ADG / ML G-170DR Installa tion Manual Phase 7 / Non-Coin / DSI / Dual Timer / Fire Suppression System ADC Part No. 1 13409 - 2 A VERTISSEMENT : Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
“IMPORT ANT NO TE T O PURCHASER” Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas.
IMPORT ANT Y ou must disconnect and lockout the electric supply and the gas supply or the steam supply before any covers or guards are removed from the machine to allow access for cleaning, adjusting, installation, or testing of any equipment per Occupational Safety and Health Administration (OSHA) standards.
4 American Dryer Corp. 1 13409 - 2 SECTION I SAFETY PRECAUTIONS W ARNING: For your safety , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury , or loss of life.
1 13409 - 2 w ww .amdry .com 5 W ARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber , or similarly textured rubberlike materials.
6 American Dryer Corp. 1 13409 - 2 SECTION II SPECIFICA TIONS Shaded areas are stated in metric equivalents 03/25/05 IMPOR T ANT : Gas dryers must be provided with a clean, dry , and regulated 80 psi ± 10 psi (5.51 bar ± 0.68 bar) air supply . NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.
1 13409 - 2 w ww .amdry .com 7 NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. S pecifications – Gas.
8 American Dryer Corp. 1 13409 - 2 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National S tandards: ANSI Z223.
1 13409 - 2 w ww .amdry .com 9 IMPOR T ANT : The dryer must be installed in a location/environment, which the ambient temperature remains between 40° F (4.44° C) and 130° F (54.44° C) . B. UNP ACKING/SETTING UP Remove protective shipping material (i.
10 American Dryer Corp. 1 13409 - 2 2. If more headroom is needed when moving the dryer into position, the top console (module) may be removed. a . T o Remove T op Console (module)... 1) Disconnect the ground wire (A in the illustration below ) located at the rear upper left corner of the dryer .
1 13409 - 2 w ww .amdry .com 11 C. DR YER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible material. NOTE: Allowances must be made for opening the control door . A 40-inches (101.6 cm) for optimum opening of load door .
12 American Dryer Corp. 1 13409 - 2 D. FRESH AIR SUPPL Y REQUIREMENTS When the dryer is operating, it draws in room air , heats it, passes this air through the tumbler , and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors.
1 13409 - 2 w ww .amdry .com 13 E. EXHAUST REQUIREMENTS 1. General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional.
14 American Dryer Corp. 1 13409 - 2 NOTE: As per the National Fuel Gas Code, “Exhaust ducts for T ype 2 clothes dryers shall be constructed of sheet metal or other noncombustible material. Such ducts shall be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 26 gauge (0.
1 13409 - 2 w ww .amdry .com 15 IMPOR T ANT : Exhaust back pressure measured by a manometer at each tumbler exhaust duct area must be no less than 0 and must not exceed 0.6 inches (1.48 mb) of water column (W .C.). It is suggested that the ductwork from each dryer not exceed 15 feet (4.
16 American Dryer Corp. 1 13409 - 2 NOTE: When the exhaust ductwork passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening.
1 13409 - 2 w ww .amdry .com 17 The ductwork should be smooth inside with no projections from sheet metal screws or other obstructions, which will collect lint. When adding ducts, the duct to be added should overlap the duct to which it is to be connected.
18 American Dryer Corp. 1 13409 - 2 MUL TIPLE DR YER VENTING (GAS DR MODELS) WITH 12” (30.48 CM) DIAMETER (3,700 CFM [104.77 CMM]) CONNECTIONS A T COMMON DUCT.
1 13409 - 2 w ww .amdry .com 19 F . ELECTRICAL INFORMA TION 1. Electrical Requirements ALL electrical connections must be made by a properly licensed and competent electrician . This is to ensure that the electrical installation is adequate and conforms to local and state regulations or codes.
20 American Dryer Corp. 1 13409 - 2 2. Electrical Service Specifications a . Gas Models Only Ga s EL ECT R I CAL SER VI CE S PECI FI CAT I O N S ( PER DR Y ER ) IMP O R TAN T : NO TE S : A . B. C. 208 V AC AN D 230/ 240 V A C ARE N OT T HE SAME. Wh en or derin g, specify ex act v olt age.
