1 Installation and Operation NOTICE • Important operating and maintenance instructions included.
2 .
3 • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
4 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer .
5 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor . A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation.
6 NOTICE: This fireplace is tested and approved as a decorative replace. It should not be factored as a primary heat source in residential heating calculations.
7 W ARNING! DO NOT operate replace before reading and understanding operating instructions. Failure to operate replace according to operating instructions could cause re or injury .
8 • The rst three or four res should be of moderate size to allow the oils and binders to be burned from the repla ce and the refractory and paint to cure. Y ou may notice an industrial odor the rst few res. This is considered normal.
9 FULL Y OPEN CORRECT P ARTL Y CLOSED INCORRECT P ARTL Y OPEN INCORRECT FULL Y CLOSED CORRECT .
10 Y our replace performance depends on the quality of the rewood you use. • Seasoned wood contains about 8,000 BTUs per pound. • Hard woods are more dense than soft woods.
1 1 .
12 After each ash removal Homeowner After each ash removal Homeowner Inspect grate for: • W arping or sagging 1-1/2 in.
13 .
14 Heat &.
15 Negative pressure results from the imbalance of air avail- able for the replace to operate properly . It can be stron- gest in lower levels of the house.
16 Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-level Roofs Windward Leeward Recommended Location: • Above peak R.
17 Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw Framing material Pliers Non-combustible sealant Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits Plumb line Safety glasses Level T ape measure 1/2-3/4 in.
18 Note: 1-1/2 in.
19 W ARNING! Risk of Fire! Y ou must comply with all minimum air space clearances to combustibles as specied in Fig- ure 6.
20 60 5/8 in. [1540 mm] 50 in. [1270 mm] 24 in. [610 mm] 19 3/4 in. [502 mm] 24 in. [610 mm] 22 3/8 in. [568 mm] FLUSH FRONT 4 in. [102 mm] BRICK FRONT 50° angle 39° angle Grid represents inch scale. Figure 6.
21 CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation.
22 • Place the replace on a continuous at surface. • Follow framing instructions in Section 6. W ARNING! Risk of Fire! Prevent contact with sag- ging, loose insulation.
23 • Position the bottom of the back refractory to the back of the fireplace and center from side to side. See Figure 7.1 1. Be sure to position it so the retainer notch is at the top.
24 Outlet placed higher than 3 ft below the termination cap Attic space Garage or combustible liquids storage Outlet blocked by snow , leaves, etc. Clear area outside house or in ventilated crawl spac.
25 • Locate outside air kit on one side of replace. • Open door (raise handle up to open, refer to Figure 2.1 for location of handles).
26 Chimney must extend beyond combustible roof structure Maintain minimum height of chimney above roof Additional support for tall chimneys Install roof flashing according to minimum requirements Main.
27 Measure vertical distances from the base of the replace as shown in Figure 8.2. 6 ft (1.83 m) max. unsupported run 20 ft (6.10 m) max. pipe between an offset & return Ceiling Firestop 35 ft (10.
28 • Use an offset/return to bypass overhead obstructions. • An offset and return can be used as a single entity or separated by chimney section(s).
29 • Support the pipe during construction and check to be sure inadvertent loading has not dislodged the chimney section from the replace or at any chimney joint.
30 ROOM ABOVE (non-insulated ceiling) A TTIC ABOVE (insulated ceiling) B A Ceilng firestop from bottom Ceiling firestop from top Note: Use same dimensional lumber for framing ceiling firestop and joists.
31 3 in. (76 mm) overlap Insert three screws Bend inward 90° Bend remaining tabs to rest against pipe to prevent insula tion from falling in. Installation of a ceiling restop is required • Refer to Figures 8.
32 W ARNING! Risk of Fire! Y ou MUST maintain 2 in. (51 mm) air space to insulation and other combustible materials around the chimney system.
33 Slanted Roofs Flat Roofs Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of the chimney Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.
34 Ceiling Firestop Metal Chase T op Round T ermination Cap False Ceiling Insulation in the outside walls of the chase Attic Insul.
35 Slope Downward (1/4 in. per foot minimum) T urn-down Drip Edge Chase 2 in. (51 mm) Collar on Chase T op .018 (26 ga) min. Galvanized Chase T op .
36 Heat & Glo • EXCLAIM-50 • 4013-041 • Rev AA • 7/12 Storm Collar Chimney Pipe Chase T op T ermination Cap Chase 14 1/2 in. (368 mm) Maximum Collar 2 in. (51 mm) Minimum Height Caulk gaps between storm collar & pipe, and storm collar & chase top.
37 3 in. (76 mm) tall legs Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap Length x Width to fit inside shroud • Chase top shrouds may be eld constructed where permitted by regional building codes.
38 3 in. (76 mm) Min. Opening Height Min. Base Dim Min. Height above radiation shield Min. Base Dim 3 in. (76 mm) Min. Radiation Shield Height from top of Chase Min.
39 • Materials which will not ignite and burn, composed of any combin.
40 H e a r t h e x t e n s i o n d e s i g n m u s t b e determined befo re installatio n of replac e. 20 in. Min. Hearth Extension Floor Non-combustible Framing Material Non-combustible Finishing Material Protective Metal Hearth Strips 1/2 in.
41 After completing the framing and applying the facing materials over the framing, a bead of non-combustible sealant must be used to close off any gaps at the top and sides between the replace hearth.
42 Refer to Sections 1 1.A. and Sections 1 1.B. for combus- tible/non-combustible materials. Refer to Figure 1 1.9 for non-combustible zone. W ARNING! Risk of Fire! Y ou must maintain clearances.
43 • Refer to shaded areas of Figure 1 1.1 1 for locations and dimensions of combustible mantels • A combustible mantel may be positioned no lower than 20 in. (508 mm) above the top of the replace opening.
44 • Adjacent combustible sidewalls must be located a minimum of 24 in. (610 mm) from the fireplace opening. • Combust ible or non-combusti ble mantel legs, surrounds and stub walls may be constructed per Figure 1 1.
45 Firebox Repack insulation knockout Combustible materials Maintain air clearance to combustibles. Gas line Combustible materials may be located at zero clearance to gas line beyond 4 in. (102 mm) from fireplace side. Gas line 1 1/2 in. (38 mm) air space around pipe Refractory Seal with fireplace mortar or non-combust- ible sealant 4 in.
46 60 5/8 in. (1540 mm) 20 3/4 in. (527 mm) 1 1 5/8 in. (295 mm) 29 1/2 in. (749 mm) 14 3/4 in. [375 mm] Gas Knockout 9 7/8 in.
47 20 in. (508 mm) 66 in. (1676 mm) 1/2 in. (13 mm) .
48 The following pictures show only those chimney components which may be safely used with this replace. ID4 Insulated Duct UD4 Uninsulated Duct 42 in. (1067 mm) 4 in. (102 mm) i.d. 42 in.
49 Heat & Glo • EXCLAIM-50 • 4013-041 • Rev AA • 7/12 .
50 A B C D E D A C B in. mm in. mm in. mm in. mm LDS33 36 914 36 914 8.
51 07/12 IMPORT ANT : THIS IS DA TED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number .
52 • Important operating and maintenance instructions included.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heat & Glo LifeStyle Exclaim-50 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heat & Glo LifeStyle Exclaim-50 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heat & Glo LifeStyle Exclaim-50 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heat & Glo LifeStyle Exclaim-50 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heat & Glo LifeStyle Exclaim-50, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heat & Glo LifeStyle Exclaim-50.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heat & Glo LifeStyle Exclaim-50. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heat & Glo LifeStyle Exclaim-50 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.