Manuale d’uso / di manutenzione del prodotto TGC042C-1K-120 del fabbricante Heat Controller
Vai alla pagina of 35
T GC SERIES HIGH EFFICIENCY 13-SEER NOMINAL SIZES 3 -5 TONS P ACKAGE G AS E LECTRIC U NITS C VINTAGE ENGINEERING DESIGN GUIDE.
T ABLE OF CONTENTS Engineering Features ............................................................................... 4 Introduction ............................................................................................. 5 Selection Procedure .
MODEL NOMENCLATURE - TGC SERIES T G C Package Gas Electric Roofto p 036 Cooling Capacit y (BTUH Nominal) 036 = 36,000 042 = 42,000 048 = 48,000 060 = 60,000 C Vintage 1 Electrical Designation 1 = 208-.
ENGINEERING FEA TURES TGC Series Package Gas Electric Units 1. All models feature Copeland ® Scroll ® compressors offering maximum reliability , efficiency , and quiet operation. 2. Aluminized steel heat exchanger with in-shot burners helps eliminate corrosion.
These qualit y feature s are inc lude d in the Heat Controller P ac kage Gas Electric U nit Evaporator Coil/Filter Access • Return air filters, normally provided, are removed in this photo. T ubular Heat Exchanger • Aluminized steel (viewed from supply air side panel.
1. Determine cooling and heating requirements at design conditions. Example: T otal cooling capacity ........................43,600 BTUH Sensible cooling capacity ..................34,000 BTUH Heating capacity ................................96,000 BTUH Condenser entering air .
NOMINAL 3 TONS Model TGC036C-1K-120 TGC036C-3K-120 TGC036C-4K-120 Cooling Performance 1 Gross Cooling Capacity Btuh 37400 37400 37400 EER/SEER 2 11.7/13 11.
NOMINAL 3 .5 TONS Model TGC042C-1K-120 TGC042C-3K-120 TGC042C-4K-120 Cooling Performance 1 Gross Cooling Capacity Btuh 43000 43000 43000 EER/SEER 2 11.
NOMINAL 4 TONS Model TGC048C-1K-135 TGC048C-3K-135 TGC048C-4K-135 Cooling Performance 1 Gross Cooling Capacity Btuh 49000 49000 49000 EER/SEER 2 11.4/13.
NOMINAL 5 TONS Model TGC060C-1K-135 TGC060C-3K-135 TGC060C-4K-135 Cooling Performance 1 Gross Cooling Capacity Btuh 60000 60000 60000 EER/SEER 2 11.6/13 11.
GR OSS SYSTEM PERFORMANCE D A T A— TGC036C ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 1500 [707.9] 1200 [566.3] 900 [424.8] 1500 [707.9] 1200 [566.3] 900 [424.8] 1500 [707.9] 1200 [566.
GR OSS SYSTEM PERFORMANCE D A T A— TGC048C ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C] CFM [L/s] 1940 [915.5] 1550 [731.5] 1160 [547.4] 1940 [915.5] 1550 [731.5] 1160 [547.4] 1940 [915.5] 1550 [731.
AIRFLOW PERFORMANC E — DIRECT DRIVE DIRECT -DRIVE 208 VOLT AIRFLO W PERFORMANCE External Static Pressure—Inches W .C. [kPa] CFM [L/s] Air Delivery/RPM/Watts—208 Volts Blower Size/ Motor HP [w] #.
AIRFLOW PERFORMANCE—DIRECT DRIVE External Static Pressure—Inches W .C. [kPa] CFM [L/s] Air Delivery/RPM/Watts—230 Volts Blower Size/ Motor HP [w] # of Speeds Unit Model 120,000 [35.
AIRFLOW PERFORMANCE—DIRECT DRIVE External Static Pressure—Inches W .C. [kPa] CFM [L/s] Air Delivery/RPM/Watts—460 Volts Blower Size/ Motor HP [w] # of Speeds Unit Model Motor Speed From Factory Manufacturer Recommended Air -Flow Range (Min/Max) CFM Motor Speed High CFM 1870 [883] 1830 [864] 1790 [845] 1730 [816] 80,000 [23.
Air Flow CFM [L/s] Capacity 5 T on [17.6 kW]—13 SEER Voltage 460—3 Phase 2100 [991] 860 615 915 655 955 705 1005 760 1040 820 1090 870 1130 910 1170 950 1210 995 1250 1020 1290 1060 1335 1100 1370.
ELECTRICAL DATA MODEL TGC036C-1K-120 TGC036C-3K-120 TGC036C-4K-120 TGC042C-1K-120 TGC042C-3K-120 TGC042C-4K-120 Unit Information Unit Operating Voltage Range 187-253 187-253 414-506 187-253 187-253 414-506 Minimum Circuit Ampacity 24/24 18/18 11 30/30 21/21 11 Max.