1 13409 - 2 w ww .amdry .com 21 3. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFP A NO.
22 American Dryer Corp. 1 13409 - 2 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that the gas plumbing installation is adequate and conforms to local and state regulations or codes.
1 13409 - 2 w ww .amdry .com 23 2. T echnical Data a . Gas Specifications Shaded areas are stated in metric equivalents * Measured at the gas valve pressure tap when the gas valve is on.
24 American Dryer Corp. 1 13409 - 2.
1 13409 - 2 w ww .amdry .com 25 H. W A TER INFORMA TION BEFORE YOU ST ART! CHECK LOCAL CODES AND PERMITS Call your local water company or the proper municipal authority for information regarding local codes.
26 American Dryer Corp. 1 13409 - 2 OPTIONAL MANUAL BYP ASS Provisions are made in the dryer ’ s fire suppression system for the installation of an optional manual bypass. The connections for the manual bypass are made at the “tee” or “three way” fitting, located in the outlet supply side of the water solenoid valve.
1 13409 - 2 w ww .amdry .com 27 1 1. Check bolts, nuts, screws, terminals, and fittings for security . 12 . Check to ensure air supply (80 psi [5.51 bar]) is connected to the dryer . 13 . Check tumbler bearing setscrews to ensure they are ALL tight. J.
28 American Dryer Corp. 1 13409 - 2 IMPOR T ANT : There is no regulator provided in an L.P . dryer . The water column (W .C.) pressure must be regulated at the source (L.P . tank) or an external regulator must be added to each dryer . 6. Make a complete operational check of ALL safety-related circuits (i.
1 13409 - 2 w ww .amdry .com 29 The L.E.D. display will read MANUAL DR YING CYCLE D, 00:00 MIN REMAIN. NOTE: The dryer can be stopped at any time by pressing the “STOP/CLEAR” key , at this time the dryer will go into a cycle pause.
30 American Dryer Corp. 1 13409 - 2 M. SHUTDOWN INSTRUCTIONS If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed: 1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker .
1 13409 - 2 w ww .amdry .com 31 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency , or gas supplier . If service is required, contact the reseller from whom the ADC equipment was purchased.
32 American Dryer Corp. 1 13409 - 2 SECTION V W ARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass.
1 13409 - 2 w ww .amdry .com 33 2. Each part must be tagged with the following information: a. Model number and serial number of the dryer from which part was removed. b. Nature of failure. (Be specific.) c . Date of dryer installation. d. Date of part failure.
34 American Dryer Corp. 1 13409 - 2 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system.
1 13409 - 2 w ww .amdry .com 35 6 MONTHS Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer ’ s internal exhaust ducting. NOTE: THE ACCUMULA TION OF LINT IN THE EXHAUST DUCTWORK CAN CREA TE A POTENTIAL FIRE HAZARD .
36 American Dryer Corp. 1 13409 - 2 SECTION VII MANUAL RESET BURNER HI-LIMIT INSTRUCTIONS A. PHASE 7 This dryer was manufactured with a manual reset burner hi-limit thermostat, which is monitored by the Phase 7 computer .
1 13409 - 2 w ww .amdry .com 37 SECTION VIII DA T A LABEL INFORMA TION When contacting ADC, certain information is required to ensure proper service/parts information from ADC . This information is on the dryer data label that is affixed to the right electrical control panel.
38 American Dryer Corp. 1 13409 - 2 SECTION IX PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a . Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer .
1 13409 - 2 w ww .amdry .com 39 2. For Models with Direct Spark Ignition (DSI) Module (T ype I) Theory of Operation: Start the drying cycle. When the gas burner ignites within the chosen trial for ign.
ADC Part No. 1 13409 2 - 06/12/08 - 1.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il American Dryer Corp. ADG / MLG-170DR è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del American Dryer Corp. ADG / MLG-170DR - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso American Dryer Corp. ADG / MLG-170DR imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul American Dryer Corp. ADG / MLG-170DR ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il American Dryer Corp. ADG / MLG-170DR, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del American Dryer Corp. ADG / MLG-170DR.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il American Dryer Corp. ADG / MLG-170DR. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo American Dryer Corp. ADG / MLG-170DR insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.