Manuale d’uso / di manutenzione del prodotto B-VMH18FC-1 del fabbricante Heat Controller
Vai alla pagina of 25
Heat Controller , Inc. • 1900 Wellworth A ve. • Jackson, MI 49203 • (517)787-2100 • www .heatcontroller .com INST ALLA TION MANU AL Indoor Models: B-VCH12FC-1 B-VCH18FC-1 B-VMH09FC-1 B-VMH12FC.
2 Installation Manual VMH SerieS Heat Controller , Inc. 1 CONTENTS SAFETY PRECAUTIONS W arning ...........................................................................................................................................2 Caution .......
3 Heat Controller , Inc. VMH SerieS Installation Manual 2 SAFETY PRECA UTIONS W ARNING R ead the follow SAFETY PRECAUTIONS carefully before installation. E lectrical work must be installed by a licensed electrician. Be sure to use the correct rating o f the power plug and main circuit for the model to be installed.
4 Installation Manual VMH SerieS Heat Controller , Inc. Outdoor Models: A - VMH18DC - 1 NOMENCLA TURE Outdoor Inverter Multi-Zone Mini-Split Heat Pump Nominal Capacity 18=18kBtu/H 27=27kBtu/H 36=36kBt.
5 Heat Controller , Inc. VMH SerieS Installation Manual 9 U nit com bination s NOTE: Th e total c apacity of indo or air handlers can not exceed the no m i nal c apacity of t he outd oor unit. The minimum qua ntity of indoor air handlers is o ne on any out door unit, whet her it is a dual, tri, or quad zone.
6 Installation Manual VMH SerieS Heat Controller , Inc. This illustration is for explanation purposes only . T h e a c t u a l s h a p e o f y o u r a i r c o n d t i o n e r m a y b e slightly different.
7 Heat Controller , Inc. VMH SerieS Installation Manual 10 7. Installat ion D etail s 7 .1 Wren ch torque sh e e t for installati on Outside dia meter T orque Additiona l tightening t orque mm in ch N . m N . m Ф6.35 1/4 15(1 53kgf .cm ) 16( 163k gf.
8 Installation Manual VMH SerieS Heat Controller , Inc. 3 Read completely , then follow step by step. Indoor unit D o n o t e x p o s e t h e i n d o o r u n i t t o h e a t o r s t e a m . Select a place where there are no obstacles i n f r o n t o r a r o u n d t h e u n i t .
9 Heat Controller , Inc. VMH SerieS Installation Manual 4 Accessories for mini-split high wall mount installation INST ALLA TION INSTRUCTIONS Note: Except for the above parts provided, any other parts needed during installation you must purchase.
10 Installation Manual VMH SerieS Heat Controller , Inc. 6 INST ALLA TION INSTRUCTIONS F i g . 4 Correct orientation of Installation Plate Wa l l Indoor Outdoor 3/16”-1/4”( 5-7mm ) F i g . 6 F i g . 5 Indoor unit installation(wall-mounted type) 2 .
11 Heat Controller , Inc. VMH SerieS Installation Manual 7 INST ALLA TION INSTRUCTIONS 1. For the left-hand and right-hand piping, remove the pipe cover from the side panel. 2. For the rear-right-hand and rear-left-hand piping, install the piping as shown in Fig.
12 Installation Manual VMH SerieS Heat Controller , Inc. 8 INST ALLA TION INSTRUCTIONS F i g . 1 2 1. Pass the piping through the hole in the wall. 2. Put the upper claw at the back of the indoor unit on the upper hook of the installation plate, move the indoor unit from side to side to see that it is securely fastened (see Fig.
13 Heat Controller , Inc. VMH SerieS Installation Manual 2 . F o u r - w a y c a s s e t t e t y p e 1. Install the main body A. The existing ceiling (to be horizontal) a. Please cut a quadrangular hole of 600¡600mm in the ceiling according to the shape of the installation paper board.
14 Installation Manual VMH SerieS Heat Controller , Inc. 1 0 INST ALLA TION INSTRUCTIONS The length could be calculated from Fig.17: Length=210+L(in general, L is half of the whole length of the installation hook) c. Please adjust the hexangular nuts on the four installation hooks evenly , to ensure the balance of the body .
15 Heat Controller , Inc. VMH SerieS Installation Manual 11 INST ALLA TION INSTRUCTIONS (2) Install the panel (3) Hang the air-in grid to the panel, then connect the lead terminator of the swing motor and that of the control box with corresponding terminators on the body respectively .
16 Installation Manual VMH SerieS Heat Controller , Inc. 2 3 Settlement of outdoor unit Anchor the outdoor unit with a b o l t a n d n u t ¦ 1 0 o r ¦ 8 t i g h t l y and horizontally on a concrete or rigid mount. F i g . 4 5 Install the outdoor unit on a rigid base to prevent increasing noise level and vibration.
17 Heat Controller , Inc. VMH SerieS Installation Manual Fit the seal into the drain elbow, the n insert the drain joint into the base pan hole of outdoor unit, rotate 90 to securely assemble them. Connecting the drain joint with an extension drain hose (Locally purchased), in case of the water draining off the outdoor unit during the heating mode.
18 Installation Manual VMH SerieS Heat Controller , Inc. D: Flaring work Firmly hold copper pipe in a die in the dimension shown in the table below . Tightening Connection • Align the center of the pipes. • Sufciently tighten the are nut with ngers, and then tighten it with a spanner and torque wrench as shown in Fig.
19 Heat Controller , Inc. VMH SerieS Installation Manual 2 6 E LE CT RI CA L WO RK F i g . 5 3 1. All wiring must comply with local and national electrical codes 2. Unit should be grounded in compliance with local and national electrical codes. 3. Wiring cable size and type must comply with all applicable local and national codes.
20 Installation Manual VMH SerieS Heat Controller , Inc. POWER L N TO A TO B L(A) L(B) N(A) N(B) S(A) S(B) O n e - t w o m o d e l s : O n e - t h r e e m o d e l s : O n e - f o u r m o d e l s : O n e - f i v e m o d e l s : F i g .
21 Heat Controller , Inc. VMH SerieS Installation Manual Air Purging Air and moisture in the refrigerant system have undesirable effects as indicated below: • Pressure in the system rises. • Operating current rises. • Cooling or heating efciency drops.
22 Installation Manual VMH SerieS Heat Controller , Inc. When Using the V acuum Pump (For method of using a manifold valve, refer to its operation manual.) 1. Completely tighten the are nuts, A, B, C, D, connect the mani - fold valve charge hose to a charge port of the low-pressure valve on the gas pipe side.
23 Heat Controller , Inc. VMH SerieS Installation Manual Perform the electric safe check after completing installation: 1. Insulated resistance The insulated resistance must be more than 2M . 2. Grounding work After f inishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester.
24 Installation Manual VMH SerieS Heat Controller , Inc. Test running Perform test operation after completing gas leak check at the flare nut connections and electrical safety check. Check that all tubing and wiring have been properly connected. Check that the gas and liquid side service valves are fully open.
25 Heat Controller , Inc. VMH SerieS Installation Manual 04/2009 10-2012.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heat Controller B-VMH18FC-1 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heat Controller B-VMH18FC-1 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heat Controller B-VMH18FC-1 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heat Controller B-VMH18FC-1 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heat Controller B-VMH18FC-1, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heat Controller B-VMH18FC-1.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heat Controller B-VMH18FC-1. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heat Controller B-VMH18FC-1 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.