08/04 26023 Rev L 1 INST ALLA TION & OPERA TING INSTRUCTIONS RSW -41 RSW -47 WOODBURNING FIREPLACE WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
2 26023 Rev L 08/04 RSW-41 AND RSW -47 SERIES INST ALLA TION INSTRUCTIONS CAUTION: Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. W et insula- tion will produce an odor when the fireplace is used.
08/04 26023 Rev L 3 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS DESIGN AND INST ALLA TION CONSIDERA TIONS When selecting a location for your woodburning fireplace, it is important to evaluate a number of considerations. Modern construction techniques can create conditions that may not allow your chimney to draft properly .
4 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS W ARNING! This fireplace and its component s are designed to be inst alled and operated as a system.
08/04 26023 Rev L 5 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS C. SYSTEM COMPONENTS 1. Fireplace Component s GLASS DOORS INTEGRAL GRA TE (supplied) GR25/GR26 FAN KIT DM1036/DM1042 Bifold Glass Doors JUNCTION BOX JK8 DMA1036/DMA1042 Arched Cabinet Style Glass Doors HEARTH EXTENSION BC10 Fan Speed Control FK18 CAT.
6 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS Fireplace Dimensions OUTSIDE AIR KIT AK14 Cat # A B C D RSW -41 36 i n . 41 in .
08/04 26023 Rev L 7 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS 2. Chimney Component s The following pictures show only those chimney components which may be safely used with this fireplace.
8 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS SL3 - Chimney St abilizer SL330 - Offset/Return RF370 - Roof Flashing Flat to 6/12 Pitch RF371 - Roof Flashing 6/12 to 12/12 Pitch CB876 Chimney Bracket AS8 Straight Attic Insulation Shield Chimney Sections Firestop Sp acer JB877 Joint Band Ca t a log # A B F S338 0- deg.
08/04 26023 Rev L 9 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS LDS33 (3 ft x 3 ft) LDS46 (4 ft x 6 ft) Decorative Shroud TR344 Round T ermination Cap TR342 Round T elescoping T ermination Ca.
10 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS W ARNING! Do not draw out side air from garage spaces. Exhaust products of gasoline engines are hazardous.
08/04 26023 Rev L 11 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS W ARNING! Do not apply combustible finishing materials over any part of the black face of this fireplace or a structure fire may result. The black metal fireplace front may only be covered with noncombustible materials such as ce- ramic tile, brick, or stone.
12 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS Figure 6 - Sidewalls and Surrounds 3 . Sidewalls/Surrounds Adjacent combustible side walls must be located a minimum of 12 in.
08/04 26023 Rev L 13 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS W ARNING! Do not combine offsets to create an offset greater than 30-deg from verti- cal. This may create a fire hazard since the natural draft may be restricted. 1. Using Offset s and Returns a.
14 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS Figure 8 - Chimney Height *Dimensions reflect effective height. T able 2 3. Number of Sections Required T o determine the chimney components needed to complete your particular installation, follow the step s below: a.
08/04 26023 Rev L 15 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS F . INST ALLA TION OF FIREPLACE W ARNING! Before st arting, do the following: 1. W ear gloves and safety glasses for protection. 2. Keep hand tools in good condition. Sharpen cutting edges and make sure tool handles are secure.
16 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS Figure 1 1 Installing the Firestop S pacer CAUTION: Firestop spacers must be used whenever the chimney penetrates a ceiling/floor area.
08/04 26023 Rev L 17 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS W ARNING! Maintain a minimum of 2 in. air clearance to all parts of the chimney system at all times! Fail- ure to maintain this 2 in. air clearance will cause a structure fire. CAUTION: Inner flue and outer liner sections cannot be disassembled once locked together .
18 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS Figure 14 - Ceiling/Attic Construction Figure 15 - Air Kit Handle Location 9 . Mark the Exit Point of the Roof Locate the point where the chimney will exit the roof by plumbing down to the center of the chimney .
08/04 26023 Rev L 19 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS Note: Use only a noncombustible material to finish the face of the fireplace below the level of the front standof fs. A noncombustible material such as USG MICORE CV230 Mineral Fiber Board, or USG DUROCK Cement Board is recommended for this purpose.
20 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS W ARNING! Hearth extensions are to be installed only as illustrated to prevent high temperatures from occurring on con- cealed combustible materials.
08/04 26023 Rev L 21 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS Figure 19 - Position the Hearth Extension 18. Position the Hearth Extension Position and secure the hearth extension over the protective metal strips that have been placed p artially under the fireplace front.
22 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS G . CONSTRUCTING A CHASE Figure 20 - Chase Constructions Figure 21 - Chase Assembly 1. Materials a. The chase is constructed using framing materials much the same as the walls in your home.
08/04 26023 Rev L 23 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS Figure 22 - Inst alling a TR344 Round T ermination Cap Figure 23 - Inst alling a TR342 Round T elescoping T ermination Cap 2. Chase T op Construct a chase of desired materials maintaining a minimum 2 in.
24 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS W ARNING! Never inst all a single wall slip section or smoke-pipe in a chase structure. The higher temperature of this single wall pipe may radiate sufficient heat to combustible chase materials to cause a fire.
08/04 26023 Rev L 25 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS Note: Save and pass this instruction manual to subsequent home owners. The information provided is intended to notify and warn them about making unsafe future modi- fications such as the addition of shelves or the use of unauthorized part s and repairs.
26 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS Figure 26 Proper Operating Positions of Bi-Fold Doors W ARNING! Burning wet, unseasoned wood can cause ex- cessive creosote accumulation. When ignited, it can cause a chimney fire that may result in a serious house fire.
08/04 26023 Rev L 27 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liq- uids to start or “freshen up” a fire in this fire- place. Keep all such liquids well away from the fireplace.
28 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS Figure 27 - Flue Draf t Flue draft is measured as negative pressure in the chimney . The amount of negative pressure determines how strong the draft is. The draf t is important because it draws the combustion air into the fireplace and pulls the smoke out of the chimney .
08/04 26023 Rev L 29 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS I. MAINTENANCE INSTRUCTIONS W ARNING! A chimney fire can permanently damage your chimney system. This damage can only be re- paired by replacing the damaged component part s. Chimney fires are not covered by the Lim- ited Warranty and Buyer Protection Plan.
30 26023 Rev L 08/04 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS HOMEOWNER’S NOTES.
08/04 26023 Rev L 31 RSW-41 AND RSW-47 SERIES INST ALLA TION INSTRUCTIONS INDEX A Air Clearance 17, 19 Air Kit 6, 18 Air Kit Handle Location 18 Ashes, Disposal of 29 Attic Insulation Shield 17 B Build.
32 26023 Rev L 08/04 W ARRANTY FOR HEA T -N-GLO FIREPLACES The limited warranty will not become effective until you have mailed the completed warranty card to: Hearth & Home T echnologies Inc., A DIVISION OF HON Industries 20802 Kensington Blvd., Lakeville, MN 55044.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hearth and Home Technologies RSW-41 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hearth and Home Technologies RSW-41 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hearth and Home Technologies RSW-41 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hearth and Home Technologies RSW-41 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hearth and Home Technologies RSW-41, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hearth and Home Technologies RSW-41.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hearth and Home Technologies RSW-41. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hearth and Home Technologies RSW-41 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.