Manuale d’uso / di manutenzione del prodotto 3572 del fabbricante American Standard
Vai alla pagina of 16
754063-100 Rev. B 1 THANK YOU... for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The Air Massage System is completely assembled with air pump, motor, lights, and system piping. All you need to finish the installation are your selected fittings and electrical connections for an Air Massage System.
754063-100 Rev. B TABLE OF CONTENTS: Cover ................................................................................................Page 1 Table of Contents ..............................................................................Page Safety Instructions Notice.
754063-100 Rev. B 3 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS! ! ! ! ! ! ! WARNING: Risk of personal injury. Do not permit children to use this bathtub without adult supervision. WARNING: Risk of electric shock. Do not permit electrical appliances near any bathtub when bathtub contains water.
4 754063-100 Rev. B ELLISSE OVAL MODEL 2709 AIR BATH C/L FOR SPOUT & VALVES FOR HAND SPRAY FITTINGS DECK EDGE OF FITTINGS DECK 35-3/4 (908mm) TO END OF TUB 1-1/2 (38mm) 1-1/2 (38mm) 1-1/2 (38mm) 2.
754063-100 Rev. B 5 GREEN TEA™ 6' x 36" MODEL 3573 AIR BATH GREEN TEA™ 5' x 42" MODEL 3574 AIR BATH ROUGHING-IN REFERENCES TOP VIEW END VIEW TOP VIEW END VIEW TOP VIEW END VIEW.
6 754063-100 Rev. B ROUGHING-IN REFERENCES GENERAL SPECIFICATIONS FOR 2748 AIR MASSAGE SYSTEM 59-1/2 x 41-5/8 x 23 In. (1511 x 1057 x 584mm) 110 Lbs. (50 Kg.) 611 Lbs. (278 Kg.) 60 Gal. (227 L) 34 x 24 In. (864 x 610mm) 52 x 31 In. (1321 x 1321mm) 12-1/2 In.
754063-100 Rev. B 7 60-1/4" 35" 36" 1" 5-1/" 34-1/" 1530mm mm 14mm 43mm 146mm 76mm 66-1/4" 35" 36" 1" 64-1/&quo.
754063-100 Rev. B All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. WARNING: When using electrical products, basic precautions should always be observed, including the following: 1.
754063-100 Rev. B Please note that care must be taken to protect the surface of the tub during all aspects of the installation. Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result. 1. Install the tub per the installation instructions provided with the unit.
10 754063-100 Rev. B DRAIN CONNECTION 1. Remove and identify all drain components as defined in air bath drain illustration. 2. Find 1" schedule 40 PVC pipe, see pipe chart, HORIZONTAL DRAIN PIPE . Mark as "horizontal pipe", drain to elbow section.
754063-100 Rev. B 11 DRAIN CONNECTION continued... 8. Have assistant take drain assembly from step 6 and place over back surface of drain hole to engage the metal strainer bolt. Secure plastic drain base to metal strainer in drain opening using nut driver shaft.
1 754063-100 Rev. B DRAIN CONNECTION continued... 12. Apply PVC cement to Horizontal Drain Pipe PVC and assemble to 0 degree elbow. 13. Dry fit Vertical Drain Pipe PVC into overflow assembly, then insert into elbow, WITHOUT PVC GLUE to align drain and overflow to bath.
754063-100 Rev. B 13 DRAIN CONNECTION continued... 18. Tighten chrome overflow retainer onto drain overflow assembly pipe per photo Q below. 19. Align flat on drain actuator shaft with corresponding flat in chrome metal overflow escutcheon and tighten set screw to fix overflow escutcheon in place per photos R and S .
14 754063-100 Rev. B POST INSTALLATION CLEAN-UP Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use wire brushes or any other metal implement on bath surface. Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent.
754063-100 Rev. B 15 REMOTE BLOWER LOCATION OPTION IMPORTANT! It is not necessary that the blower motor be relocated. This option is provided for the case that a particular installation makes this effort practical.
16 754063-100 Rev. B By Mail: American Standard Inc. P.O. Box 65 West Caldwell, N.J. 07007 Attention: Customer Care Center AS America, Inc. Limited Lifetime Warranty for Premium Acrylic Air Baths AS America, Inc.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il American Standard 3572 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del American Standard 3572 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso American Standard 3572 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul American Standard 3572 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il American Standard 3572, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del American Standard 3572.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il American Standard 3572. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo American Standard 3572 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.