Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 1 Owner ’ s Manual Installation and Operation Models: BA Y -40, PIER-40 Multi-sided Woodburning Fireplace DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 2 Read this manual before installing or operating this fi replace. Please retain this owner ’ s manual for future reference. Congratulations on selecting a Heat & Glo wood burning fi re- place.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 3 T able of Contents 1 Listing and Code Approvals 4 A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Getting Started 5 A. Design and Installation Considerations .
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 4 1 1 Listing and Code Appro vals A. Appliance Certi fi cation This fi replace system has been tested and listed in accor- dance with UL 127 standards by Underwriters Laboratories Inc.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 5 2 2 Get ting Star ted A. Design and Installation Considerations Draft is the pressure difference needed to vent fi replaces successfully . Considerations for successful draft include: • Preventing negative pressure • Location of fi replace and chimney B.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 6 Location of the fi replace and chimney will af fect performance. As shown in Figure 2.1 the chimney should: • Be installed through the warm airspace enclosed by the building envelope.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 7 C. T ypical Fireplace System The Heat & Glo fi replace system consists of the following: • Fireplace/integral g.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 8 Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw F.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 9 3 3 F raming and Clearances A. Selecting Fireplace Location Several options are available to you when choosing a loca- tion for your fi replace. This fi replace may be used as a room divider , installed along a wall, across a corner or used in an exterior chase.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 10 B. Clearances 2 in. (51 mm) min. 0 in. to level of standoffs Attic Insulation Shield Ceiling Firestop (ceiling) (roof) (attic) (ceiling) Ceiling Firestop Offset/Return with hanger straps Storm Collar Roof Flashing 1/2 in.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 11 C. Sidewalls/Surrounds Adjacent combustible side walls must be located a minimum distance from the fi replace opening as per Figure 3.3. D. Frame the Fireplace Figure 3.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 12 E. Construct the Chase A chase is a vertical boxlike structure built to enclose the fi re- place and/or its vent system. V ertical chimneys that run on the outside of a building must be installed inside a chase.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 13 A. Install the Outside Air Kit This fi replace will operate correctly only if adequate ventila- tion is provided to allow proper draft to the fi replace system. See Section 2.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 14 LIFT T O OPEN BA Y -40 PULL TO OPEN PIER-40 Figure 4.4 Locating the Outside Air Control Outlet placed higher than 3 ft below the termination cap Attic space Garage or combustible liquids storage Outlet blocked by snow , leaves, etc.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 15 B. Secure the Fireplace • Position the Fireplace This fi replace may be placed on either a combustible or noncombustible continuous fl at surface. Follow the in- structions for framing in Section 3.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 16 NOTE: • Chimney performance may vary . • Trees, buildings, roof lines and wind conditions af fect performance. • Chimney height may need adjustment if smoking or overdraft occurs.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 17 A. Chimney Requirements V ertical distances are measured from the base of the fi re- place as shown in Figure 5.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 18 B. Using Offsets/Returns T o bypass any overhead obstructions, the chimney may be offset using an of fset/return. An offset and return may be attached together or a chimney section(s) may be used between an offset and return.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 19 Note: The ceiling fi restop MUST be nai led to the bo t tom of the ceiling joist s EXCEPT when the spac e above is uninsulated and the at tic insulation shield is not being used ( see Figure 5.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 20 6 T abs bent in 90° T abs bent in to rest against pipe Attic Insulation Shield Ceiling Firestop 13 in. (330 mm) 17 in. (432 mm) diameter Insulation Insulation Pipe Pipe Figure 5.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 21 Ceiling Firestop Straps Optional Additional Support Joint Band (Optional) Figure 5.9 Secure the Chimney Fire Risk • Secure offsets with screws (not to exceed 3/4 in./19 mm in length).
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 22 Slanted Roofs Flat Roofs Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof within 10 ft (3 m) of the chimney Chimney must extend 3 ft (.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 23 Figure 6.3 Ceiling/Attic Construction Fire Risk • Must maintain 2 in.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 24 T ermination Cap Storm Collar Slope Downward T urn-down Drip Edge Chase (Chimney) 2 in. (51 mm) Collar on Chase T op Caulk .018 (26 ga) min. Galvanized Chase T op Figure 6.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 25 2 in. (51 mm) min. 4-1/2 in. (1 14 mm) max. 1-1/2 in. (38 mm) min. overlap Cap Standoff T op of Pipe Flashing Collar Figure 6.7 Installing an ST1 175 Square T ermination Cap The last section of pipe must stop between the distances given below .
