Manuale d’uso / di manutenzione del prodotto 824004 del fabbricante Graco
Vai alla pagina of 16
308645 Rev . D INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Contractor FTx Airless Spray Gun 3600 psi (252 bar) MAXIMUM W.
2 308645 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation/Operation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . System Requirements 5 . . . . . . . . . . . . . . . . . .
308645 3 W ARNING INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
4 308645 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately .
308645 5 Installation/Operation System Requirements W ARNING Keep the wallet-sized warning card provided with this gun with the operator at all times. The card contains important treatment information should an injection injury occur . Additional cards are available at no charge from Graco Inc.
6 308645 Installation/Operation How to Use the Gun 1. Connect a grounded fluid hose to the gun inlet. See Fig. 2 2. With no tip installed, start the pump. Flush the pump according to the instructions supplied with it. Prime the system with the fluid. 3.
308645 7 Installation/Operation How to Clean the Spray Tip and Clear a Spray Tip Obstruction W ARNING T o reduce the risk of fluid injection or splashing in the eyes or on the skin, do not hold a hand, body or rag in front of the spray tip when cleaning or checking a clogged tip.
8 308645 Installation/Operation How to Check the Gun Diffuser Operation Check the diffuser operation weekly . The gun diffuser/ seat (A) breaks up spray and reduces the risk of fluid injection when the tip is not installed. Perform the test below . If it fails, replace the entire Needle Kit, Part No.
308645 9 Installation/Operation How to Flush the Gun W ARNING T o reduce the risk of serious bodily injury , including splashing fluid in the eyes or on the skin, or static electric discharge when flushing: D Be sure the entire system, including flushing pails, are properly grounded.
10 308645 Service Fig. 8 23 1 T orque to 26 – 32 ft-lb (35 – 43 N.m) A B C D 1 4 05970 NOTE: The needle (C), diffuser/seat (A), gasket (B) and locknut (D) must be replaced together . They are included in Repair Kit 218070. Disassembly (See Fig. 8) 1.
308645 11 Service Replace Swivel (See Fig. 10) Disassembly 1. Follow Pressure Relief Procedure on page 5. 2. Push up on trigger guard (12) and swing trigger guard away from trigger (5). 3. Unscrew gun handle (6) from housing (26). Remove filter and clean in compatible solvent.
12 308645 Parts Drawing n 41 n 40 12 5 42 16 20 18 21 22 n 23 26 32 37 1 31 33 1 Included with 1 Model 238350, Series A Model 824004, Series A Model 239045, Series A 1 Purchase separately 2 2 6 43 15 .
308645 13 Parts List Model 238350, Series A; Model 824004, Series A Ref. No. Part N o. Description Qty . Ref. No. Part No. Description Qty . 1 218070 NEEDLE – DIFFUSER/SEA T KIT 1 5 238199 4-FINGER .
14 308645 Accessories FIL TERS 3000 psi (210 bar) Maximum Working Pressure. Adequate filtering is important for a good surface finish and to minimize tip clogging.
308645 15 T echnical Data Maximum Working Pressure 3600 psi (252 bar) . . . . . . