and M6 exter nal washers. Installation is complet e. Using the 100 Kilo Sli ding Shelf Use the handle on the front of the sliding shelf to slide it in and out of the r ack.
Airflow Optimi zation kit 17 A irflo w Optimi z ati on kit About this devic e The HP Airflow Op timization kit enable s you to install foam r ail gaskets in your HP 10000 G 2 Series 22U, 36U, 42U, and 47U 600 - mm (24 - in) wide racks and in to 42U 800 - mm (31 - in) wide racks to improv e separation between hot and cold aisles in the data cente r.
Airflow Optimi zation kit 18 3. Insert th e foam rai l gasket into the space between the 19 - in mounting rails and the vertical frame on both sides of the ra ck , with the closed cell si de of the foam r ail gasket faci ng the front of the rack. 4. Gently push the foam rail gasket into the space until it is flush with the vertical fr ame.
Airflow Optimi zation kit 19 3. Insert th e foam rail ga sket into the spa ce between th e racks with t he closed cell si de of the foam rail gasket facing the front of the rack. NOTE: Follow step s 1 through 3 t o install the foam rail gasket int o a rack that w ill be bayed using a 24 - in.
Airflow Optimi zation kit 20 5. (Optional) See the HP Baying Rack Option Kit for specific information on baying racks. Installing t he floor gasket 1. Depending on the size of your rack, cut the floor gasket at the perforation to reduce the length from 800 - mm (31 in) to 600 - m m (24 in).
Airflow Optimi zation kit 21 2. Remove the protective tape from the bottom edge of the floor gasket, and apply it to t he bottom of the rack with the adhesive strip facing the front of the rack.
Ballast kit 22 Ballas t kit About this devic e The HP Ballast k it provides ad ditional stability with single - rack installations. Kit contents Item Quant ity Ballast assembly 2 M6 screws 10 Cage nuts 10 Extra hardware might be included for your convenience.
Ballast kit 23 1. Install the two bot tom cage nuts using the c age nut insertion tool in cluded in your original rack hardware kit. 2. Count 16 holes up the rack, starting at the bottom cage nuts, and install the two top cage nuts using the cage nut insertion t ool.
Ballast kit 24 4. Insert th e M6 screws into one side of th e ballast a ssembly to secur e it to the rack . 5. Repeat step 4 to secure the other side of t he ballast assembly to t he rack.
Baying kit 25 Ba y ing kit About this devic e The HP Baying kit enables you to connect multiple racks of th e same series (HP 10 000 and 10000 G2 Series Racks), height, and depth. For example, two HP 10622 Racks can b e bayed together, as well a s two HP 10842 Racks.
Baying kit 26 1. Remove the fr ont and rear doors. 2. Remove the si de panels (if present bet ween the rac ks). 3. Position the ra cks side by side, ensur ing that the feet of t he racks are on solid floor ing (no cracks or openings).
Baying kit 27 If you bay HP racks with a re ar extension, you do not need to re move the rear extensions. Attach three baying brackets to the rear extensions using two T - 30 Torx screws in each bracket. 5. Bay any additional rack s. 6. Attach side panels to each end of the bayed rac ks, and reattach the front and rear doors.
Cable Manage ment Bracket kit 28 C able Manage men t Br ac k et kit About this devic e The HP Cable Manag ement Bracket kit ass ists with cable manage ment and is des igned for use with all HP racks.
Cable Manage ment Bracket kit 29 Installing the 1U cable management br acket 1. Insert one 1/4 turn plastic latch on either side of the 1U cable management bracket. 2. Align the 1U cable management bracket to the screw holes in the des ired location of the rack (1).
Cable Manage ment Bracket kit 30 Installing t he 2U cable manage ment bracket 1. Insert two 1/4 turn plastic latches on either side of the 2U cable management bracket. 2. Align the 2U cable management bracket to the screw holes in the des ired location of the rack (1).
Cable Manage ment Bracket kit 31 1. Place a cable manageme nt D - ring bracket clip ( 1) on a cable manageme nt D - ring bracket clamp (2 ). 2. Install the cable management D - ring bracket in a front mount (" Front mount " on page 31 ).
