Manuale d’uso / di manutenzione del prodotto 6000TV-OAK-IPI del fabbricante Heat & Glo LifeStyle
Vai alla pagina of 20
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 1 Model: 6000TV -OAK 6000TV -OAK-IPI Underwriters Laboratories Listed In the Commonwealth of Massachusetts: • installation must be performed by a licensed plumber or gas fitter; • a CO detector shall be installed in the room where the appliance is installed.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or component s MA Y BE USED .
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 3 TABLE OF CONTENTS Safety and W arning Information . ............................................... 2 Service Parts Lists . ..............................................
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 4 Part number list on following page. 6 Log Set Assembly 5 4 2 1 3 11 10 12 8 7 9 13 (NG , LP) Exploded Parts Diagram Ser.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 5 Service Parts List ITE M CO M MO N P A RTS SERI A L # PAR T N U MB E R 1B u r n e r N G , L P SRV383-338A 2 G lass Door.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 6 (NG , LP) Exploded Parts Diagram Service Parts Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ Intermittent Pilot Ignition V alve Assembly IT E M DES CRI PT I O N SERI A L # PAR T N O.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 7 (NG , LP) Exploded Parts Diagram Service Parts 6000TV -OAK Beginning Manufacturing Date: 4-01 Ending Manufacturing Date.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 8 Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 9 2 Getting St arted Introducing the Heat & Glo Gas Fireplaces Heat & Glo B-type vent gas fireplaces are designed to op- erate with all exhaust gases expelled to the outside of the building.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 10 Figure 1. Diagram of the 6000TV -OAK GA S ACCESS GAS CONT ROL S RA TING P LA T ES & LABELS VE N T COLLAR S HOOD ST.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 11 3 Inst alling the Fireplace Step 1. Locating the Fireplace The diagram shows space and clearance requirements for locating a fireplace within a room.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 12 Step 3. Negative Pressure Make-up Air Negative Pressure warning : When negative pressure is present, an atmospherically vented fireplace (with a draft hood) may not function properly and it may down draft.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 13 ! ! Step 4. Inst alling the V ent System A. V ent System Approvals Model 6000TV -Oak is approved to use 6-inch (152mm) diameter B-type vent. B-type vent must be used when the vent system is within combustible construction.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 14 ! C. Bedroom Installation in Canada This model MUST NOT be vented into a vent system in- stalled exterior to a building. The part of the vent system above the roof line can be exterior to the building.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 15 Figure 9. Gas Supply Line • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 16 Step 9. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS TO PREVENT ACCIDENT AL FIREPLACE OPERA TION.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 17 For Intermittent Pilot Ignition (IPI) Wiring 3 V olt T ransformer This appliance comes with a 3 volt transformer . The trans- former plugs into the junction box and the two leads plug into the green control module (see Figure 12).
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 18 Step 10. Finishing Figure 13 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 19 Glass Specifications: TEMPERED Figure 16. Placement of the Ember Material Figure 15. Glass Assembly Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace.
Heat & Glo • 6000TV -OAK, 6000TV -OAK-IPI • 384-900 Rev . N • 1 1/05 20 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heat & Glo LifeStyle 6000TV-OAK-IPI è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heat & Glo LifeStyle 6000TV-OAK-IPI - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heat & Glo LifeStyle 6000TV-OAK-IPI imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heat & Glo LifeStyle 6000TV-OAK-IPI ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heat & Glo LifeStyle 6000TV-OAK-IPI, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heat & Glo LifeStyle 6000TV-OAK-IPI.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heat & Glo LifeStyle 6000TV-OAK-IPI. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heat & Glo LifeStyle 6000TV-OAK-IPI insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.