READ AND SA VE THESE INSTRUCTIONS! Please read instructions before installing and using the HEP A Bypass Air Filtration System (HEP A system). This will help you obtain the full benefit of the HEP A sys- tem you have selected. It will also help you to avoid needless service costs.
2 T able of Contents Rules for Safe Installation and Operation ................1 Shipping and Packing List ........................................1 Specifications ..........................................................2 Introduction ..............
Media Filters Media filters strain particulates from the air . The filter media needs to have tiny holes to allow air to pass through, but not particulates. Filter types vary for all sorts of purposes. The most ef fective and proven filter media is HEP A.
4 Parts Identification 2500HV 4000HV Parts Identification 6000V Filter Section Access Panel Retaining Clips (4) 6” Intake Collar Cabinet 6” Outflow Collar On/Off Switch Motor Section Access Panel Cabinet Parts Inside Cabinet (Filter Section) Inside Cabinet (Filter Section) figure 1.
5 Parts Identification 6500, 8500 & 10000 Cabinet Parts 10”x12” Outflow Duct V ariable Speed Switch 10”x12” Intake Duct Filter Section Access Panel Motor Section Access Panel Finger T abs (4) Cabinet Inside Cabinet (Filter Section) figure 5.
6 HEP A Filter Pre-Filter - Foam HEP A Filter Mesh (Protects HEP A Filter) Inner Carbon Filter For third stage increased removal of chemicals and odors. Located inside the HEP A filter . Discard inner carbon filter when using the optional carbon canister .
7 Physical Dimensions of Unit E K K G C F B H I J A D MODEL NO. ABCD E F G H I J K Model 2500HV 15.75 14 16.25 6 6 15.75 1.75 1.25 1.5 1.5 8 (400) (356) (413) (152) (152) (400) (44) (32) (38) (38) (203) Model 4000HV 15.75 14 25 6 6 15.75 1.75 1.25 10.
8 Physical Dimensions of Unit Banvil OFF LOW MODEL NO. ABCD E F G H I J Models 6500, 8500 17.25 28 47.75 10 12 50.25 2.5 2.6 5.3 0.1 & 10000 (438) (71 1) (1213) (254) (254) (1276) (64) (66) (135) (3) Dimensions in inches (mm) figure 13.
T ypical Return to Return Application For homes with horizontal forced air handler/furnace systems. (Air handler/furnace is shown in an typical attic. See figure 7.) T ypical Return to Return Application For homes with upflow forced air handler/furnace sys- tems.
Preparation: Here are some things to consider as you decide where to install the HEP A system with an HRV/ER V . Location: • Make sure there is room to open the HEP A filter access panel for filter changes/inspections. • Keep the HEP A system in a location where you can still access the air han- dler/furnace filter .
Independent Operation: The HEP A systems can be used independently of any other equipment! The intake and outflow of the filtration system can be ducted into the same room to create a cleaner environment almost anywhere. The intake or out- flow can also be ducted elsewhere.
12 Operation Maintenance 1. Make sure that the unit is plugged into a grounded outflow (120 V olt, 60 Hz). 2. For optimum performance, the HEP A system should operate when the indoor air handler/furnace blower is on. 3. For model 2500HV & 4000HV : T urn the unit on by pressing the on/off switch to the ‘1’ position.
13 Dealer Filter Change Instructions - 2500HV , 4000HV & 6000V It is recommended that gloves and a filtered breathing mask be worn during filter replacement to avoid breathing particulates (dust, mold, pollen, etc.) captured on the filter that become airborne during the filter(s) changeout.
14 Dealer Filter Change Instructions - 6500, 8500 & 10000 It is recommended that gloves and a filtered breathing mask be worn during filter replacement to avoid breathing particulates (dust, mold, pollen, etc.) captured on the filter that become airborne during the filter(s) changeout.
1. Accessing the motor assembly a. T urn the unit off and unplug it from any electrical source before opening the cabinet. b. Remove the safety screw(s) from the motor section access panel. c. Lift the door up by the finger tabs and pull out to remove it from the unit.
16 Replacement Parts Replacement Parts for 2500HV & 4000HV (Qty .) Canadian U.S. International Complete Filter Kit - 2500HV (1 Pre-filter , 1 HEP A, 1 Carbon) 9100723709 9101723709 9101723709 Comp.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Americair 4000HV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Americair 4000HV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Americair 4000HV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Americair 4000HV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Americair 4000HV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Americair 4000HV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Americair 4000HV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Americair 4000HV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.