Manuale d’uso / di manutenzione del prodotto COLBAY-INS del fabbricante Hearth and Home Technologies
Vai alla pagina of 37
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 1 • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 2 APPROVED FOR CANADA AND USA TO: ANSI Z21.88b-2003 / CSA 2.33b-2003 Vented Gas Fireplace Heate r , and applicab le sections o f UL307b Gas Burnin g Heating Appliances for Manufactured Homes and Recreat iona l V ehicles, CAN/C G A 2.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 3 T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Glass Speci fi cations . . . . . . . . . .
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 4 Manufactured Home or Mobile Home installation may occur only after the home is site located and must conform with the Manufactured .
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 5 A. Design and Installation Considerations Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 6 Figure 3.1 To 8 in. (203 mm ) Deep mantel: 14 in. (356 mm) From top of insert A B D C SIDE WALL HEARTH 1-1/2 in. (38 mm) 16 in. (406 mm) Model A B C D Columbia Bay Insert Inches 13 10 10 7 Millimeters 330 254 254 178 B.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 7 Fire Risk. Asphyxiation Risk. • T erminations MUST meet minimum clearances. • Exhaust gases are hot. • Nearby vents may draw fumes into house. A. V ent T ermination Minimum Clearances Figure 4.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 8 TERMINA TION CAP ADAPTER FLEX PIPE TRANSITION ASSEMBL Y SHIPPING BRACKETS A TTACHED TO REAR OF APPLIANCE FOR USE AS LEVELING LEGS A.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 9 INSULA TION V=10 FT . (3 M) MINIMUM 40 FT . (12 M) MAXIMUM TERMINA TION CAP ADAPTOR INLET AIR VENT PIPE EXHAUST AIR VENT PIPE Figure 5.3 Note: Insulation is not included with the venting kit.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 10 Kit contents: Replacement ori fi ce; replacement pilot injector; valve regulator; conversion label. T ools required: Power drill (a 90° handle is helpful); #2 Phillips bit; 5/32 in.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 1 1 A B C Figure 6.5 C. V alve Regulator Replacement Remove upper and lower back shield. Loosen the set col- lars on the extension rods with the 3/32 in. Allen wrench. Remove the rods and adapter cap.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 12 If the pressure is not suf fi cient, ensure: • The piping used is large enough. • The supply regulator is adequately adjusted. • That the total gas load for the residence does not exceed the amount supplied.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 13 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . CHECK FOR GAS LEAKS Explosion Risk Fire Risk Asphyxiation Risk • Check all fi ttings and connections.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 14 C. Standing Pilot Ignition System Wiring This appliance DOES NOT require 1 10 V AC supply for operation. A wiring diagram is shown in Figure 7.2 on the next page. This appliance is equipped with a millivolt control valve.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 15 Figure 7.2 ROCKER SWITCH / W ALL THERMOST A T / REMOTE V ARIABLE REGULA TOR PILOT ADJUSTMENT CAP MANIFOLD PRESSURE INLET PRESSURE PUSH BUTTON IGNIT OR THERMOPILE IGNITOR PILOT THERMOCOUPLE CAUTION Label all wires prior to disconnection when servicing controls.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 16 C. Door Crown Installation Open lower access panel. Pull out and unhook the two spring latches on the bottom of the appliance that secure the door. Rotate the door forward approximately 1-1/2 in.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 17 D. Grille Installation Remove the door of appliance. Remove the four screws (two at each end) holding grille in place. Lift up to remove. Figure 8.5 Determine your desired placement of the rocker switch.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 18 F . Brick Installation Figure 8.9 Figure 8.10 Figure 8.1 1 Figure 8.12 Figure 8.13 Figure 8.14 Install baffle: Bring the front edge of the baffle up and forward until the baffle rests on the baffle supports, as shown.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 19 G. Positioning the Logs While still breakable, the logs do not become fragile until after the appliance is burned and they have cured. After curing, any handling must be done with care as breakage can easily occur .
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 20 H. Mineral W ool I. Blower Installation Included in kit: Blower . T ools required: Powered Phillips head screwdriver . Figure 8.23 Figure 8.24 Figure 8.25 Explosion Risk. • Follow ember placement instructions in manual.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 21 Figure 8.26 Figure 8.27 Installation is the reverse of removal. Figure 8.28 Blower Wiring Diagram F = 1/4 in. (6 mm) female spade M = 1/4 in. (6 mm) male spade Disconnect wires from the blower.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 22 Figure 8.29 J. Air Shutter Adjustment The air shutter is used to fine-tune the flame as necessary. The air shutter is shipped in the fully open position. Allow the unit to operate 15-20 minutes before making any adjustments to the air shutter.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 23 A. Before Lighting Appliance Read this entire manual prior to using the appliance.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 24 B. Lighting Appliance 1. Set the thermostat to lowest setting. 2. T urn off all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn clockwise to "OFF" position.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 25 Initial Break-in Procedure When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 26 A. Standing Pilot Ignition System 1 0 10 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 27 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 28 A. Glass Replacement Glass can be replaced either as three separate pieces, or as an assembly with the door. See Service Parts List. T o Replace Separate Glass Pieces • Turn of f gas to the appliance.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 29 Inspect Maintenance T asks Doors 1. Inspect for scratches, dents or other damage and repair as necessary . 2. V erify no obstructions to air fl ow . 3. V erify maintenance of proper clearance to combustible household objects.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 30 MINIMUM FIREBOX OPENING Height: Width: Depth: Front Rear Front Rear T op Bottom Inches 19 13-1/2 26 20 13 13 Millimeters 483 343 6.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 31 B. V ent Components List V enting System Components Description HHT Component # LINK-DV4-30B Includes one piece 3 in. x 30 ft. Flex; one piece 3 in. x 4 ft. Flex; Cap/Adapter Linear to Coaxial with Flashing.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 32 R 2 13 14 15 6 7 8 10 12 11 9 1 3 4 5 Service Parts Diagram Columbia Bay Insert COLBA Y -INS Beginning Manufacturing Date: April 2003 Ending Manufacturing Date: ______ Service Parts Part number list on following page.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 33 COLBA Y -INS IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 34 2 13 6 7 8 10 12 11 9 1 3 4 5 Bottom Firebox Assembly R V alve Assembly Diagram Columbia Bay Insert COLBA Y -INS Beginning Manufacturing Date: April 2003 Ending Manufacturing Date: ______ Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 35 D. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and it.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 36 D. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials.
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev . H • 10/08 37 Quadra-Fire, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .quadra fi re.com E. Contact Information Please contact your Quadra-Fire dealer with any questions or concerns.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hearth and Home Technologies COLBAY-INS è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hearth and Home Technologies COLBAY-INS - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hearth and Home Technologies COLBAY-INS imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hearth and Home Technologies COLBAY-INS ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hearth and Home Technologies COLBAY-INS, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hearth and Home Technologies COLBAY-INS.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hearth and Home Technologies COLBAY-INS. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hearth and Home Technologies COLBAY-INS insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.