Manuale d’uso / di manutenzione del prodotto G0471 del fabbricante Grizzly
Vai alla pagina of 32
COPYRIGHT © JULY, 2005 BY GRIZZLY INDUSTRIAL, INC. WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC.
.
Table of Contents INTRODUCTION ..................................................................................... 2 Foreword ........................................................................................... 2 Machine Data ................
Model G0471 3 HP Air Compressor - 2 - INTR ODUCTION If you have any comments regarding this manual, please write to us at the following address: Grizzly Industrial, Inc. C/O Technical Documentation P.O. Box 2069 Bellingham, WA 98227-2069 Most importantly, we stand behind our tools.
Model G0471 3 HP Air Compressor - 3 - SE CTION 1 : S A FET Y Indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury. It may also be used to alert against unsafe practices. Indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
Model G0471 3 HP Air Compressor - 4 - 7. KEEP CHILDREN AND VISITORS AWAY. Keep all children and visitors a safe distance from the work area. 8. MAKE WORKSHOP CHILD PROOF. Use padlocks, master switches, and remove start switch keys. Shut off air supply before leaving shop.
Model G0471 3 HP Air Compressor - 5 - A ddi tiona l Safet y Instr ucti ons fo r Air Compress ors No lis t o f safe ty gui deli nes ca n be com ple te. Ever y e nviro nme nt i s di f- fe ren t. A lways co nsid er s afe ty f irst , as i t a pp lies to your i ndiv idua l work- ing c ondi tio ns.
Model G0471 3 HP Air Compressor - 6 - SE CTION 2 : CIRC UIT RE QUIREMENTS Figure 1. Typical NEMA 6-20 plug and receptacle. Se riou s pe rson al in jur y coul d occ ur if you c onn ect th e m achi ne to t he powe r sou rce b efo re you have c om - pl ete d the s et up p roc ess .
Model G0471 3 HP Air Compressor - 7 - Ext ens io n Cord s We do not rec omm end the use of ex ten - sio n co rds on 220V e qui pmen t. In stead, arr ange t he pl acem ent of yo ur equ ipme nt and the insta lled wiring to e limi nate t he nee d fo r ex tens ion cor ds.
Model G0471 3 HP Air Compressor - 8 - Unpa cki ng SE CTION 3 : SET UP Y our air co mpre sso r lef t our war ehou se in a care full y p acked c rate or box. I f yo u dis - cover the a ir co mpre ssor is da mage d af ter you have sig ned for delive ry, plea se imme - di ately cal l Custo mer Servi ce at (570) 546 - 96 63 for advic e.
Model G0471 3 HP Air Compressor - 9 - Figure 2. Model G0471 inventory. B C D A Af ter yo u have unp acked t he c ar ton you sho uld fin d th e fo llowi ng. Mo del G 0471 Inve ntor y (F igur e 2 ) A. Compressor. ........................................
Model G0471 3 HP Air Compressor - 10 - Figure 6. Proper oil level. 6. Remove the oil breather (inset in Figure 6 ) on top of the crankcase and add compressor oil, or ISO 100/SAE 30W non-detergent oil, to the crankcase. The oil level should be in the center of the sight glass as shown in Figure 6 .
Model G0471 3 HP Air Compressor - 11 - P lacemen t Do not p lac e th e co mpr ess or nex t t o fla mma ble l iqui ds or g as ! T he co m- pr ess or motor and air sup ply pip e ca n re a ch hi gh t em pe r atu re s an d cau se t he fl amma ble gas to ignit e.
Model G0471 3 HP Air Compressor - 12 - Operation Safety SE CTION 4 : OP E RA TIONS Lon g t erm expo sur e to th is m achi ne may cau se he arin g loss . T o pr ote ct yo ur h e ar in g , a l way s we a r A NS I ap prove d ear pr otec tio n whe n ope rat- ing thi s ai r c ompr es sor.
Model G0471 3 HP Air Compressor - 13 - 6. Close the drain valve ( Figure 8 ) to allow the tank to build up pressure. 7. Check the tank pressure gauge ( Figure 9 ) to see that the tank pressure climbs to approximately 110-120 PSI (around 8 BAR) and turns OFF .
Model G0471 3 HP Air Compressor - 14 - Whe n c hoo sing air to ols, c onsi der th e amo unt of ai r u sed (c ubi c feet pe r m in- ute or CFM ) by t he to ol. N aile rs a nd sta ple gun s have a low CFM r equi reme nt bec ause they us e air i n sh or t bur sts.
