AM SELECT DISHW ASHERS MODELS AM15 ML-130038 AM15F ML-130045 AM15T ML-130039 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com FORM 35320 Rev.
– 2 – POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. IMPORT ANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNIT(S) AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.
– 3 – TABLE OF CONTENTS GENERAL 4 INSTALLATION 5 UNPACKING 5 INSTALLATION CODES 5 LOCATION 5 CORNER INSTALLATION 6 WATER REQUIREMENTS 7 PLUMBING CONNECTIONS 8 DRAIN CONNECTION 8 WATER CONNECTION 8.
– 4 – Installation, Operation, and Care of AM SELECT DISHW ASHERS SA VE THESE INSTRUCTIONS GENERAL Models AM15 and AM15T dishwashers can be configured for straight through or corner operation. Model AM15F is configured for front loading. AM15 and AM15T dishwashers are shipped from the factory in straight-through configuration.
– 5 – INST ALLA TION UNPACKING Immediately after unpacking the dishwasher, check for possible shipping damage. If this machine is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
– 6 – CORNER INSTALLATION Before placing the dishwasher in its operating location, check machine configuration. If the machine is being installed in a corner (Figs.
– 7 – WATER REQUIREMENTS Proper water quality can improve warewashing performance by reducing spotting, lowering chemical supply costs, improving productivity and extending equipment life.
– 8 – PLUMBING CONNECTIONS WARNING : PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY AND PLUMBING CODES. DRAIN CONNECTION The drain connection is a 1 1 / 2 " externally threaded pipe connected straight down from the bottom of the wash tank (Fig.
– 9 – GAS TANK HEAT (When Specified) Check the gas data plate attached to the dishwasher or the tag attached to the incoming gas piping for the type of gas to be used. The burner is not adjustable. The maximum flowing inlet gas pressure must not exceed the Maximum value in the table.
– 10 – VENTING REQUIREMENTS — WITH GAS TANK HEAT Hobart model AM15, AM15F or AM15T dishwashers equipped for gas tank heat are not provided with a flue collar and are not intended to have the flue directly connected to a ventilation system. However, the products of combustion must be vented to the outside air.
– 11 – RATE OF EXHAUST FLOW CALCULATIONS Based on the 1996 International Mechanical Code. The Rate of air flow required for a vent hood is calculated using the following definitions (Fig. 14): Q = Rate of Air Flow in Cubic Feet Per Minute or [ CFM ] Required for the Hood.
– 12 – ELECTRICAL CONNECTIONS WARNING : ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. WARNING : DISCONNECT THE ELECTRICAL POWER T O THE MACHINE (BOTH DISHWASHER AND BOOSTER IF APPLICABLE) AND FOLLOW LOCKOUT / TAGOUT PROCEDURES.
– 13 – Dishwasher With Electric Booster (Separately Connected) Single phase machines with an electric booster require two separate connections, one for the booster and the other for the dishwasher (including motor, controls and tank heat). For single-phase machines, all power supply connections are made to terminal blocks (Fig.
– 14 – DETERGENT, RINSE AID, SANITIZER DISPENSERS — TUBING INSTALLATION Detergent, rinse aid and / or sanitizer dispensers (not provided by Hobart) must have all connections sealed against leakage. The dishwasher uses 0.74 gallons of rinse water per rack at a flow rate of 4.
– 15 – EQUIPMENT CONNECTIONS — Detergent, Rinse Aid, Sanitizer Dispensers WARNING : ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
– 16 – SETUP (All Models) Sanitizing Mode • With the machine OFF, press the ON key. • Immediately press and hold the OFF key. The display initializes until 88 displays. Next, SET X °F °C displays. X can be H, C or P: H = Hot Water Sanitizing, Internal Booster.
– 17 – OPERA TION PREPARATION The overflow tube must be in its proper location below the strainer pan (Fig. 23). Place the strainer pan and the strainer bucket in their proper positions (Fig. 24 ). Fig. 23 An automatic detergent dispenser is recommended.
– 18 – DISHWASHING Scrape the dishes to remove large particles of food and debris. Never use steel wool on ware to be loaded into the dishmachine. Fig. 26 Arrange the dishes in a rack. Do not stack dishes one on top of another, as water must have free access to all sides of every dish.
– 19 – CLEANING T he machine must b e thoroughly cleaned at the end of each working shift or at least daily. Never use steel wool to clean warewasher surfaces. Use only products formulated to be safe on stainless steel. 1. Push the OFF button. 2 .
– 20 – DOs AND DON'Ts FOR YOUR NEW HOBART WAREWASHER DO assure proper water hardness (4 to 6 grains per gallon is recommended). DO pre-scrap dishes thoroughly. DO use only detergents recommended by your chemical professional. DO at the end of the day, thoroughly cleanse the machine, rinse and dry (leave door open).
– 21 – MAINTENANCE WARNING : DISCONNECT THE ELECTRICAL POWER T O THE MACHINE (BOTH DISHWASHER AND BOOSTER IF APPLICABLE) AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. Wash Arms Upper and lower wash and rinse arms (Figs. 28, 29) should turn freely and continue turning for a few seconds after being whirled by hand.
– 22 – TROUBLESHOOTING Manual Reset Button on Pump Motor If the pump motor becomes overheated, the thermal overload protector will cause the motor to not operate. If this occurs, contact Service. To avoid a service call, check symptoms and related possible causes.
– 23 – SYMPTOM POSSIBLE CAUSE Inadequate rinse or rinse 1. Dirty line strainer causing reduced water flow. Turn off water supply, remove water temperature too low. strainer cap, withdraw and clean screen. Reassemble. Possible EE display. 2. Low supply line pressure.
– 24 – SERVICE Contact your local Hobart-authorized service office for any repairs or adjustments needed on this equipment. If a gas orifice fitting is to be replaced, have it serviced by qualified Hobart-authorized service personnel. Long-term service contracts are available on this and other Hobart products.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hobart AM15T ML-130039 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hobart AM15T ML-130039 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hobart AM15T ML-130039 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hobart AM15T ML-130039 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hobart AM15T ML-130039, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hobart AM15T ML-130039.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hobart AM15T ML-130039. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hobart AM15T ML-130039 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.