Manuale d’uso / di manutenzione del prodotto BHD-301-G del fabbricante Heat Controller
Vai alla pagina of 17
Heat Controller , Inc. • 1900 Wellworth A ve. • Jackson, MI 49203 • (517)787-2100 • www .heatcontroller .com SER VICE MANU AL Portable Dehumidifer Series with R-410A: BHD-301-G BHD-501-G BHD-6.
BHD-G Service Manual Portable Dehumidier with R-410A Heat Controller , Inc. 1 T ABLE OF CONTENTS 1. PREF ACE ............................................................................................ 2 1.1 SAFETY PRECAUTIONS .....................
Heat Controller , Inc. Portable Dehumidier with R-410A BHD-G Service Manual 2 1. PREF ACE This SERVICE MANUAL provides various servicing information for the unit, including the mechanical and electrical parts, etc. This dehumidier was manufactured and assembled under a strict quality control system.
BHD-G Service Manual Portable Dehumidier with R-410A Heat Controller , Inc. 3 3. Humidity Set Control The humidity level can be set within a range of 35%RH (Relative Humidity) to 85%RH (Relative Humidity) in 5% increments. For drier air , press the button and set to a lower percent value(%).
Heat Controller , Inc. Portable Dehumidier with R-410A BHD-G Service Manual 4 2. Product Installation Instructions Install the portable dehumidier in a at and spacious location where the air outlets will not be obstructed. Do not install underneath desks or inside cupboards as this will restrict the air ow .
BHD-G Service Manual Portable Dehumidier with R-410A Heat Controller , Inc. 5 3.4 OPERA TION WITH CONTINUOUS DRAINAGE On the rear of the unit, remove the rubber plug carefully . Remove the water tank rst, then push the hose onto the connector located inside of the hole.
Heat Controller , Inc. Portable Dehumidier with R-410A BHD-G Service Manual 6 4.Electronic function 4.1 POWERING ON THE UNIT When the unit is just powered on or the dropped power is just restored, the unit will immediately perform the self- diagnosis.
BHD-G Service Manual Portable Dehumidier with R-410A Heat Controller , Inc. 7 5.Basic T est Procedures 5.1 DEFECTIVE COMPRESSOR Compressors are single phase, 1 15 volt. All compressor motors are permanent split capacitor type using only a running capacitor across the start and run terminal.
Heat Controller , Inc. Portable Dehumidier with R-410A BHD-G Service Manual 8 5.2 SEALED REFRIGERA TION SYSTEM REP AIRS EQUIPMENT REQUIRED 1. V oltmeter 2. Ammeter 3. Ohmmeter 4. E.P .A. Approved Refrigerant Recovery System. 5. V acuum Pump (capable of 200 microns or less vacuum.
BHD-G Service Manual Portable Dehumidier with R-410A Heat Controller , Inc. 9 1 1. Break vacuum by charging system from the high side with the correct amount of refrigerant specied.
Heat Controller , Inc. Portable Dehumidier with R-410A BHD-G Service Manual 10 CAP ACITOR - TEST 1. Remove capacitor from unit. 2. Check for visual damage such as bulges, cracks, or leaks. 3. For dual rated, apply an ohmmeter lead to common (C) terminal and the other probe to the compressor (HERM) terminal.
BHD-G Service Manual Portable Dehumidier with R-410A Heat Controller , Inc. 1 1 6. TROUBLESHOOTING GUIDE 6.1 TROUBLESHOOTING GUIDE In general, possible trouble is classied in three kinds.
Heat Controller , Inc. Portable Dehumidier with R-410A BHD-G Service Manual 12 6.3.3 Humidity sensor check 6.3.4 Fail to start or fail to start motor.
BHD-G Service Manual Portable Dehumidier with R-410A Heat Controller , Inc. 13 6.3.5 Abnormal noise 6.3.6 Complaint and remedy Complaint Cause Remedy No display or any button failure. T ransformer (Discharge transformer before testing) Check resistance between the two input/output lines on transformer .
Heat Controller , Inc. Portable Dehumidier with R-410A BHD-G Service Manual 14 Complaint Cause Remedy Fan motor noise Fan Replace the fan if cracked, out of balance, or partially missing. Blower Replace the blower if cracked, out of balance, or partially missing.
BHD-G Service Manual Portable Dehumidier with R-410A Heat Controller , Inc. 15 7. Wiring Diagram.
04/2009 05/2010.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heat Controller BHD-301-G è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heat Controller BHD-301-G - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heat Controller BHD-301-G imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heat Controller BHD-301-G ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heat Controller BHD-301-G, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heat Controller BHD-301-G.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heat Controller BHD-301-G. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heat Controller BHD-301-G insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.