Operation & Installation Manual CONVERTIBLE TYPE AIR CONDITIONER Please read this operation manual before using the air conditioner . Please keep this manual carefully and safely .
Contents Cautions ............................................................................... Safety Precautions .................................................................. Name of Parts .....................................................
1 Cautions For the purpose of safety , the air conditioner must be properly grounded in accordance with specifications. Always remember to unplug the air conditioner before opening inlet grill. Always grip plug firmly and pull straight out from the outlet.
Cautions T emperature and Humidity Range If the air conditioner is used under higher temperature condition than those listed, the built-in protection circuit may operate to prevent internal circuit damage.
Safety Pr ecautions W ARNING! If the power supply cord of this air conditioner is damaged, it must be replaced by the manufacturer or its authorized service personnel only . Use copper wire only. All the cables shall have got the Local authentication certificate.
4 Name of Parts Fig.1 Indoor Unit 1 4 6 7 3 Fig.2 POWER OPER TIMER COMP EMER 2 3 9 8 Fig.1 1 1 10 Note : For the wired control type unit, the unit state should be checked by the the wired controller , instead of the remote receiver; and if you set the TIMER function, the TIMER LED on the remote receiver will not be on.
Cleaning and Car e CAUTION! Before cleaning the air conditioner ,be sure to turn it off and disconnect the Power Supply Cord. Be sure the Intake Grill is installed securely . When removing and replacing the air filters, be sure not to touch the heat exchanger , as personal injury may result.
Operation and Performance *Heating Performance *Microcomputer-contr olled Automatic Defr osting Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the room is heated.
Installation W ARNING ! CAUTION ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air -conditioner .
8 Installation Pr ocedures Under ceiling Outdoor unit Indoor unit 2 cm or more Ceiling Indoor unit 30 cm or more Left Right 1.5m Floor console 30 cm or more 30 cm or more 1.5m 1.5m Left Right may be difference SELECTING THE MOUNTING POSITION (1)Do not install where there is the danger of com- bustible gas leakage.
Installation Pr ocedures Open the intake grill and remove the three or four or six screws.(Fig. 1) Remark: The main unit can be wired before the indoor unit is installed. Select the most appropriate installation order . A. FLOOR CONSOLE TYPE 1. DRILLING FOR PIPING Select piping and drain directions.
Installation Pr ocedures Select whether the drain hose will be connected to the left or right side.(Fig.3) Insert the drain hose into the drain pan, then secure the drain hose with a nylon fastener . (Fig.6) 2. INST ALLING DRAIN HOSE (Fig. 6) W rap the insulation (drain hose) around the drain hose connection.
Fig. 15 3. INST ALLING BRACKETS Install the brackets with nuts, washers and spring washers.(Fig. 15) Spring washer Special nut Bracket 4. INST ALLING INDOOR UNIT Bracket (Right) Bracket (Left) Installation Pr ocedures Select piping and drain directions.
12 Installation Pr ocedures Select whether the drain hose will be connected to the left or right side.(Fig.3) Insert the drain hose into the drain pan, then secure the drain hose with a nylon fastener .(Fig.6) W rap the insulation (drain hose)around the drain hose connection.
Installation Pr ocedures HOW TO CONNECT WIRING T O THE TERMINALS A. For solid core wiring (or F-cable)(Fig.24A) (1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 25mm of the exposed solid wire. (2) Using a screwdriver , remove the terminal screw(s) on the terminal board.
14 Installation Pr ocedures ELECTRICAL REQUIREMENT Electric wire size and fuse capacity: T able 5 ELECTRICAL WIRING 1. INDOOR UNIT SIDE (1) Remove the electric component box. (2) Pull out the electric component box. Fig.28 (3) Remove the electric component box cover .
Installation Pr ocedures ELECTRICAL WIRING (1) The power sour ce capacity must be the sum of the room air conditioner curr ent and the current of other electrical appliances. When the current contracted capacity is insufficient, change the contracted capacity .
Installation Pr ocedures (2) Insert the hinges on the bottom of the intake grill into the holes in the base assembly . Then mount the arms to the three areas on the top of the intake grill. Fig. 35 Fig. 34 (1) Cut the right side of the intake grill. This is only when the pipe exits from the right side 3.
Followings are not problems Sound of water flowing is not a problem. Sound of cracking is heard. Smell are generated. During operation, white fog or steam comes out from the indoor unit. No outlet air or fan speed can't be changed in dry mode. In cooling operation, unit switches to blowing operation.
Before ask for services, please first check your unit against the following. Air conditioner won't start. Poor cooling or heating Is power supply switch turned on? Power supply switch is not set at ON.
19 T r ouble Shooting Error display ( For *.ERA ) Resumable if lower than 100 degree For remote type, flash times 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 20 21 Failure description Indoor ambient temp. sensor failure Indoor coil temp. sensor failure Outdoor ambient temp.
Resumable if lower than 100 degree Error display ( For *.EAA ) T r ouble Shooting 20 For remote type, flash times 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 20 Failure description Indoor ambient temp. sensor failure Indoor coil temp. sensor failure Outdoor ambient temp.
HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266500, P .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Haier AC182ACERA è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Haier AC182ACERA - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Haier AC182ACERA imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Haier AC182ACERA ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Haier AC182ACERA, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Haier AC182ACERA.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Haier AC182ACERA. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Haier AC182ACERA insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.