Manuale d’uso / di manutenzione del prodotto NB5741XD del fabbricante Hitachi
Vai alla pagina of 24
• Single-phase Input 100V Class Manual No . NB5741XD • December 2003 Hitachi Industrial Equipment Systems Co., Ltd. HIT A CHI L100-M Series In ver ter Quic k Reference Guide.
1 Caution: Be sure to r ead the L100 In verter Manual and follow its Cautions and W arni ngs for the initial product installation. This Quick Refe r ence Guide is intended for r eference use by e xperienced users in servicing existing installations.
2 Contr ol Circuit T erminals Te r m i n a l Name Description Ratings and Notes P24 +24V for logic inputs 24VDC supply , 30 mA max. (Notes: Do not use for network power Do not short to terminal L) 1, 2, 3, 4, 5 Intelligent (program- mable) discrete logic inputs 27VDC ma x.
3 O Analog input, voltage 0 to 9. 6 VDC range, 10VDC nominal, 12 VDC max., input impedance 10 k Ω H +10V analog reference 10VDC nominal, 10 mA max. AL0 Relay common contact C ontact rating Max resistive load = 250V A C, 2.5A; 30VDC 3A; Max inductive load = 250V A C, 0.
4 Basic Wiring Diag ram The following wirin g diagram shows the power and motor c onnec- tions for basic operation. The optio nal signal input wiring supports external Fwd and Re v Run command, and a speed potentiometer .
5 In ver ter K eypad Operatio n • Run/Stop LED – ON when the inverter output is ON and the motor is de veloping torque, and OF F when the in verter output is OFF (Stop Mode). • Progra m/Monitor LED – ON when the in verter is ready for parameter editing (Program Mode) .
6 • Potentiometer – Allows an operator to directly set the motor speed when the potentiometer is enab led for output frequ ency control. • Potentiometer Enable LED – ON when the potentiometer is enabled for value entry . • Para meter Displ ay – A 4-digit, 7-segmen t display for parame- ters and function codes.
7 Ke ypad Navigation Map c9 1 c0 1 1 2 b 89 b 01 1 2 A9 8 A0 1 1 2 1 2 1 2 1 2 C– – 1 2 b –– 1 2 A– – F0 4 F0 1 1 2 d 09 d 01 1 2 o.0 12 3 . 4 Edit 1 2 Increment/ decrement val ue Write data to EEPROM Displa y data Monitor Mode Program Mode FUNC.
8 P owerup T est The Power up T est procedure uses minimal parameter settings to run the motor . The proced ure describes two alternati ve methods for commanding the in verter: via the in verter keypad , or via the logic termin als . • Check po wer input and motor output wiring (see page 4 diagram).
9 Err or Codes The L100 series inv erters will trip on ov er-current, over -voltage, and under-voltage to protect the in verter . The motor output turns OFF , allowing the motor to free-run to a stop. Press the Stop/Reset ke y to reset the inv erter and clear the er ror .
10 Erro r T rip Conditions Use function code D_08 to access th e error trip conditions for the current error as shown in the table below . Use the Up and Down arrow ke ys to scroll through the trip condition parameters. E35 Thermistor • Thermistor input, [THM] and [L], is over the temp.
11 Restoring Factory Default Settings Action Display Function/Parameter Press , or as needed. b -- “B” Group selected Press . b 01 First “B” Group parame- ter Press/hold until... b 85 Coun try code for initialization selected Press . If setting is correct, then skip next step.
12 Note: After initializing the inverter , us e the P owerup T est on pag e 8 to get the motor running again. Pa ra m e te r T a b le s “D” Gr oup: Monitoring Functio ns Func.
13 T rip History Na vigation Map E0 7 60 . 0 1 2 4. 0 0 27 0 . 0 1 2 1 2 d 08 1 2 o.0 0 Displa y data Monitor Mode 1 2 FUNC. FUNC. d 09 ____ No Error code Output frequency at trip point Motor current at trip point DC bus voltage at trip point FUNC. Ye s No error Error (n-1) ex is ts ? No Ye s E0 3 E0 5 ____ No history FUNC.
14 Parameter tables for user-settable functions follo w these conven- tions: • Some parameters specify an op tion code. Where applicable, the options codes will be in a bulleted list in the Name/Description column. • The default v alues apply to all models unless otherwise noted for each parameter.
15 “A” Group: Standard Functions Func. Code Name / Description Default Va l u e –FE / –FU / –FR Set Va l u e A_01 Frequency source setting • 00 Ke ypad pot entiometer • 01 Control termin.
16 A_41 T orque boost method selection • 00 Manual torque boost • 01 Automatic torque boost 00 A_42 Manual torque boost value 11 A_43 Manual torque boost frequ ency adjust- ment 10.
17 “B” Gr oup: Fine-tuning Fu nctions A_82 A VR voltage select 230/230/200 400/460/400 A_92 Acceleration (2 ) time setting 15.0 A_93 Deceleration (2 ) time setting 15.0 A_94 Select metho d to switch to Acc2/Dec2 profile • 00 2CH input from terminal • 01 transition frequency 00 A_95 Acc1 to Acc2 frequency transition point 0.
18 B_12 Lev el o f electronic ther mal setting Rated current of each in verter B_13 Electronic thermal character istic • 00 Reduced torque • 01 Const.
19 “C” Gr oup: Intelligent T erminal Functions B_88 Rest art mode after FRS • 00 Restart from 0Hz • 01 Restart from frequency detected from actual speed of motor 00 B_89 Data select for di git.
20 C_21 T erminal [11] functi on Six option codes av ailable (see page 22) 01 C_22 T erminal [12] function 00 C_23 [FM ] signal selection Three option codes av ailable (see page 22) 00 C_31 T erminal .
21 Intelligent Input T erminal Listing Symbol Code Input T erminal Name FWD 00 Forw ard Run/Stop R V 01 Re verse Run/Stop CF1 02 Multi-speed select, Bit 0 (LSB) CF2 03 Multi-speed select, Bit 1 CF3 04.
22 Intelligent Output T erminal Listing Analog Inpu t Configuration The following tables show the parameter settings required for vari- ous analog input signal types.
23 Notes:.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hitachi NB5741XD è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hitachi NB5741XD - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hitachi NB5741XD imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hitachi NB5741XD ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hitachi NB5741XD, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hitachi NB5741XD.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hitachi NB5741XD. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hitachi NB5741XD insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.