Manuale d’uso / di manutenzione del prodotto 252TS del fabbricante Hobart Welding Products
Vai alla pagina of 32
302, And 252TS Models Cyber Pro Pro cesses Descrip ti on MIG (GMA W) W elding Flux Cored (FCA W) W elding Arc Welding Power Source OM -259 177 743K September 2000.
Hobart W elders manufactures a full line of welders and welding related equipment. For information on other quality Hobart products, contact your local Hobart distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-877-Hobart1.
The following terms are used interchangeably throughout this manual: TIG = GT AW Stick = SMAW W ARNING T ABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-259 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_4/98 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message.
OM-259 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.
OM-259 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-259 Page 4 1-5. EMF Information Considerations About W elding And The Effects Of Low Frequency Electric A n d M a g netic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields.
OM-259 Page 5 SECTION 1 – CONSIGNES DE SECURITE – LIRE A V ANT UTILISA TION som _nd_fre 4/98 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette proc é dure pr é sente des risques de danger ! Ceux-ci sont identifi é s par des symboles adjacents aux directives.
OM-259 Page 6 Le rayonnement de l ’ arc du proc é d é de soudage g é n è re des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des br û lures dans les yeux et sur la peau. Des é tincelles sont projet é es pendant le soudage.
OM-259 Page 7 1-3. Dangers suppl é mentaires en relation avec l ’ installation, le fonctionnement et la maintenance Risque D ’ INCENDIE OU D ’ EXPLOSION. D Ne pas placer l ’ appareil sur , au-dessus ou à proxi- mit é de surfaces infllammables.
OM-259 Page 8 1-4. Principales normes de s é curit é Safety in W elding and Cutting, norme ANSI Z49.1, de l ’ American Wel- ding Society , 550 N.W . Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.
OM-259 Page 9 SECTION 2 – INST ALLA TION 2-1. Specifications Rated Open- Circuit Amperes Input at Rated Load Output, 50 or 60 Hz, Three-Phase Model Rated W elding Output Circuit V oltage Range DC 200 V 220 V 230 V 380 V 400 V 440 V 460 V 520 V 575 V KV A KW 250 Amp 250 A @ 35 V olts DC, 100% Duty Cycle 14 – 44 34.
OM-259 Page 10 2-3. V olt-Ampere Curves va_curve1 4/95 – SA-180 902 / SA-180 901-B V olt-ampere curves show mini- mum and maximum voltage and amperage output capabilities of unit. Curves of other settings fall be- tween curves shown. A. 250 Ampere Models B.
OM-259 Page 1 1 2-4. Dimensions And Weights C C Dimensions E D Height 27-1/4 in (692 mm) 4 Holes Width 22-1/4 in (565 mm) Depth 28-1/4 in (717 mm) A 27-1/2 in (698 mm) A B 3/4 in (19 mm) A C 21-1/8 in (537 mm) D 1-1/8 in (29 mm) E 7/16 in (1 1 mm) Dia W eight ST-801 530 B 320 lb (145 kg) 2-5.
OM-259 Page 12 2-6. T ypical MIG Process Connections Using A Constant Speed Wire Feeder Y W eld current can damage electronic parts in vehicles. Disconnect both battery cables before welding on a vehicle. Pl ace work clamp as close t o the weld as possible.
OM-259 Page 13 2-8. Slope Selection (250 Ampere Model) Ref. ST-801 518-A 1 Slope Connection Label 2 T apped Reactor AC-Z And Slope Coils T apped reactor AC-Z is factory con- nected to slope tap 8 which is suit- able for most GMAW applications. AC-Z controls the inductance applied to the weld current.
OM-259 Page 14 2-9. Inductance Selection (300 Ampere Models) 1 Stabilizer Z T apped stabilizer Z is factory connected to the stabilizer tap which suits most GMAW applications. Stabilizer Z controls the inductance applied to the weld current. T o in- crease inductance and wet out the weld puddle, connect to stabilizer Z ending.
