Manuale d’uso / di manutenzione del prodotto T4800 del fabbricante Heatiator
Vai alla pagina of 28
12-01 1 34922 Rev B WARNING! Improper inst allation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assist ance or additional information, consult a qualified inst aller , service agency or the gas supplier .
34922 Rev B 2 12-01 T4800 INST ALLA TION INSTRUCTIONS CAUTION: Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. Wet insulation will produce an odor when the fireplace is used. T able of Contents Design and Installation Considerations .
12-01 3 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS DESIGN AND INST ALLA TION CONSIDERA TIONS When selecting a location for your woodburning fireplace, it is important to evaluate a number of considerations. Modern construction techniques can create conditions that may not allow your chimney to draft properly .
34922 Rev B 4 12-01 T4800 INST ALLA TION INSTRUCTIONS W ARNING! This fireplace and its component s are designed to be installed and operated as a system. Any alteration to or substitution for items in this system, unless allowed by these installation instructions, will void the Underwrit- ers Laboratories listing and may void the product warranty .
12-01 5 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS C . SY STEM COMPONENTS 1. Fireplace Component s Fireplace Dimensions Perception Glass Doors DP1348 DP1348B DP1348S Bi-Fold Glass Doors DM1348 DM13.
34922 Rev B 6 12-01 T4800 INST ALLA TION INSTRUCTIONS 2. Chimney Components The following pictures show only those chimney component s which may be safely used with this fireplace.
12-01 7 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS # g o l a t a CA B 6 0 1 1 L S" 6" ¾ 4 2 1 1 1 L S" 2 1" ¾ 0 1 8 1 1 1 L S" 8 1" ¾ 6 1 6 3 1 1 L S" 6 3".
34922 Rev B 8 12-01 T4800 INST ALLA TION INSTRUCTIONS LDS33 (3 x 3) LDS46 (4 x 6) Decorative Shroud TR1 1 Round T ermination Cap TR1 1T Round T elescoping T ermination Cap ST1 175 Square T.
12-01 9 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS Figure 4 Corner Installation W ARNING! Do not draw outside air from garage sp aces. Exhaust products of gasoline engines are hazardous.
34922 Rev B 10 12-01 T4800 INST ALLA TION INSTRUCTIONS Figure 5 - Framing the Fireplace W ARNING! Do not apply combustible finishing materials over any p art of the black face of this fireplace or a structure fire may result. The black metal fireplace front may only be covered with noncombustible materials such as ceramic tile, brick, or stone.
12-01 11 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS E. CHIMNEY REQUIREMENTS When planning your fireplace location, the chimney construction and necessary clearances must be considered. The fireplace system and chimney component s have been tested to provide flexibility in construction.
34922 Rev B 12 12-01 T4800 INST ALLA TION INSTRUCTIONS Figure 8 - Chimney Height S T N E N O P M O C Y E N M I H C F O T H G I E H r e z i l i b a t S y e n m i h C 1 1 L S4 3 / 4 " s r e c a p S.
12-01 13 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS F . INST ALLA TION OF FIREPLA CE W ARNING! Before starting, do the following: 1. W ear gloves and safety glasses for protection. 2. Keep hand tools in good condition. Sharpen cutting edges and make sure tool handles are secure.
34922 Rev B 14 12-01 T4800 INST ALLA TION INSTRUCTIONS Figure 1 1 Installing the Firestop Sp acer CAUTION: Firestop spacers must be used whenever the chimney penetrates a ceiling/floor area.
12-01 15 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS W ARNING! Maintain a minimum of 2 air clearance to all parts of the chimney system at all times! Fail- ure to maintain this 2 air clearance will cause a structure fire. CAUTION: Inner flue and outer liner sections cannot be dis- assembled once locked together .
34922 Rev B 16 12-01 T4800 INST ALLA TION INSTRUCTIONS Figure 14 - Ceiling/Attic Construction Figure 15 - Air Kit Handle Location 9 . Marking the Exit Point of the Roof Locate the point where the chimney will exit the roof by plumbing down to the center of the chimney .
12-01 17 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS NOTE: Use only a noncombustible material to fin- ish the face of the fireplace below the level of the front standof fs. A noncombustible material such as USG MICORE CV230 Mineral Fiber Board, or USG DUROCK Cement Board is recommended for this purpose.
34922 Rev B 18 12-01 T4800 INST ALLA TION INSTRUCTIONS Figure 17 - Factory Built Hearth Extension Figure 18 - Field Constructed Hearth Extension W ARNING! Hearth extensions are to be inst alled only as illustrated to prevent high temperatures from occurring on concealed combustible materials.
12-01 19 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS Figure 19 - Position the Hearth Extension 18 . Position the Hearth Extension Position and secure the hearth extension over the protective metal strips that have been placed partially under the fireplace front.
34922 Rev B 20 12-01 T4800 INST ALLA TION INSTRUCTIONS G. CONSTR UCTING A CHASE Figure 20 - Chase Constructions Figure 21 - Chase Assembly 1. Materials a. The chase is constructed using framing materials much the same as the walls in your home. A variety of materials may be used including brick, stone, veneer brick, or standard siding materials.
12-01 21 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS W ARNING! Never install a single wall slip section or smoke-pipe in a chase structure. The higher temperature of this single wall pipe may radiate sufficient heat to combustible chase materials to cause a fire.
34922 Rev B 22 12-01 T4800 INST ALLA TION INSTRUCTIONS NOTE: Save and pass this instruction manual to subsequent home owners. The informa- tion provided is intended to notify and warn them about making unsafe future modifica- tions such as the addition of shelves or the use of unauthorized parts and repairs.
12-01 23 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS Figure 25 Proper Operating Positions of Bi-Fold Doors W ARNING! Burning wet, unseasoned wood can cause ex- cessive creosote accumulation. When ignited it can cause a chimney fire that may result in a serious house fire.
34922 Rev B 24 12-01 T4800 INST ALLA TION INSTRUCTIONS CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liq- uids to start or freshen up a fire in this fire- place. Keep all such liquids well away from the fireplace.
12-01 25 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS Figure 26 - Flue Draf t Flue draft is measured as negative pressure in the chimney . The amount of negative pressure determines how strong the draft is. The draft is important because it draws the combustion air into the fireplace and pulls the smoke out of the chimney .
34922 Rev B 26 12-01 T4800 INST ALLA TION INSTRUCTIONS I. MAINTENANCE INSTRUCTIONS W ARNING! A chimney fire can permanently damage your chimney system. This damage can only be re- paired by replacing the damaged component part s. Chimney fires are not covered by the Lim- ited Warranty and Buyer Protection Plan.
12-01 27 34922 Rev B T4800 INST ALLA TION INSTRUCTIONS Index A Air Clearance 15, 17 Air Kit Handle Location 16 Ashes, Disposal of 26 Attic Insulation Shield 15 B Building Codes 2, 4 C Chase 20 Chase T.
34922 Rev B 28 12-01 HEA TILA TOR WOODBURNING FIREPLACE Limited W arranty As p art of its 20-YEAR BUYER PROTECTION PROGRAM AS P ART OF ITS 20 YEAR BUYER PROTECTION PROGRAM (PROGRAM, HEARTH TECHNOLOGIES INC.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heatiator T4800 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heatiator T4800 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heatiator T4800 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heatiator T4800 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heatiator T4800, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heatiator T4800.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heatiator T4800. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heatiator T4800 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.