Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 1 Model: CFX-Crescent Owner ’ s Manual Installation and Operation • Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 2 ! SAFETY AND W ARNING INFORMA TION READ and UNDERST AND all instructions carefully before starting the inst allation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty .
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 3 T able of Content s Safety and W arning Information .............................. 2 Service Parts List ..................................................... 4 Section 1: Approvals and Codes .
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 4 6 4 3 5 1 2 Log Set Assembly Part number list on following page. 16 Service Parts Diagram Service Parts CFX-Crescent Beginning Manufactu.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 5 Service Parts List CFX-Crescent Regulat or NG NG K -DX F Y Regu lat or LP L PK-DX F Y A ddit ional s erv ic e par t num ber s appear on f ol lowing page.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 6 V alve Assembly Diagram/Parts List Service Parts CFX-Crescent Beginning Manufacturing Date: June 2000 Ending Manufacturing Date: ______ .
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 7 1 Approvals and Codes Approval Listings and Codes Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 8 NOTE: The following requirements reference various Massachusetts and national codes not contained in this document.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 9 2 Getting S t arted Introducing the Heat & Glo Gas Fireplaces Heat & Glo direct vent gas fireplaces are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 10 When planning a fireplace installation, it’s necessary to determine: • Where the unit is to be installed. • The vent system configuration to be used. • Gas supply piping. • Electrical wiring.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 11 3 Inst alling the Fireplace Step 1 Locating the fireplace Figure 2. Fireplace Dimensions, Locations, and Space Requirements Clearance Requirements The top, back, and sides of the fireplace are defined by stand-offs.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 12 Framing should be constructed of 2 X 4 lumber or heavier . A B C D 35 1/2” 43 5/8” 19 5/8” 47 3/4” (902mm) (1 108mm) (498mm) (1213mm) Shows center of 10” x 10” vent framing holes for top venting.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 13 Figure 4. V ent Component s and T erminations V ent System T ermination Kits V ent System Components A. V ent System Approvals This model is approved to use SL-series direct vent pipe com- ponents and terminations (as indicated in this guide), and mod- el AK-CFX air kits.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 14 Figure 5. SL-Series Direct V ent Component Specifications (4-inch inner pipe/6 5/8-inch outer pipe) Note: Pipes overlap 1 3/8 inches (34.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 15 Figure 7. Straight Up V ertical V enting STRAIGHT UP VERTICAL VENTING V (FT .) 46' MAX. (14M) The combustion air duct on the right side of the unit can run horizontally or elbow upward 46 feet long.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 16 Figure 8. V enting with eight (8) 90° Elbows Unit could have up to eight elbows off the top, with a maximum of 50 feet hori- zontal be.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 17 B . I nst alling V ent Components 1. Attach the First V ent Component to the Starting Collars T o attach the first vent component to the starting collars of the fireplace: • Apply a 3/8 inch (9.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 18 2. Continue Adding V ent Components T o continue adding vent components in accordance with the pre-planned vent system configuration: • Ensure that each succeeding vent component is securely fitted and locked into the preceding com- ponent in the vent system.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 19 For V ertical Runs - The vent system must be supported every eight (8) feet (2.4 m) above the fireplace flue outlet by wall brackets.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 20 Figure 12. 10" x 10" Hole and V ent Pipe 2. Position the firestops. 3. Place the heat shield to the top.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 21 Figure 14 . 9 ” x 9 ” Hole & New Framing Members If the area above the ceiling is NOT an attic, posi- tion and secure the ceiling firestop on the ceiling side of the previously cut and framed hole.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 22 If the area above the ceiling IS an attic, position and secure the firestop on top of the previously framed hole. NOTE: There must be NO insulation or othe r combustibles inside the framed firestop opening.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 23 Figure 17. T rapezoid T ermination Cap For trapezoidal termination: 1. Screw the cap to the exterior wall through the flanges in the cap. 2. Seal the joint between the pipe and the exterior firestop.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 24 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 18. V ent T ermination Minimum Clearances A = 12 " ....................... clearances above grade, veran- da, porch, deck or balcony B = 12 " .
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 25 For V ertical T erminations - T o locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 26 Roof Pitch H (min.) ft. flat to 6/12 1. 0 over 6/12 to 7/12 1.25 over 7/12 to 8/12 1. 5 over 8/12 to 9/12 2. 0 over 9/12 to 10/12 2. 5 over 10/12 to 1 1/12 3.25 over 1 1/12 to 12/12 4.0 over 12/12 to 14/12 5.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 27 Figure 21. Proper Positioning, Leveling, and Securing of a Fireplace Step 5 The Gas Control System W ARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL. Intermittent Pilot Ignition (IPI) System Figure 22.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 28 NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer ap- proved and/or licensed as required by the locality . (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 29 Step 7 Gas Pressure Requirement s Pressure requirements for Heat & Glo gas fireplaces are shown in the table below . Pressure Natural Gas Propane Minimum 5.0 inches 1 1.0 inches Inlet Pressure w .
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 30 CAUTION Optional Accessories Optional remote control kits require that 1 10-120 V AC be wired to the fireplace junction box. W all Switch A wall switch is provided and is required. Position the wall switch in the desired position on the wall.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 31 Figure 25. Intellifire (WSK-ML T) Wiring Diagram DO N OT USE BA TTERIES (BLACK) (R ED) (RED ) (BLA CK) DO N OT USE G Y R (RE D) (BL ACK.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 32 3” 9” 10” 12” 4” 5” 6” 7” 8” 11” NON-COMBUSTIBLE MA TERIAL FLOOR 4.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 33 Inst alling the T rim Combustible materials may be brought up to the specified clearances on the side and the top front edges of the fireplace, but MUST NEVER overlap onto the front face.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 34 Figure 29. Placement of Ember Material Positioning the Logs The logs have been p ackaged separately , refer to the installation instructions that accompany the logs. Save the log instructions with this manual.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 35 Before lighting the fireplace, be sure to do the following: • Remove all paperwork from underneath the fireplace. Review safety warnings and cautions • Read the Safety and W arning Information section at the beginning of this Installers Guide .
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 36 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and maintenance w.
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 37 Figure 30. Burner Flame Patterns MAKE SURE THE FLAMES ARE STEADY—NOT LIFTING OR FLOA TING .
Heat & Glo • CFX-CRESCENT • 705-900 Rev . P • 12/07 38 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .heatnglo.com Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heat & Glo Gas Fireplace CFX-Crescent è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heat & Glo Gas Fireplace CFX-Crescent - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heat & Glo Gas Fireplace CFX-Crescent imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heat & Glo Gas Fireplace CFX-Crescent ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heat & Glo Gas Fireplace CFX-Crescent, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heat & Glo Gas Fireplace CFX-Crescent.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heat & Glo Gas Fireplace CFX-Crescent. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heat & Glo Gas Fireplace CFX-Crescent insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.