OM-259 Page 15 2-10. W eld Output T erminals And Selecting Cable Sizes Y ARC WELDING can cause Electromagnetic Interference. T o reduce possible interference, keep weld cables as short as possible, close together , and down low , such as on the floor .
OM-259 Page 16 2-12. Connecting T o 1 15 V olts AC Duplex Receptacle Ref. ST-801 380-B 1 1 15 V 15 A AC Receptacle RC9 Power i s shared between RC9 a n d remote 14 receptacle RC8. 2 Circuit Breaker CB1 3 Circuit Breaker CB2 CB 1 protects 1 15 volts ac portion of RC8 and RC9 from overload.
OM-259 Page 17 4 2-14. Placing Jumper Links And Connecting Input Power ST-801 382 Check input voltage available at site. 1 Jumper Link Label Check label – only one is on unit. 2 Jumper Link Move jumper links to match input voltage, and label on unit.
OM-259 Page 18 SECTION 3 – OPERA TION 3-1. Controls Ref. ST-801 380-B 1 Power Switch 2 Pilot Light Light is on when power is On. 3 Preset Indicator Light When light is on, the voltmeter displays preset welding voltage as selected by the V oltage Adjustment control.
OM-259 Page 19 4-2. T roubleshooting T rouble Remedy Completely inoperative; fan does not run. Place line disconnect switch in the On position. Check and replace open line fuse(s) (see Section 2-13). Check for proper jumper link positions (see Section 2-14).
OM-259 Page 20 SECTION 5 – ELECTRICAL DIAGRAMS SB-183 958-A Figure 5-1. Circuit Diagram For 250 Ampere Model For Primary Circuit Diagram Portion, refer to Circuit Diagram located inside the wrapper of the welding power source. SB-183 959 Figure 5-2.
OM-259 Page 21 Notes.
OM-259 Page 22 SECTION 6 – P ARTS LIST Figure 6-1. Complete Assembly 801 383-F 1 2 3 4 5 6 7 11 12 13 14 15 16 Fig 6-3 – 17 18 19 1 20 22 23 24 25 26 27 21 Fig 6-2 – 28 30 31 32 29 33 34 35 36 8.
OM-259 Page 23 Quantity Description Part No. Dia. Mkgs. Item No. Figure 6-1. Complete Assembly 1 134 464 LABEL, warning general 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 179 430 P ANEL, side 2 .
OM-259 Page 24 Quantity Description Part No. Dia. Mkgs. Item No. Figure 6-1. Complete Assembly (Continued) 36 180 666 BRACKET , mtg PC board 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-259 Page 25 Figure 6-2. Panel, Front w/Components Ref. 802 497 2 1 3 4 5 5 2 7 9 10 11 12 14 15 16 17 18 19 20 21 6 8 13 22.
OM-259 Page 26 Figure 6-3. Rectifier Assembly Ref. 802 497 1 3 2 4 9 5 6 8 10 7 Figure 6-3. Panel, Front w/Components (Figure 6-1 Item 17) Description Part No. Dia. Mkgs. Item No. 1 022 285 MOUNTING BOARD, rectifier 2 . . . . . . . . . . . . . . . . .
Warranty Questions? Call 1-877-HOBART1 for your local Hobart distributor. hobart standard 7/00 Service Y o u always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor or call 1-800-332-3281.
PRINTED IN USA 2000 Hobart Welding Products. 1/00 Hoba rt We lding Produc ts An I l li noi s T ool Works Com pany 600 West Main St reet Troy , O H 45373 US A For Technical A ssistan ce: Call1-800-.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hobart Welding Products 252TS è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hobart Welding Products 252TS - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hobart Welding Products 252TS imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hobart Welding Products 252TS ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hobart Welding Products 252TS, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hobart Welding Products 252TS.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hobart Welding Products 252TS. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hobart Welding Products 252TS insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.