Model G0471 3 HP Air Compressor - 15 - Always di scon nec t t he air ho se f rom too ls wh eneve r n ot in use or w hile se r v ic in g ! D uri ng mai nt e na nc e , a too l con nec te d to ai r may ope rat e ac ci d en ta ll y, cau si ng s e ri ous pe r - son al injur y ! Wh en s torin g you r air co mpr ess or , fo l- low the se gui del ines : 1.
Model G0471 3 HP Air Compressor - 16 - SE CTION 5 : MAINTEN ANCE Schedu le Fo r o pt im um pe r fo rm a nc e f ro m yo ur mac hine, fo llow th is main tenan ce sc hed - ule an d ref er to any sp eci fic in stru ct ions give n in th is s ec tion . Dai ly 1.
Model G0471 3 HP Air Compressor - 17 - Mon thl y Af ter the first 50 worki ng hours or 30 days, per for m t he follow ing main tenan ce: 1. Change the oil in the air compressor pump as described in Changing Oil on Page 21 . Qua rte rl y Af ter ever y 3 00 worki ng ho urs or 3 mo nths , per for m t he follow ing main tenan ce: 1.
Model G0471 3 HP Air Compressor - 18 - Main tenan ce Notes Dat e Thi s page i s for tr ack ing o il cha nge s a nd ot her mai ntena nce p roc e- dure s to en sure that th ey are per for med at the sc hedu led inter va ls.
Model G0471 3 HP Air Compressor - 19 - SE CTION 6 : SER VICE Thi s sect ion is prov ide d for your conveni enc e —i t is not a sub stit ute for the Griz zly Ser v ice Dep ar tmen t.
Model G0471 3 HP Air Compressor - 20 - Sym ptom Pos sibl e C ause Pos sibl e S olut ion Lou d re peti tio us n oise co ming fro m air co m - pres sor. 1 . Pulley sets crews or keys are mis sing or loo se. 2. Mot or f an i s hi tt ing the cover. 1 . Ins pec t keys and set- scr ews.
Model G0471 3 HP Air Compressor - 21 - Figure 15. Oil drain cap screw. 5. Replace the oil drain cap screw and remove the oil breather fill plug shown in Figure 16 . Sym ptom Pos sibl e C ause Pos sibl e S olut ion Air leaks from pressure switch. 1. Faulty check valve.
Model G0471 3 HP Air Compressor - 22 - Fi xi n g Air Leaks Air lea ks w ill caus e l ow a ir outp ut and inc reas e th e t ime the c omp ress or m ust run . To find air leaks: 1. Turn the compressor OFF when the tank is fully pressurized and unplug the compressor.
Model G0471 3 HP Air Compressor - 23 - The p ress ure swi tch ha s bee n fact or y set for the high est PSI tha t i s safe for this co mpre ssor. The pre ssur e switc h ensure s the com - pres sor w ill s hut O FF whe n the air t ank reac hes ma xim um PSI .
Model G0471 3 HP Air Compressor - 24 - Chan gi ng V - Belt Make sure the V-belt is properly tensioned. If the V-belt is too tight, the motor could overheat and cause machine damage or fire. If the V-belt is too loose, the belt will slip on the pulley and cause belt damage and compressor inefficiency.
Model G0471 3 HP Air Compressor - 25 - Ser vice Not es.
Model G0471 3 HP Air Compressor - 26 - G0 4 7 1 Parts Break do wn .
Model G0471 3 HP Air Compressor - 27 - G0 4 7 1 Parts L ist REF PART # DESCRIPTION REF PART # DESCRIPTION 1 P0471001 CRANKSHAFT 53 P0471053 SPECIAL WASHER 2 P6205 BALL BEARING 6205 54 P0471054 CONNECT 3 P0471003 CONNECTING ROD 55 P0471055 COMPRESSION NUT 4 P0471004 POSITION PIN 56 P0471056 PRESSURE GAUGE 5 PSB12M CAP SCREW M8-1.
Grizzly Industrial, Inc. warrants every product it sells for a period of 1 year to the original purchaser from the date of purchase. This warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence, accidents, repairs or alterations or lack of maintenance.
WARRANTY CARD Name _________________________________________________________________ Street _________________________________________________________________ City _______________________ State _______.
FOLD ALONG DOTTED LINE GRIZZLY INDUSTRIAL, INC. P.O. BOX 2069 BELLINGHAM, WA 98227-2069 TAPE ALONG EDGES--PLEASE DO NOT STAPLE Name________________________________ Street______________________________.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Grizzly G0471 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Grizzly G0471 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Grizzly G0471 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Grizzly G0471 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Grizzly G0471, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Grizzly G0471.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Grizzly G0471. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Grizzly G0471 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.