Manuale d’uso / di manutenzione del prodotto ROX-20TA-U del fabbricante Hoshizaki
Vai alla pagina of 36
N O . U8AA-554 ISSUED: DEC. 29, 2000 REVISED: SER VICE MANUAL HOSHIZAKI HOSHIZAKI HOSHIZAKI HOSHIZAKI HOSHIZAKI WATER ELECTROLYZER WATER ELECTROLYZER WATER ELECTROLYZER WATER ELECTROLYZER WATER ELECTR.
U8AA5540012 CONTENTS P AGE I. GENERAL INFORMA TION -------------------------------------------------------------------------- 1 1. SAFETY INSTRUCTIONS ------------------------------------------------------------------------ 1 2.
1 U8AA5540012 I. GENERAL INFORMA TION 1. SAFETY INSTRUCTIONS The following instructions contain important safety precautions and should be strictly observed.
2 U8AA5540012 10. Always ask the user to keep children away from the work area. They may be injured by tools or disassembled products. CAUTION 1. After servicing, be sure to check for water leaks from the water supply and drain lines to prevent wetting the surrounding properties.
3 U8AA5540012 2. PRODUCT INFORMA TION [a] FEA TURES 1) Space saving The compact unit (W280 x D400 x H310 mm) allows for installation under sink. 2) V arious optional parts available Remote Controller: Makes the dispensing section remotely operable at hand.
4 U8AA5540012 3. DIMENSIONS/CONNECTIONS Unit: inch (mm).
5 U8AA5540012 4. FEA TURES OF STRONG ACID W A TER Electrolyzed water (electrolyzed functional water) is a solution with useful functions caused by electrolyzation of thin salt water or tap water .
6 U8AA5540012 5. PRINCIPLE OF STRONG ACID W A TER GENERA TION Strong acid water is generated at the anode inside the Electrolytic Cell where the membrane divides the anode and cathode, by electrolyzation of 0.1% or less salt water . See the figure below .
7 U8AA5540012 II. CONSTRUCTION 1. GENERAL [1] Display Panel See “3. DISPLA Y P ANEL“. [2] Lamp Board Board with lamps indicating unit status. [3] Control Box See “4. CONTROL BOX”. [4] Flow Switching V alve Changes the flow direction of electrolyzed water .
8 U8AA5540012 [13] Door Provided with Door Lock. [14] Door Lock Locks the Door . [15] Control Panel See “2. CONTROL P ANEL”. [16] Acid W ater Outlet Dispenses acid water during the normal operation and alkaline water during the flushing process.
9 U8AA5540012 2. CONTROL P ANEL [1] Display Window Displays the operation time, amperage or voltage during the normal operation and error codes in case of trouble. [2] Operation T ime Lamp Display Window displays operation time (h) when this lamp is on.
10 U8AA5540012 [1] Dispense Button Starts and stops dispensing electrolyzed water . [2] Dispensing Lamp (Green) Indicates that the unit is producing water . [3] Ready Lamp (Green) Flashes until the desired settings are achieved and stays on when the unit is dispensing electrolyzed water .
11 U8AA5540012 4. CONTROL BOX [1] Switching Regulator Supplies power to start the Programmable Controller , etc. [2] Noise Board Board to remove noise in the unit. [3] Current Sensor Reads amperage in the Electrolytic Cell. [4] W ater Level Sensor Board Board to control the W ater Level Sensor .
12 U8AA5540012 5. REMOTE CONTROLLER (OPTION) [1] Ready Lamp (Green) Flashes until the desired settings are achieved and stays on when the unit is dispensing electrolyzed water . [2] Add Salt W ater Lamp (Red) Indicates that the Salt W ater T ank level is too low .
13 U8AA5540012 III. OPERA TING INSTRUCTIONS 1. FUNCTIONS AND ADJUSTMENT OF SET ITEMS The water electrolyzer is provided with the nine set items of the following functions: No. A1 A2 A3 A4 A5 A6 A7 A8 A9 Set Items Cell Lifecycle (h) 3000 - 8000 Amperage (A) 0.
14 U8AA5540012 and turn the volume while watching the Display Window on the Control Panel. 2. Do not change the amperage and voltage extremely from the initial set values.
15 U8AA5540012 7) Release the Set Button. 8) Check that the Display Window reads “A 1”, which means the unit is in the adjust mode No. 1. 9) Push the Flush Button one time. The Display Window will flash the present cell lifecycle (factory setting: 3000 h).
16 U8AA5540012 A2: Amperage 1) Follow the steps 1) to 8) in “A1: Cell Lifecycle” to show “A 1” in the Display Window on the Control Panel. 2) Push the Set Button one time to show “A 2” in the Display Window . 3) Push the Flush Button one time.