Cable Manage ment Bracket kit 32 3. Using a T - 25 Torx driver, insert one M6 x 16 - mm Torx screw to secure the cable manageme nt D - ring bracket to the rack (2). Side mount 1. Align the cable management D - ring bracket with the screw hole in the des ired location on the side of your rack (1).
Cable Manage ment Bracket kit 33 NOTE: The screw ho l es for the cross - ov er bracket are loc ated on the side o f the rear rack scr ew column, towards the inside of the rack. 2. Using a T - 25 Torx driver, insert two M5. 5 x 10 - mm Torx screw s on either side of t he cross - over bracket and secure to the rack fram e (2).
Cable Manage ment Bracket kit 34 Installing t he hook - and - lo op cabling straps Attach the clip to the rack in any of the fo llowing positions, then route and secure your cables with the hook - and - loop cabling stra ps.
Cable Manage ment Bracket kit 35 Installation is complet e..
Cable Manage ment Tray kit 36 C able Manage men t T r a y kit About this devic e The HP Cable Management Tray kit enable s you to attach cable management trays to the top of HP racks to improve cable manage ment.
Cable Manage ment Tray kit 37 Installing the cable management t ray 1. Attach the wire for the trough to the cable management tray. 2. Remove the t wo screws from the ra ck top.
Cable Manage ment Tray kit 38 3. Install the cable management tray on top of the rack, using the same two screws you removed in step 2. 4. Route the cables through the cable management tray.
Cable Manage ment Tray kit 39 5. Hook and slide the cov er into place. Installing the cable management inner and outer trays 1. Attach the cable management outer tray to the cable management tray.
Cable Manage ment Tray kit 40 2. Slide the inner tray into the outer tray, and adju st them to the desired length. 3. Attach the cable management inner tray to the cable management tray.
Cable Manage ment Tray kit 41 4. Route the cables through the cable management tray. Ground bonding stud location.
Fan (110V/ 220V) kit 42 F an ( 1 1 0V/ 2 20V) kit About this devic e The HP Fan (110V/220V) kit enhances the natural convec tion cooling by increasing rack airflow. Kit contents Item Quant ity Fan assembly 1 Power cord 2 Cable fastener 4 This kit might c ontain extra hardware fo r your convenience.
Fan (110V/ 220V) kit 43 3. Insert the fan assembly into the top of the rack and s ecure using the four T - 30 Torx screws from step 1. 4. Connect the power cord to the fan assembly.
Fan (110V/ 220V) kit 44 5. Insert the notched end of the tie wrap into a small hole in the rack rail and push the tie wrap in to lock it in place. Encircle the power cord with the ti e wrap by inserting the free end of the tie wrap into the hole on the other end of the tie wrap, pull ing the tie wrap tight, and cutting o ff excess leng th.
Filler Panel kit 45 F iller P anel kit About this devic e The HP Filler Panel kit ena bles you to cover open areas of t he rack to better cont rol airflow. Kit contents Item Quant ity 1U Filler panels — or — 1U Filler panels 10 100 This kit might c ontain extra hardware fo r your convenience.
Front Door kit 46 F r ont Doo r kit About this devic e The HP Front Door kit enables you to add a front door to your HP 10000 G2 Series rack. Y ou can also install this option kit on HP 10000 seri es racks of the same size.
Front Door kit 47 Installing the hinge brackets and lo ck catches The following ta bles indicate wher e the hinge brac kets and lock catches are to be mounted in a 36U or 42U front door installation. The distance is measured from the bottom of the rack to an indicate d hinge bracket or lock catch fastenin g hole.
Front Door kit 48 Installing the front door 1. Slide the bottom door hinge onto the hinge bracket o n the rack frame. 2. Lift the top hinge pin up, and slide the upper door hi nge into place. 3. Release the top hinge pin to secure the front door to the rack.
Ground Bonding k it 49 Gr ound Bon ding kit About this devic e The HP Ground Bondin g kit reduces the electr omagnetic emiss ions outside th e rack. These em issions are produced during normal operation of the elect ronic components within the rack.
