CSL CSM CSB 62 INTRODUCTION This section provides the installation instr uctions for the Henny Penny Electric Combi-Steamers. NOTE: The installation of this unit must conform to all local, state, and federal codes. In the absence of codes use ANSI/NFP A No.
CSL CSM CSB 63 Installation – Electric Units (continued) Floor Units: NOTE: Adequate clearance must be provided for ser vicing and for operation. Minimum clearances have to be maintained from the adjacent walls.
CSL CSM CSB 64 ELECTRICAL SUPPL Y Standard electrical supply for all Combi-Steamers is 208-240 volt, 3 phase, 50-60 Hz. NOTE: The power connections are located behind the ser vice door (see section 5-3).
CSL CSM CSB 65 WA TER SUPPLY The Combi-Steamer should only be connected to a cold water supply which meets the quality requir ements by the EPA on drinking water . Soft water must be at least 5 or 6 grains. The recommended water supply pr essure is 44 psi, but 22 to 87 psi will work.
CSG 66 INSTALLA TION GAS UNITS This section provides the installation instr uctions for the Henny Penny Gas Combi-Steamers NOTE: The installation must conform with local codes or in the absence of local codes, with ANSI Z223.1 latest edition and electrical code ANSI/NFP A No.
CSG 67 Minor unevenness of the sur face/floor can be compensated by adjusting the metal legs of the stand or the appliance. The weight of the units are as follows: CSG-10 556 lbs.
CSG 68 WA TER SUPPLY-CSG The Combi-Steamer should only be connected to a cold water supply which meets the quality requir ements by the EP A on drinking water . Soft water must be at least 5 or 6 grains. The recommended water supply pr essure is 44 psi, but 22 to 87 psi will work.
CSG 69 Installation – Gas Units (continued) ELECTRICAL SUPPL Y -CSG The gas Combi-Steamer requir es 120 volt, single phase, 60 Her tz, 15 amp, 3 wire grounded ser vice.
CSG 70 GAS SUPPL Y -CSG RIGHT MINIMUM PULL of equipment away from wall permissible for accessibility to Quick Disconnect Device WRONG A VOID SHARP BENDS AND KINKS when pulling equipment away from wall. (Maximum pull will kink ends, even if installed properly , and reduce Connector life.
CSG 71 GAS SUPPL Y (continued) A steam bur ner gas valve and dr y heat bur ner gas valve r espectively are responsible for the gas supply to the indi- vidual bur ners. The Combi-Steamer models CSG have manual shut-of f valves, that can be r eached from the front without tools.
CSG 72 NOTE: After turning on the gas, the manual shut-of f valve must remain open, except during pressure testing as outlined in the above steps, or when necessar y during service maintenance. This incoming pressur e reading can be taken by installing a gas pressur e gauge on the front of the unit’s main gas valves test por t.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Henny Penny CSM è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Henny Penny CSM - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Henny Penny CSM imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Henny Penny CSM ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Henny Penny CSM, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Henny Penny CSM.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Henny Penny CSM. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Henny Penny CSM insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.