Manuale d’uso / di manutenzione del prodotto 707U del fabbricante Herrmidifier Co
Vai alla pagina of 16
Introduction ........................................1 Specifications ......................................1 Capacity Selection Guide ..................2 Operation of Humidifier ....................2 Installation Selecting a Location ................
1 Dear Owner: Congratulations on your choice of a Herrmidifier brand humidification system. Y our family can now look forward to breathing more comfortable air , winter after winter . W e are committed to providing advanced products that improve the quality of the air you breathe.
2 Capacity Selection Guide Operation Y our centrifugal atomizer type humidifier operates on the principle of breaking down water droplets into a fine mist and atomizing the moisture into the air .
3 Selecting a location for the unit Mounting on face of vertical return duct or side of horizontal return duct When mounting your humidifier on the face of a horizontal return duct, or on the face of .
4 Selecting a location for the unit Mounting behind a wall using the discharge extension (707U only) When selecting a location for the installation of your humidifier as a free standing unit, certain conditions must be met for its proper operation: Locate the humidifier in a convenient spot where the working part of the humidifier can be hidden (i.
5 Physical installation Caution: Only a trained HV AC servicer or contractor should install this humidifier . Do not connect the unit to the power source until installation is complete. A thorough checkout of the unit installation should be completed before operation.
6 Mounting on the face of a vertical return duct or side of a horizontal return 1. Mount the installation template on the side of the cold air return air duct with the center line of the template lined up with the center line of the return air duct. The narrow side of the duct may be used if space permits.
7 Mounting behind a wall using discharge extension (707U only) 1. Locate the inside wall template and mount on inside wall. The inside wall opening must be cut first. Be sure to follow the limitations noted as A, B, and C printed on the template. 2. Check the template with a level to ensure proper installation of the humidifier .
8 11. Before mounting the humidifier in its final position, carefully rotate the impeller assembly by hand to ensure it rotates freely . Mount the humidifier on the wire mounting bracket with the float and valve assembly connection facing the most convenient location, but providing the least obstruction to traffic.
9 Physical installation Final installation steps for all mounting locations • Install the saddle valve on the nearest cold water supply pipe (see the instructions on the package). If applicable, connect the saddle valve upstream of any type of water softener .
10 Electrical installation This humidifier is intended to be wired directly to the integrated control panel on your furnace. The electrical tap will provide power to the humidifier whenever the circulating air blower is in operation.
11 Humidistat: 1. Locate the humidistat in the living area (see location of humidifier diagram on page 4), making sure that it is at least five (5) feet from a supply register (duct mounted installation) or discharge nozzle (free standing installation).
12 Maintenance To enjoy the benefits of a properly humidified environment, periodic cleaning is necessary to control both water and household impurities. Film or scum, which can contain bacteria or fungi, may appear on the water surface, the sides, or bottom of your humidifier .
13 Maintenance instructions for models mounted on the face of a vertical return duct, side of a horizontal return duct, or mounted behind a wall using discharge extension Y our humidifier is constructed from quality materials to assure superior performance during normal operation.
4 2 3 1 15 16 17 5 8 9 10 11 12 13 14 7 6 14 Parts List ITEM 707U-UK 707U PART NO. DESCRIPTION 11 14 0 DISCHARGE DOME 21 1 252413-001 MOTOR COVER 34 41 9 RET AINER CLIP 41 1 352728-001 MOTOR BASE 51 1.
Wa rranty Humidifier Limited T wo Y ear W arranty This limited warranty covers Herrmidifier Residential T ype Humidifiers, excluding duct work, wiring and installation. The manufacturer warrants that all new Herrmidifier Humidifiers are free from defects in material and workmanship under normal, non-commercial use and service.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Herrmidifier Co 707U è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Herrmidifier Co 707U - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Herrmidifier Co 707U imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Herrmidifier Co 707U ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Herrmidifier Co 707U, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Herrmidifier Co 707U.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Herrmidifier Co 707U. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Herrmidifier Co 707U insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.