Ground Bonding k it 50 a. Unlock and open the front door. b. Lift the top hinge pin up, and tilt the door away from the r ack. c. Lift the door up and out of the bottom hinge.
Ground Bonding k it 51 4. Insert a T - 25 Torx screw through the other end of the same grounding strap, and insert it in the hole on the rack front door. Tighten the screw. From the system chassis rail to the front door (with a grounding lug): 1. Insert a T - 25 Torx screw through one end of a 36.
Ground Bonding k it 52 3. Place an M8 int ernal serrated lock washer and an M8 hex nut ov er the grounding lug on the rig ht rear door and tighten. From the system chassis rail to the left rear door: 1. Insert a T - 25 Torx screw through the end of a 36.
Ground Bonding k it 53 4. Place an M8 internal serrated lock washer and an M8 hex nu t over the grounding lug on the cable access panel and tighten. From the system chassis rail to the rack top: 1. Insert a T - 25 Torx screw through on e end of a 15.24 - cm (6 - in) grounding strap, and secure it to the system chassi s rail.
Ground Bonding k it 54 4. Place an M8 internal serrat ed lock washer and an M8 hex nut over the grounding lug on the perforated panel and tighten. From the gro unding lu g on the perfor ated panel or fan kit to the ground ing lug on th e egress slot: 1.
Ground Bonding k it 55 From the rack to a building facility , contact your building superv isor for more informa tion. The following figure illu strates part s for this step.
Ground Bonding k it 56 5. Repeat steps 1 through 4 for the other bottom si de panel. From the middle syste m chassis rail to the middle side panel: 1. Connect a 36.83 - cm (14. 5 - in) and a 15.24 - cm (6 - in) grounding strap with connectors together.
Ground Bonding k it 57 3. Place the end of the 15.24 - cm (6 - in) grounding strap over the gro unding lug on t he top side panel. 4. Place an M8 internal serrat ed lock washer and an M8 hex nut ov er the grounding lug on the top side panel and tighten.
Ground Bonding k it 58 4. Place an M8 internal serrat ed lock washer and an M8 hex nut over the grounding lug on the perforated panel and tight en. From the grounding lug on the fan kit to the grounding lug on the egress slot: 1. Place one end of a 36.
Ground Bonding k it 59 Installing the ground bonding rack option kit on HP 10000 G2 Series Rack 150 - mm extension kits 1. Insert a T - 25 Torx screw through one end of a 15.24 - cm (6 - in) grounding strap, and secure it to the rear rack chass is. 2.
Ground Bonding k it 60 3. Place an M8 internal serrated lock washer and an M8 hex nut over the grounding lug on the extension kit and tighten. 4. Repeat the pr evious steps for the opposi te side of the r ack. From the ex tension ki t to the top ra ck side panel: 1.
Ground Bonding k it 61 3. Place an M8 internal serrated lock washer and an M8 hex nut over the grounding lug on the extension kit and tighten. From the side panel grounding lug to the bottom panel grounding lug: 1. Place the 36.83 - cm (14. 5 in) grounding strap over t he grounding lug on th e side panel of the extension kit.
Ground Bonding k it 62 3. Repeat the previous steps to secure the other e nd of the same grounding strap to the grounding l ug on the bottom panel of the extension kit.
Ground Bonding k it 63 4. Reinsert and tighten the front door panel screw. From the system chassis rail to the right rear door: 1. Insert a T - 25 Torx screw through the end of a 36. 83 - cm (14.5 - in) grounding strap, and secure it to the system chassi s rail.
Ground Bonding k it 64 3. Place an M8 internal serrated loc k washer and an M8 hex nut over the grounding lug on the lef t rear door and tighten. From the lef t rear doo r to the left re ar door cable access panel: 1. Place one end of a 15.24 - cm (6 - in) grounding str ap over the same grounding lug on the left r ear door.
Ground Bonding k it 65 3. Place an M8 inte rnal serrated loc k washer an d an M8 hex nut ove r the grounding strap on the r ack top and tighten. From the grounding lug on th e rack top to the grounding l ug on the perforated pane l: 1. Place one end of a 36.
