0910 Form # AM-328-04 Part # 63543 GRINDMASTER CORPORA TION ™ Liquid Cof fee Dispenser Operation and Instruction Manual for LCD-2A (Ambient Cabinet) & LCD-2R (Refrigerated Cabinet) © Grindmaster Corporation, 2009 Printed in USA T ABLE OF C ONTENTS Prior authorization must be obtained from Grindmaster Corporation for all warranty claims.
Page 2 Model LCD-2R and LCD-2A Introduction The Grindmaster-Cecilware Liquid Coffee Dispensers (LCD-2A) and the Liquid Coffee Chilled Dispenser (LCD-2R) deliver two types of coffee made from liquid concentrate plus hot water .
Page 3 Model LCD-2R and LCD-2A User Replaceable Part s .
Page 4 Model LCD-2R and LCD-2A W arning Labels The following warning labels were on your dispenser when it was shipped from the factory . They should remain on your dispenser in good, readable condition at all times. If one of your labels is missing or damaged, order a replace- ment label immediately .
Page 5 Model LCD-2R and LCD-2A Inst allation W ater Inlet Connection: The National Sanitation Foundation requires the following for an NSF approved water hook-up: 1. A quick disconnect water connection or enough coiled tubing so that the machine can be moved for cleaning underneath.
Page 6 Model LCD-2R and LCD-2A Inst allation (cont.) Electrical Hook-up: Ensure water connection is made to machine before proceeding and water source is turned ON. The electrical ratings for your dispenser are located on the serial plate on the outside cabinet.
Page 7 Model LCD-2R and LCD-2A 9. Af ter the water tank has completed the fill cycle, the display located on the front door of the dispenser should indicate that the heating element has been activated. Allow 10-60 minutes for the water tank to reach operating temperature.
Page 8 Model LCD-2R and LCD-2A Open the door and insert Setup key into keyswitch above cooler compartment. T urn key ¼ turn clock- wise, the display on front of door will say ‘Setup Mode, Press Enter ’.
Page 9 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Engineer Mode T o access engineer mode go into Setup mode, when the screen says ‘Setup Mode, Press Enter ’ press the Hot W ater tap – the display will now say ‘Engineer Mode, Press Enter’.
Page 10 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Engineer Mode (cont.) No prod, Stop Sel [Disabled]: No product, stop Selection. If enabled, when the cof fee goes low during a dispense it will stop, giving a low measure.
Page 11 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Machine Fault Codes (cont.) 6: W ater overheat The thermistor has detected the water is too hot. The boiler element cont actor may have failed short circuit.
Page 12 Model LCD-2R and LCD-2A T o check water flow rate and calibrate the actual mix ratio adjustment to match the programming mix ratio: “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Programming Guide for Calibration of Mix Ratio (cont.
Page 13 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Programming Guide for Calibration of Mix Ratio (cont.
Page 14 Model LCD-2R and LCD-2A W eekly Cleaning Instructions refer to Figure E NOTE: Some bag-in-box connectors require some disassembly for cleaning and sanitizing NOTE: Some bag-in-box connectors requires some extra steps for cleaning and sanitizing.
Page 15 Model LCD-2R and LCD-2A Service and Cleaning Draining the T ank Always empty the tank before shipping. 1. Prep are a minimum 5 gallon (17.5 litre) heat resistant cont ainer to drain the tank water into. 2. Unplug the machine. 3. Remove the drain tray and front access p anel.
Page 16 Model LCD-2R and LCD-2A T roubleshooting Guide A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problem encountered. If the problem remains af ter exhausting the troubleshooting steps, cont act Grindmaster- Cecilware T echnical Service Department (800-695-4500, 8am-6pm, M-F).
Page 17 Model LCD-2R and LCD-2A T roubleshooting Guide (cont.) W ARNING: Risk of electrical shock. Disconnect power before removal of any machine access p anels.
Page 18 Model LCD-2R and LCD-2A Problem/Cause Remedy LCD DISPLA Y INDICA TES “OVERFLOW” NOTE: Water must be drained from the tank below the float switch af ter the fault condition is diagnosed.
*5((1< *5< 5(' *5< 5(' %/. &RQQHFWWR/DVVKRZQIRUYROWZDWW PLQLPXP$:*FRUGDJHRU &RQQHFW.
Grindmaster® Coffee Grinders and Br ewers • PrecisionBr ew™ Brewing Systems • Espressimo® Espr esso Machines Crathco® Hot Beverage Dispensers • Crathco® Cold and Frozen Beverage Dispensers • AMW Cof fee and T ea Systems T el (502) 425-4776 • Fax (502) 425-4664 • 1-800-695-4500 (USA & Canada only) P .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Grindmaster LCD-2A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Grindmaster LCD-2A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Grindmaster LCD-2A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Grindmaster LCD-2A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Grindmaster LCD-2A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Grindmaster LCD-2A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Grindmaster LCD-2A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Grindmaster LCD-2A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.