UNIT DIMENSIONS P A CKA GE GAS ELECTRIC UNITS TGR036C-TGR060C MODELS BO T T OM VIEW UNIT DIMENSIONS 18 Heat Controller, Inc. -18-.
UNIT DIMENSIONS P A CKA GE GAS ELECTRIC UNITS UNIT DIMENSIONS 19 Heat Controller, Inc. -19-.
Accessory 3-5 T on [10.6-17.6 kW] Economizer with Single Enthalapy 70 [32] Power Exhaust 19 [9] Fresh Air Damper (Manual) 11 [5] 9 [4] 16 [7] 60 [27] Fresh Air Damper (Motorized) 13 [6] Roof Curb 14&q.
*Voltage 1 = 208/230 V AC-1PH-60HZ 4 = 460 VAC-3PH-60HZ 3 = 208/230 V AC-3PH-60HZ NOTES: ➀ If a particular unit is to be converted to operate on LP (propane) for elevations above 2000 ft.
R OOFCURBS (Full Perimeter) ■ This roofcurb design can be utilized on 3 through 5 ton models. ■ T wo available heights (14" and 24" for ALL models. ■ Quick assembly corners for simple and fast assembly . ■ Opening provided in bottom pan to match the “Thru the Curb” electrical connection opening provided on the unit base pan.
■ Features Honeywell Analog Controls ■ Field installed accessory ■ Gear Driven Direct Drive Actuator ■ Fully Modulating (0-100%) ■ Low Leakage Dampers ■ Horizontal or Downflow Applications.
Illustration ST -A0903-01 FRESH AIR D AMPER RKNA 3-5 T on [10.6-17.6 kW] Models RXRF-FBA1 (Manual) RXRF-FBB1 (Motorized) INTEGRAL PO WER EXHA UST FOR ECONOMIZER RXRX-BFF04C— 208/230V - 1 phase ■ For Honeywell economizer . ■ Downflow or horizontal applications.
DUCT AD APTERS Rectangular to Round T ransitions (Downflo w) RXMC-CB03 sizes available 18" fit all units. Drops into and secures to RXKG- Series Roofcurbs.
SIDE DISCHARGE CONCENTRIC DIFFUSER RXRN-F A60 Model No. A B C D E F G H I J K Duct Size RXRN-F A60 47 5 / 8 " [1210 mm] 23 5 / 8 " [600 mm] 11 3 / 8 " [289 mm] 21 1 / 2 " [546 mm] .
FLUSH MOUNT CONCENTRIC DIFFUSER RXRN-F A70 DIMENSIONAL D A T A ENGINEERING D A T A Model No. A B C D E F G H Duct Size RXRN-F A70 47 5 / 8 " [1210 mm] 23 5 / 8 " [600 mm] 13 1 / 2 " [343 mm] 21" [533 mm] 45" [1143 mm] 22 1 / 2 " [572 mm] 11 1 / 4 " [286 mm] 10 1 / 2 " [267 mm] 18RD Model No.
THERMOST A TS GAS/ELECTRIC RECOMMENDED THERMOST A TS WITH AND W/O ECONOMIZER Single Stage Cool w/o Economizer T w o Stage Cool w/ Economizer Maple Chase—Model #09 70 Honeyw ell—Model #T7300-A1 0 0.
WIRING SCHEMA TIC—TGC060 C -1K w/X-13 29 Heat Controller, Inc. -29-.
WIRING SCHEMA TIC—TGC036/048 C -1K w/PSC 30 Heat Controller, Inc. -30-.
WIRING SCHEMA TIC—TGC036/060 C -3K w/PSC 31 Heat Controller, Inc. -31-.
WIRING SCHEMA TIC—TGC060C-3K w/X-13 32 Heat Controller, Inc. -32-.
WIRING SCHEMA TIC—TGC060C-4K w/BELT DRIVE 33 Heat Controller, Inc. -33-.
WIRING SCHEMA TICS—TGC036/048C-4K w/PSC 34 Heat Controller, Inc. -34-.
1900 Wellworth Ave Jacks on, Michigan 49203 • Ph. 517-787-2100 • Fax 517-787-9341 THE QU ALIT Y LEADER IN CON D ITIONING AIR www.heatcontroller.com Design, material, performance data and component s subject to change without notice.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heat Controller TGC042C-1K-120 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heat Controller TGC042C-1K-120 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heat Controller TGC042C-1K-120 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heat Controller TGC042C-1K-120 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heat Controller TGC042C-1K-120, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heat Controller TGC042C-1K-120.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heat Controller TGC042C-1K-120. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heat Controller TGC042C-1K-120 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.