Ground Bonding k it 66 3. Place the other en d of the same groundin g strap over the grounding lug on the egres s slot. 4. Pl ace an M8 internal serrat ed lock washer and an M8 hex nut over the grounding lug on the egress slot and tighten. From the rack to a building facility , contact your building superv isor for more informa tion.
Ground Bonding k it 67 Installing the ground bonding rack option kit on HP 10000 Series Rack side panels From the system chassis rail to the side panel: 1. Connect a 36.83 - cm (14. 5 - in) and a 15.24 - cm (6 - in) grounding strap with connectors together.
Ground Bonding k it 68 4. Place an M8 internal serrat ed lock washer and an M8 hex nut over the grounding lug on the perforated panel and tighten. From the grounding lug on the fan kit to the grounding lug on the egress slot: 1. Place one end of a 36.
Heavy Duty Stabilizer kit 69 H ea v y Duty Sta bili z er kit About this devic e The HP Heavy Duty Stabi lizer kit provides stabi lity and suppo rt and prevents possible tipping when you install, remove, or access equipment wit hin the rack. If you have a stand - alone rack with a single rack - mountable comp onent that ex c eeds 99.
Heavy Duty Stabilizer kit 70 b. Insert and partially tighten fou r M8 x16 - mm bolts with washers, sec uring the front stabilizer mount to the front caster plate. c. Insert and partially tighten two M8 x16 - mm bolts with wa shers on eac h side of the c aster plate ski rt, securing the front stabilizer mount to the front c aster plate.
Heavy Duty Stabilizer kit 71 2. Slide the rack in to its final location. 3. Raise the rack b y lowering the leve ling feet, raising th e casters approximately 6.
Hook - and - Loop Ca bling Strap C lip kit 72 Hook -and- L oop Ca bling S tr ap C lip kit About this devic e The HP Hook - and - Loop Cabling St rap Clip kit enables you to ad d hook - and - loop cabling strap c lips to manage your cable c onfigurations.
Hook - and - Loop Ca bling Strap Clip kit 73 Installing t he hook - and - lo op cabling strap cli ps Route and se cure your cabl es with the hook - and - loop cabling strap clips.
Hook - and - Loop Ca bling Strap Clip kit 74.
Hook - and - Loop Ca bling Strap Clip kit 75 Installation is complet e..
Light kit 76 L igh t kit About this devic e The HP Light kit enables you to add a light to the rack. Kit contents Item Quant ity 110V/220V l ight ass embly 1 Light cover 1 F14W/133 - T8 fluorescent lamp 1 Power cord (10 ft), C13 - C14 1 Mounting screw s 2 This kit might c ontain extra hardware fo r your convenience.
Light kit 77 Installing the 110V/220V Light 1. Remove the fl uorescent lamp cover. 2. Insert two screws, securing the light to the rack frame..
Light kit 78 3. Insert the fluorescent lamp pins int o the light socket (1) and ge ntly turn the fluorescent lamp tow ard the ra ck (2) until the lamp locks into place.
Light kit 79 Operating the 110V/220V Light Item Description Status 1 On Turns on the light. 2 Off Turns off the light. 3 Standby mode Turns on the lig ht when the rac k door is open, and turns off the light wh en the rack door is closed.
Light kit 80 WARNING: To reduce the risk of perso nal injury, fire, or damage to the equipment, do not exceed the reco mmended voltage for the r ack. HP 110V/220V light kit specifications Parameter Va.
Light kit 81 F14W/133- T8 flu orescent lam p specifi cations Electrical data* Nominal value M inimum Maximum Frequency 50 Hz — — Lamp nominal wattage 14 W — — Lamp rated wattage • Single operatio n • Series operation 14.0 W 30 W 12.8 W — 15.
Light kit 82 Color No Luminous Flux* Nominal Value CRI Color Temp ILCOS - Code Special colors • Activa • Gro -lux 172 gro 600 lm n/a 1A group n/a 6500 K n/a FD - 14/65/1A -E- G13 - 26 /360 Not for general l ighting purposes *At 50 - Hz operation, lam p aged for 100 h .
