3-90-02702R4_08/12 www .harmanstoves.com Owner's Manual Installation and Operation Model: Super-Magnum Coal Stoker Stove NOTICE • Important operating and maintenance instructions included. • Read, understand and follow these instructions for safe installation and operation.
2 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 Hearth & Home T echnologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you have become p.
3 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 T ABLE OF CONTENTS Section 1: Listing and Code Approvals A. Appliance Certications 4 B. Mobile Home Approval 4 C. Glass Specications 4 D. Electrical Rating 4 E. BTU & Efciency Specications 4 Section 2: Special W arnings and Notes A.
4 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 1 Listing and Code Approvals A. Appliance Certication Model: Super Magnum Coal Stoker Laboratory: OMNI-T est Laboratories, Inc. Report No. 135-S-24-6.2 T ype: Solid Fuel Room Heater / Coal Burning T ype.
5 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 NEVER CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. Installation and repair of this stove should be done by a qualied service person. We recommend that the stove be inspected before use and at least annually by a qualied service person.
6 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 3 Getting Started A. Design, Installation & Location Considerations 1. Appliance Location Consideration must be given to safety , convenience, trafc ow , and the fact that the appliance will need a chimney and chimney connector .
7 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 C. Component Locations Load Door Ash Removal Door Distribution Air Filter Distribution Blower Air Grill Heat T ransfer Kit Fil.
8 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 D. Pre- Use Check List 1. Place the appliance in a location near the nal installation and follow the procedures below: 2. Open the appliance and remove all articles packed inside.
9 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 4 Dimensions & Clearances A. Appliance Dimensions.
10 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 B. Clearances T o Combustibles A C D B F E E C D B A Parallel Installation Inches Millimeters Back W all T o Unit Hopper Side.
1 1 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 5 Chimneys and V enting A. Draft Draft is widely misunderstood. It is important that you, the stove operator , realize that draft is a variable effect , not a given quantity .
12 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 D. The Chimney This unit must be installed into a chimney approved for use with solid-fuel appliances.
13 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 Do not burn any fuel other than coal. Never use highly volatile substances in your stove, such as gasoline, which could cause an explosion. When solid fuels are burned completely , they produce water and carbon dioxide.
14 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 E. Draft T est Procedure Because of the dangers associated with coal gases and the potential for carbon monoxide release, It is important to balance the airow into the stove with the draft in the ue.
15 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 6 Mobile Home A. Mobile Home Installation Mobile home approval - U.S. only . 1. An outside air inlet must be provided for combustion air , and must remain clear of leaves, debris, ice, and/or snow .
16 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 7 Appliance Set-Up A. Outside Air Attachment Parts and Supplies Needed: 1 piece of metal exible pipe, 3" X needed length. 1 Rodent Screen, Plus, you'll want to obtain a trim ring for nishing around the pipe on the inside wall.
17 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 B. Leveling the Appliance T o adjust the leveling bolts, you must rst loosen the locking nut. T urn the leveling bolt to the desired position, and re tighten the locking nut against the cast iron leg.
18 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 F . Optional Door T rim Kit The door trim kit includes a brushed stainless frame for each door , and an air grill. T o install the optional door trim, you'll rst need to remove the latch mechanism from the door .
19 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 8 Operating Instructions A. Fuel Specications The Super Magnum is designed for use with Anthracite "Rice" coal Only . Anthracite is a hard coal which is mined mostly in the Eastern United States.
20 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 Status Light Error Messages 3-Blinks: Indicates that the ESP has gone out of range too many times. Could be an indicator of build up of ash, etc. in the ue pipe or heat exchange.
21 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 a. Feed Rate Adjustment The Circuit board runs on a one minute timer cycle. Each minute, the board is thinking ahead to what it needs to do for the next minute to maintain or achieve the demanded temperature.
22 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 C. Before Y our First Fire • Be sure the appliance is installed properly and that all safety requirements have been met. Pay particular attention to the clearances to combustibles, oor protection and the venting instructions.
23 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 Symptom Possible Cause Corrective Action 9 T roubleshooting With Proper installation, operation, and maintenance, your appliance will provide years of trouble-free service.
24 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 10 Service & Maintenance A. Shut-down Procedure The best way to shut down the appliance is to simply let it run out of fuel, and shut down naturally as the temperature cools.
25 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 2. Heat Exchanger Chain Scraper • Frequency: Daily • By: User Wear Gloves T o Perform Whenever adding coal to the hopper , take the opportunity to clean the heat exchanger surfaces.
26 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 3. Fines T ray Emptying • Frequency: Weekly • By: User Wear Gloves T o Perform Fines are small dust-like particles which fall from the feed system during operation. Depending on the fuel being used, this tray may need emptied more frequently .
27 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 5. Air Filter • Frequency: Monthly • By: User Filter replacement is recommended every month. Follow the steps below to remove the lter . T urn the mode selector to "OFF" to stop the blower from operating.
Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 28 8. Chimney Connector • Frequency: As necessary / Y early • By: Qualied Service T echnician / User At the end of the burn season, brush and clean all sections of chimney connector pipe.
29 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 3. Distribution Blower Requires no lubrication. Change lter monthly to prevent build up of pet hair , etc. T o remove distribution blower; • Remove lter retainer and lter .
30 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 1 1 Reference Materials 120 V AC SUPPL Y T WISTED WIRES CONTROL THERMOST A T EXTENSION FEED MOT OR MA X. W A T TS 396 -- 3.3A. -- 120 VOL TS A.C. 60 HZ. ROOM SENSOR 6 AMP GLASS FUSE EXHAUST SENSING PROBE BOARD BLACK WHITE BLACK BLACK GREEN LABEL P ART NO.
Service Parts Super Mag Stoker Part number list on following page. 1-90-02700-1 Beginning Manufacturing Date: July 2009 Ending Manufacturing Date: Active 34 33 32 31 30 29 35 37 38 28 26 24 23 39 40 4.
Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM Description COMMENTS P ART NUMBER 43 Feeder Assembly 1-10-02700A Y 43.
Service Parts Super Mag Stoker Beginning Manufacturing Date: July 2009 Ending Manufacturing Date: Active IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer .
4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor . A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation.
38 Super-Magnum Coal Stoker Stove Do Not Burn Wet Coal! 3-90-02702R4_08/12 Service & Maintenance Log Date Of Service Performed By Description Of Service.
39 Do Not Burn Wet Coal! Super-Magnum Coal Stoker Stove 3-90-02702R4_08/12 Service & Maintenance Log Date Of Service Performed By Description Of Service.
Proudly P rinted On 100% R ecycled P aper At Harman, we build each pr oduct to a standard, not a price . (Signatur e of Box er) Y our premium quality hearth pr oduct designed and assembled by the experienced and skilled members at Harman in Halifax, P A, USA.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Harman Stove Company Super Magnum Coal Stoker Stove è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Harman Stove Company Super Magnum Coal Stoker Stove - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Harman Stove Company Super Magnum Coal Stoker Stove imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Harman Stove Company Super Magnum Coal Stoker Stove ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Harman Stove Company Super Magnum Coal Stoker Stove, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Harman Stove Company Super Magnum Coal Stoker Stove.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Harman Stove Company Super Magnum Coal Stoker Stove. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Harman Stove Company Super Magnum Coal Stoker Stove insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.