INSTRUCTIONS-PARTS LIST CDRACO This manual wntains IMPORTANT READ AND RETAIN FOR REFERENCE WARNINGS and INSTRUCTIONS HYDRA-CLEAN @ 251 0,3009 Pressure Washers HYDRA-CLEAN" 2510 P/N 800-901, Serie.
~A~~~~~ HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY. FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS. Read and understand all instruction manuals before operating equipment. FLUlD 1NJECTlON HAZARD General Safety This pressure washer generates very high fluid pressure.
GROUNDING INSTRUCTIONS This product must be grounded. If it should malfunction DANGER -1 or break down, grounding provides a path of least resistance for electric current to reduce the risk of Improper connection of the equipment- grounding electric shock.
HOSE SAFETY High pressure fluid in the hoses can be very dangerous. kind of wear, damage or misuse, the high pressure If the hose develops a leak, split or rupture due to any spray emitted from it can cause a fluid injection injury or other serious bodily injury or property damage.
INSTALLATION OIL DIPSTICK PUMP LEVEL Figure 1 Check for Shipping Damage Check the unit for any damage that may have occurred in shipping. Notify the carrier Immediately If there Is any damage.
Use this procedure whenever starting the pressure washer to help insure that the unit is ready to operate and starting is done safely. 1. Check the oil level. Pump: Add SAE 20 or 30 weight non-detergent oil as necessary. 2. Tum on the water supply. CAUTION Never run the unit dry.
Trigger Safety Latch WARNING To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, ALWAYS engage the trigger safety moment.
~ SHUTDOWN, FLUSHING AND STORAGE WARNING PRESSURE RELIEF PROCEDURE To reduce the risk of serious bodily injury, eyes, or on the skin, always follow this including fluid injection and splashing in the than 10 minutes, when shutting down, and procedure whenever you stop spraying for more before checking or repairing any part of the system.
TROUBLESHOOTING CHART WARNING io reduce the risk Of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, or inlury from moving parts, always follow the Pressure Rellef Procedure Warning before procaeding.
PARTS DRAWING 800-900 Hydra-Clean@ 3009 Pressure Washer 800-901 Hydra-Clean@ 25lO~Pressure Washer 10 308-535.
~ ~~~ ~~~ PARTS DRAWING 800-901 Hydra-Cleans 2510 Pressure Washer 800-900 Hydra-Cleans 3009 Pressure Washer REF NO. 2 1 3 4 5 6 7 8 9 10 11 12 14 13 15 16 17 18 19 PART NO. DESCRIPTION 800-643 CHASSIS 803-788 BELT GUARD 801-941 SCREW, Cap, hex hd., 5/16-18 x 1 100-214 WASHER; Lock, 5/16 100-023 WASHER, Flat, 5/16 801-817 MOTOR, 20 hp.
PARTS DRAWING 801-790 Pump Assem 20 13 16 4i 12 308-535.
PARTS LIST 801-790 Pump Assembly, 2500 psi REF PART NO. NO. DESCRIPTION REF PART QTY NO. NO. DESCRIPTION 1 801.-781 MANIFOLD 3 801-469 WASHER, Lock 2 801-468 SCREW, Cap, hex hd 16 ' 33 803-283 SC.
PARTS DRAWING 803-814 Pump Assem 20 41 14 308-535.
PARTS LIST 803-814 Pump . -... 801-781 MANIFOLD NO. DESCRIPTION 3 2 4 5 6 7 8 9 10 12 11 13 14 16 15 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 801-468 SCREW, Cap, hex hd ~ ~ ~~~ ~- 801-469 WASHER. Lock Kit 1 Kit 1 O-RING ~' ~ SEAT. Valve Kit 1 PLATE, valve Kit 1 SPRING.
PUMP SERVICE WARNING To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, always follow the Pressure Relief Procedure Warnlng before proceeding. 1 NOTE: The following metric wrenches are needed: Refer to the individual repair sections and the M10, Mi3 and M30.
Servicing the V-Packings NOTE: There are two types of packing kits: one is packings only, the other includes the packings, rings and retainers. 1. Remove the manifold as outlined in the Pumping Section. 2. Carefully pull the packing retainer from the manifold.
TECHNICAL DATA Motor (totally enclosed fan cooled) Electrical Se~i~e Water Pump Maximum Working Pressure Water Pumo Maximum Flow Dimensions Width Length Height Maximum Inlet Water Temperature wetted p.
THE GRACO WARRANTY WARRANTY AND DISCLAIMERS and workmanship on the date of sale by an authorized Graw distributor to the original purchaSErfor Use. Graoawarmntsallequipmentmanufactursdby~andbearingits.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco Hydra-Clean 2510 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco Hydra-Clean 2510 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco Hydra-Clean 2510 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco Hydra-Clean 2510 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco Hydra-Clean 2510, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco Hydra-Clean 2510.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco Hydra-Clean 2510. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco Hydra-Clean 2510 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.