Mini Stabilizer k it 83 M ini S ta b ili z er kit About this devic e The HP Mini Stabilizer kit provides stability and support and pre vents possible t ipping when you install, remove, or access equipment within the rack. Kit contents Item Quant ity 600 - mm (23.
Mini Stabilizer k it 84 2. Insert and partially tighten four bolts with washers, securing the front foo t to the front caster plate. 3. If you are using the side feet, align the side fe et with the holes on the caster plate skir t and front foot.
Mini Stabilize r k it 85 4. Insert and partially tighten two bolts with washers, securing the side feet (if installed) and front foot to the caster plate skir t. 5. Tighten the bolts from step 2. 6. Tighten the bolts from step 4. Installation is complet e.
Rack Air Duct kit 86 R ac k A ir Duc t kit About this ki t The HP 10000 G2 Rac k Air Duct kit remov es warm air from the rack by chann eling the warm a ir into the data center ceiling return air plenum. The air duct s its on top of the rack, d irectly joined to the ceil ing plenum, preventing the warm air from entering the data center aisle .
Rack Air Duct kit 87 — Draw latch assembly ( 1) — Plastic push f astener (4) — 510 - mm foam gasket (2) — 520 - mm foam gasket (2) o Lower air duct assembl y (1) — M5.
Rack Air Duct kit 88 Installation video HP recommends wa tching the HP 10000 G2 Rack Air D uct Installation video. T he video provides a demonstration of installation strategies and techniques that might be he lpful while installing the air duct. To access the video: 1.
Rack Air Duct kit 89 3. Using a T - 30 Torx screwdr iver, remove th e M6 flathead screw securing each h inge bracket to the r ack (1), and then remove all of the hinge brackets from the rack (2). Retain the hinge bracke ts and screws for reinstallation.
Rack Air Duct kit 90 2. Remove the p erforated top plate of the ra ck (2). 3. Align the solid p late with the top of the ra ck (1). 4. Using a T - 30 Torx sc rewdriver, insert and tighten two of the four M - 12 bolts (from step 1) into the two corner holes at the front of rack (2) .
Rack Air Duct kit 91 3. Insert the right side plate into the rack, overlapping the left s ide plate, and set it on the lip of the rack frame (3). 4. Using a T - 25 Torx screwdriver, ins ert and tighten on e M5.5 self - tapping screw at the rear, right corner and one M5.
Rack Air Duct kit 92 3. Insert the airf low rail gasket into the space be tween the 19 - in mounting rails and the vertical frame on both sides of t he rack, with t he closed cell side of the airfl ow rail gas ket facing the front of the ra ck. 4. Gently push the airflow rail gasket into the space until it is flush with the vertical fra me .
Rack Air Duct kit 93 Installing the floor gasket 1. Cut the floor gasket at the perforation to reduce the length f rom 800 - mm (31 - in) to 600 - mm (24 - in). 2. Remove the p rotective tap e from the bottom edge of the floor gasket, and then apply it to the botto m of the rack with the adhesive strip facing the front of the rack.
Rack Air Duct kit 94 4. Assemble th e kits (" Assembling the kits " on page 98 ). 5. Install the kit assembly to the top of your rack . 6. Adjust the height of the kit. Removing the rear door s 1. Open the hinge bra ckets by pulling up the t op hinge pin and p ulling down the bottom hinge p in (1).
Rack Air Duct kit 95 4. Using a T - 25 Torx driver, remove th e upper and lower rear door lock catches by r emoving the two screws from each of th e upper and lower rear door lock catches. Reta in the door lock catche s and screws for r einstallat ion.
Rack Air Duct kit 96 d. Repeat step s a through c fo r the left - side assembly. 2. Install the top assembly of the rear exte nsion assembly. a. Align the top assemb ly with the insta lled side assembli es (1). b. Using a T - 25 Torx driver, insert and tighten two M6 machine screws into the rear screw holes (2).