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 26 A. Gas Log/Lighter Provisions A certi fi ed gas log lighter or decorative gas log set can be installed in this fi replace. • Maximum input is 100,000 BTU/hr . • Decorative gas appliance must be certi fi ed to ANSI Z21.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 27 8 8 Fin i sh in g A. Hearth Extension A hearth extension must be installed with all fi replaces to protect the combustible fl oor in front of the fi replace from both radiant heat and sparks.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 28 Metal strips 2 in. (51 mm) under the edges of the fireplace and must extend beyond the front and side openings by 2 in. (51 mm) 1 in. (25 mm) overlap Figure 8.2 Positioning the Protective Metal Hearth Strips A B C Figure 8.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 29 72 in. (1829 mm) BA Y -40 PIER-40 40-1/2 in. (1029 mm) HEARTH EXTENSION (shaded) HEARTH EXTENSION (shaded) 6 in. (152 mm) 12 in. (305 mm) from opening of fireplace 62 in.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 30 9 9 Operat ing Instruc tions A. General Information Fireplaces, as well as other woodburning appliances, have been used safely for many years. It has been our experience that most problems are caused by improper installation and operation of the fi replace.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 31 D. Flue Damper The fl ue damper must be in full open position, and is oper- ated by moving the handle up toward the top of the fi replace. Before lighting the fi re, verify this by looking up from the in- side of the fi replace.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 32 G. Grate The factory installed integral grate must be used to hold the logs from falling out of an open fi replace and to allow air to pass between the burning logs.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 33 I. Starting a Fire Check the fl ue damper to be certain it is in the full open po- sition. Place crumpled or twisted paper under the fi replace grate. Loosely arrange kindling or small pieces of wood to form a layer above the paper .
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 34 1 0 10 T roubleshooting Another appliance in home also exhausting air (furnace, fan, dryer , etc.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 35 Diagnostic Questions Possible Causes of Condition Solutions Is the damper open? • No draft Open damper . Is there enough paper/starter? • Insuf fi cient heat to ignite kindling Use more paper/starter .
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 36 Diagnostic Questions Possible Causes of Condition Solutions Do you have glass doors? • Need to slow air intake Add glass doors. What is the condition of the wood? • Extremely dry wood Mix in less seasoned wood after fi re established.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 37 A. Disposal of Ashes Ashes should be placed in a metal container with a tight- fi t- ting lid. The closed container of ashes should be placed on a noncombustible fl oor or on the ground, well away from all combustible materials, pending fi nal disposal.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 38 Fire Risk • Do not use chimney cleaners or fl ame colorants in your fi replace. Will corrode chimney . W ARNING D. Maintenance T ask List Asphyxiation Risk Fire Risk Annual inspection by qualified technician recommended.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 39 1 2 12 Re ference Materials A. Fireplace Dimensions 42" 36" 40" 7" 12" 40" 24" GAS.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 40 B. Fireplace Components GR3 Integral Grate Bi-fold Glass Doors 16 in.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 41 C. Chimney Components The following pictures show only those chimney components which may be safely used with this fi replace. 13 in. (330 mm) 14 in. (356 mm) 14 in. (356 mm) 5-1/4 in.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 42 SL1 130 Offset/Return A B 14-1/2 in. (368 mm) Ceiling Firestop AS10 Straight Attic Insulation Shield 2 in. (51 mm) 10-1/2 in. (267 mm) JB577 Chimney Joint Band 10-1/2 in.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 43 TR1 1 Round T ermination Cap TR1 1T Round T elescoping T ermination Cap ST1 175 Square T ermination Cap TCT1 175 T erra Cotta Cap 72 in. (1829 mm) 36 in. (914 mm) 2 in.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 44 CT3-Queen CT3-Bishop CT3-Pawn CT3-Knight CT3-King 21 in. (533 mm) 47-3/4 in. (1213 mm) 24 in. (610 mm) 18-1/4 in. (464 mm) 41-1/8 in. (1045 mm) 20 in. (508 mm) 16 in. (406 mm) 38-3/8 in.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 45 Woodburning T ermination Cap Shroud TS345 / 445 (T op V ent) TR342 / 344 TR442 / 444 TR342 / 344 TV TR442 / 444 TV (with TR-TVK installed) TR1 1 / 1 1T TR1 1 / 1 1T TV (with TR-TVK installed) OPEN TOP with solid sides and 3 in.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 46 D. Service Parts Service Parts Diagram Multi-Sided Woodburning Fireplace Service Parts BA Y -40 Beginning Manufacturi.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 47 Service Parts BA Y -40 Beginning Manufacturing Date: N/A Ending Manufacturing Date: 08/01/01 Service Parts List Multi-Sided Woodburning Fireplace # Description of Part Part Number Qty .
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 48 Service Parts Diagram Multi-Sided Woodburning Fireplace Service Parts PIER-40 Beginning Manufacturing Date: N/A Endin.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 49 Service Parts List Multi-Sided Woodburning Fireplace Service Parts PIER-40 Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active # Description of Part PIER-40 Qty .
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 50 This page intentionally left blank..
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 51 E. Limited W arranty W ARRANTY FOR HEA T & GLO FIREPLACES The limited warranty will not become effective until you have mailed the completed warranty card to: Hearth & Home T echnologies Inc.
Heat & Glo • Multi-Sided Woodburning Fireplace • 34977 Rev T • 1 1/07 52 Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer , please visit www .heatnglo.com. – NOTES – F .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heat & Glo LifeStyle BAY-40 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heat & Glo LifeStyle BAY-40 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heat & Glo LifeStyle BAY-40 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heat & Glo LifeStyle BAY-40 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heat & Glo LifeStyle BAY-40, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heat & Glo LifeStyle BAY-40.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heat & Glo LifeStyle BAY-40. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heat & Glo LifeStyle BAY-40 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.