17 U8AA5540012 7) While pushing the Set Button, press the Display Button one time. 8) Check that the Display Window reads “CHE.”, which means the unit is in the check mode. 9) While pushing the Set Button, press the Display Button one more time. 10) Check that the Display Window reads “Nor .
18 U8AA5540012 7) While pushing the Set Button, press the Display Button one time. 8) Check that the Display Window reads “CHE.”, which means the unit is in the check mode. 9) While pushing the Set Button, press the Display Button one more time. 10) Check that the Display Window reads “Nor .
19 U8AA5540012 T o cancel the adjustment, press the Display Button and Flush Button together to show “A 6” in the Display Window . 6) When the Display Window shows “A 6”, keep on pushing the Set Button. Check that the Display Window reads “AdJ.
20 U8AA5540012 6) When the Display Window shows “A 8”, keep on pushing the Set Button. Check that the Display Window reads “AdJ.” 7) While pushing the Set Button, press the Display Button one time. 8) Check that the Display Window reads “CHE.
21 U8AA5540012 2. FUNCTIONS AND ADJUSTMENT OF CHECK ITEMS The water electrolyzer is provided with the ten check items of the following functions: No. C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 Check Items Output .
22 U8AA5540012 5) Keep on pushing the Set Button, and press the Display Button one time. 6) Check that the Display Window reads “AdJ.”, which means the unit is in the adjust mode. Lighting Flashing Lighting Flashing 7) Keep on pushing the Set Button, and press the Display Button one more time.
23 U8AA5540012 Relay X3 Magnet Switch Relay X1 Gear Motor W ater V alve None Pulse signal to Metering Pump Output to DC power supply CNT-TOG 12) When the desired check item code is displayed, push the Flush Button one time. The Display Window will show the present check item information.
24 U8AA5540012 3. OPERA TION FLOW CHART Operation Press Display Button. Keep on pushing Set Button, and press Display Button. Press Flush Button. Press Set Button. For A7, keep on pushing it for 10 sec. Press Display Button and Flush Button together .
25 U8AA5540012 IV . TECHNICAL INFORMA TION 1. W A TER CIRCUIT Pressure Gauge Filter Wa t e r Supply Pressure Reducing V alve (Accessory) W ater Electrolyzer (ROX-20T A-U) Pressure Reducing V alve (2.
2. WIRING DIAGRAM 26 U8AA5540012.
27 U8AA5540012 3. PERFORMANCE DA T A The following graph shows the electrode performance curve. The electrode life cycle depends on the free chlorine concentration as well as the raw water quality . T o optimize the electrolyzed water , we recommend the Electrolytic Cell should be replaced every 3,000 hours of operation.
28 U8AA5540012 W ater T emperature: 25°C * The above data depends on the water temperature and water quality . W ater T emperature: 25°C * The above data depends on the water temperature and water quality .
29 U8AA5540012 V . SER VICE INFORMA TION 1. MAINTENANCE/INSPECTION Check the following items during maintenance or inspection in normal condition. If any of them is found abnormal or defective, repair , replace or adjust it properly .
30 U8AA5540012 [a] Acid W ater pH, Alkaline W ater pH [No. 1, 2] Always use the accessory pH test paper or a pH tester on the market to check pH. Carefully read the instructions provided with the test paper or tester , and use it properly . [b] A vailable Chlorine Concentration (Acid) [No.
31 U8AA5540012 The water softener also needs salt for regeneration. Always add a proper amount of salt into the water softener . Give the user suf ficient instructions to add salt periodically .
32 U8AA5540012 Lamp Service Call Service Call Code E42 E43 E51 E52 Problem Metering pump stroke speed exceeds 360spm for 60 sec. Metering pump stroke speed does not exceed 10spm for 60 sec.
33 U8AA5540012 Lamp Service Call Code E61 E62 E65 Problem Flow switching valve direction microswitch turns ON and OFF 5 times in 2 min. Programmable controller outputs to flow switching valve gear motor for 20 sec. After gear motor stops, location microswitch turns ON.
HOSHIZAKI ELECTRIC CO., L TD. 3-16 MINAMIY AKA T A, SAKAE, TOYOAKE, AICHI 470-1 194 JAP AN PHONE: 0562-97-21 1 1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hoshizaki ROX-20TA-U è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hoshizaki ROX-20TA-U - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hoshizaki ROX-20TA-U imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hoshizaki ROX-20TA-U ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hoshizaki ROX-20TA-U, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hoshizaki ROX-20TA-U.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hoshizaki ROX-20TA-U. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hoshizaki ROX-20TA-U insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.