Rack Air Duct kit 97 b. Using a T - 25 Torx driver, insert and tig hten four M6 machine screws into each corner hole (3). Installing the solid rear door s 1. Using a T - 25 Torx driver, insert and tighten two screws int o each of the upper and lower rear door loc k catches.
Rack Air Duct kit 98 b. Using a T - 30 Torx driver, insert and tighten one M 6 flathead screw to secure each hinge bracket to the rear exten sion assembly (2). 3. Lift the rear doors, aligning them with the hinge brackets on the re ar extension assembly (1) .
Rack Air Duct kit 99 c. Insert one M 5.5 self - tapping screw into each bottom corner of the assembly (3). d. Repeat step s a through c fo r the other side panel. 2. Assemble the upper duc t. a. Align the hooks of the side panels with the slots of the front and back panels (1).
Rack Air Duct kit 10 0 c. Insert two p lastic push fasteners int o the holes on both sid es of the asse mbly to secur e the draw - latch strap to the upper du ct assembly (2). d. Repeat steps a throug h c for the second draw - latch strap. 4. With the draw - latch straps in th e loose position, slide t he upper duct down over t he lower duct.
Rack Air Duct kit 10 1 6. Apply the foam gasketing to the top of the upper duct by peeling the adhesive backing and aligning the gasketing with the top edges of the upper du ct. Installing the kit assembly WARNING: The rack air duct weighs approx imately 22.
Rack Air Duct kit 10 2 5. Using a T - 30 Torx screwdriver, in sert and tighten two M - 12 bolts (from step 1) th rough the holes of the air duct assembly and into the two rear holes of the rack (3). Adjusting the kit After you have installed the air duct to the top of your rack: 1.
Rack Air Duct kit 10 3 b. Using an elect ric drill, drill one 2.38 - mm (3/32 - in) hole through the lower duct, in the location you marked. c. Insert one M 3.
Rack Air Duct kit 10 4 For more informa tion, see Baying kit (on page 25 )..
Rear Extension kit 105 R ear Extensi on kit About this devic e The HP Rear Extension kit enabl es you to add 200 - mm (7.87 - in) of depth to the rear of the HP 10000 Series and HP 10000 G2 Series r acks. The HP Rear Extension kit only fits the 600 - mm (23.
Rear Extension kit 106 2. Lift the rea r doors off the h inge bracket s, and then remove t he doors from the rack (2). 3. Using a T - 30 Torx screwdr iver, remove th e M6 flathead screw securing each h inge bracket to the r ack (1), and then remove all of the hinge brackets from the rack (2).
Rear Extension kit 107 4. U sing a T - 25 Torx drive r, remove the upp er and lower rear door lo ck catches by removin g the two screws from e ach of the upp er and lower r ear door lock catch es. Retain the door loc k catches and screws for r einstallat ion.
Rear Extension kit 108 a. Align the top assemb ly with the insta lled side assembli es (1). b. Using a T - 25 Torx driver, insert and tig hten two M6 machine screws into the rear screw holes (2). c. Using a T - 25 Torx driver, insert and tighte n two M6 machine screws into the front screw hole s ( 3).
Rear Extension kit 109 4. Insert th e filler pan els into the side an d top assemb lies. Installing t he rear doors 1. Using a T - 25 Torx driver, insert and tighten two screws int o each of the upper and lower rear door loc k catches. 2. Install the hinges brackets.
Rear Extension kit 110 b. Using a T - 30 Torx driver, insert and tighten one M 6 flathead screw to secure each hinge bracket to the rear exten sion assembly (2). 3. Lift the rear doors, aligning them with the hinge brackets on the re ar extension assembly (1).
Rear Extens ion k it 111 3. Using a T -2 5 Torx driver, insert a nd tighten one M 5.5 self - tapping screw into each side of the bracke t to secure the cable management bracket to the rack frame and extens ion kit (2).
Server/Utility S helf kit 112 Se r v er/Utility Shelf kit About this devic e The HP Server/Utility Shelf kit enables you to install a convenient shelf in your rack - mount system.
