Manuale d’uso / di manutenzione del prodotto HSU-16CW03/R1 del fabbricante Haier
Vai alla pagina of 20
AS182A TNDA AU182AFNBA (HSU-18CW03/R1) AS162A TNCA AU162AFNAA (HSU-16CW03/R1) AS072AZBDA AU072ABBAA (HSU-07HW03/R1) AS072AZNDA AU072ABNAA (HSU-07CW03/R1).
Contents Cautions Parts and functions Operation Maintenance T rouble shooting 1-2 3-6 7-14 15-17 18.
Cautions Disposal of the old air conditioner Before dispos ing an o ld air condit ioner that goes out of use, please make sure it's inoperative and safe.
Cautions Always remember to unplug the air conditioner before opening inlet grill. N e v e r u n p lu g y o u r a i r c o n d i t i o n e r b y pulling on the power cord. Always grip plug firmly and pull straight out from the outlet. All electrical repairs must be carried out by qualified electricians.
P ar ts and Functions Indoor Unit AS182A TNDA AU182AFNBA (HSU-18CW03/R1) AS162A TNCA AU162AFNAA (HSU-16CW03/R1) AS072AZBDA AU072ABBAA (HSU-07HW03/R1) AS072AZNDA AU072ABNAA (HSU-07CW03/R1) Power Operation mode indicator Lights up when Timer operation is selected.
AU182AFNBA (HSU-18CW03/R1) AU162AFNAA (HSU-16CW03/R1) AU072ABBAA (HSU-07HW03/R1) AU072ABNAA (HSU-07CW03/R1) For models: For models: 14 Power Failure Resume (to be applied for a necessary situation): S.
O N O F F TEMP SWING MODE CLOCK SLEEP SET LOCK RESET TIMER FAN OFF ON AUTO AM PM AM PM AM PM P ar ts and Functions Buttons and display of the remote Power TEMP.
O N O F F TEMP SWING MODE CLOCK SLEEP SET LOCK RESET TIMER FAN OFF ON AUTO AM PM AM PM AM PM P ar ts and Functions Buttons and display of the remote Operation Hints AUT AUT DR AUT FAN Clock TEMP FAN H.
.
Unit will run in selected mode. Stop display at " " AUTO or " " FAN. Oper a tion Enjoy yourself by just a gentle press. (1) Unit start (2) Select operation mode (3) FAN (4) Unit stop AUT AUT AUT DR HEA FA Press ON/OFF button, unit starts.
Oper a tion AUT DR HEA FA COOL AUT AUT LO MED HI (1) Unit start (2) Select operation mode (3) Select temp.setting Press MODE button. For each press, operation Unit will run in operation mode displayed on LCD. Press FAN button. For each press, fan speed changes Hints (4) Fan speed selection Unit will start running to reach the temp.
After operation mode is selected, vertical flap will open automatically according to the mode. Referring to the Fig. Oper a tion When humidity is high, condensate water might occur at air outlet if all horizontal louvers are adjusted to left or right.
Oper a tion TIMER operation Hints Set Clock correctly before starting Timer operation(referring to page 6) You can let unit start or stop automatically at following times: Before you wake up in the TIMER ON/OFF (2)TIMER mode selection Press TIMER button to change TIMER mode.
Oper a tion TIMER ON-OFF (1)After unit start, select your desired operation mode Operation mode will be displayed on LCD. Power indicator on indoor unit lights up. (2) Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Select TIMER ON-OFF.
Oper a tion Emergency Carry out this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, a " Pi " sound starts once, which means the start of this operation.
Oper a tion In COOL mode In HEAT mode Approx. 6 Temp. Unit stop Temp. Unit stop Approx. 3 Note: In AUTO mode, unit will run in SLEEP function according to operation mode.
Maintenance Cut off power supply before cleaning wipe unit casing with soft cloth. In case of heavy stain, clean it with neutral detergent. squeeze water in the cloth, wipe off the detergent on unit Cleaning of unit casing Cleaning of remote controller Cleaning of air filter Don't use water to wash unit casing, please use dry cloth.
Maintenance.
Maintenance Proper room Closing of doors and windows during operation. Effective use of the Never fail to observe the Do not block the inlet or outlet. Do not use for other Do not pull power plug. Once every Avoid time- wasteful Better use of air conditioner Cleaning of the air filter.
T r ouble Shooting Before asking for service, check the following first. Cause or check Normal Performanc e Smells are Mist or steam are blown Multiple check Is power plug inserted? Is there a pow.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Haier HSU-16CW03/R1 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Haier HSU-16CW03/R1 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Haier HSU-16CW03/R1 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Haier HSU-16CW03/R1 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Haier HSU-16CW03/R1, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Haier HSU-16CW03/R1.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Haier HSU-16CW03/R1. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Haier HSU-16CW03/R1 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.