Server/Utility S helf kit 113 1. Align the cage nuts with the square - rail perforations o n the front of t he shelf. 2. Use the cage nut insertion tool (not included) to secu re each cage nut to the shelf. a. Hook the bottom lip of the cage nut in the s quare - rail perforation.
Server/Utility S helf kit 114 5. Align each cage nut assembly with the mounting holes on the inside front of the rack. 6. Secure the shelf to t he rack with two M6 scr ews using a Phillip s screwdriver.
Server/Utility S helf kit 115 7. Secure serv ers to the shel f using the quick - release ti e - down s traps. Installation is complet e..
Side Panel kit 116 Si de P anel kit About this devic e The HP Side P anel kit enabl es you to attach side panels to H P 10000 G2 Seri es Racks. Kit contents Item Quant ity Top side panel 2 Middle side panel 2 Bottom side pan el 2 Key 2 This kit might c ontain extra hardware fo r your convenience.
Side Panel kit 117 Installing the side panels 1. Install the top and bottom side panel by sliding the brackets on the side panel behind the tabs on the rack frame.
Side Panel kit 118 2. Install the midd le side panel by locking th e side panel locks, sec uring it to the rack. 3. Repeat steps 1 and 2 for the other side o f the rack.
Tie - Down kit 119 Tie - Do w n kit About this devic e The HP 10000 G2 S eries Rack Tie - down Kit enables you to s ecure HP 10000 G2 Series Racks to th e floor. This kit is for all 10000 G 2 Series Racks except for R ack SKUs AF092A and AF 094A. A separate tie - down kit is used excl usively for t he 1200 full fra me racks.
Tie - Down kit 120 3. Insert and partially tighten four bolts wi th washers, securing the front tie - down to the front caster plate. 4. Align the rear t ie - down with the holes on t he rear caster plate (1) .
Tie - Down kit 121 Securing the rack to the f loor The following illustration indicates where to drill the holes to secure the rack to the floor. The distances are measured from the holes on the tie - downs. Have your build ing structural eng ineer drill the hol es.
Tie - Down kit 122 1. Adjust the leveling feet on the rack so that t he full weight of the rack rests on the l eveling feet. 2. Align the front tie - down with the holes on the front caster plate. 3. Insert and then partially tighten four bolts with washers, securing the front tie - down to the front caster plate.
Tie - Down kit 123 Securing the 1200 mm full frame rack to the floor The following illu stration indicate s where to drill the h oles to secure the 1200 mm full frame rac k to the floor . The distances are measured from the holes on the tie - downs. Have your bu ilding structural engineer drill the holes.
Vertical PD U Mounting kit 124 V ertical P DU Mounting kit About this devic e The HP Vertical PDU Mounting kit allows HP PD U vertical models to be mounted in HP 10000 G2 Series Racks and in the HP V142 Rack.
Vertical PD U Mounting kit 125 HP monitored PDU 2. Install the PDU. The installation is complete..
Electrostatic dis charge 126 Electr os tati c disc har ge Preventing elec trostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up th e system or handling parts.
Support and other resources 127 Suppo r t and other r es our ces Before you contac t HP Be sure to have the foll owing informati on available befor e you call HP: • Active Health S ystem log (HP ProLiant G en8 or later products) Download and have av ailable an Active Health System log f or 3 days befo re the failure was detected.
Acronyms and ab breviations 128 A c r on y ms and abbr e v iati ons KVM keyboard, video, and mo use PDU power distribution unit RKM rackmount keyboar d monitor TMRA recommended ambient ope rating temp.
Documentation feedback 129 Doc ument ati on f eedbac k HP is committed to pro viding documentation that mee ts your needs. To help us improve th e documentation, send any erro rs, suggestion s, or comments to Documentation Feedback ( mailto:docsfeedback@hp.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il HP (Hewlett-Packard) AF074A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del HP (Hewlett-Packard) AF074A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso HP (Hewlett-Packard) AF074A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul HP (Hewlett-Packard) AF074A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il HP (Hewlett-Packard) AF074A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del HP (Hewlett-Packard) AF074A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il HP (Hewlett-Packard) AF074A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo HP (Hewlett-Packard) AF074A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.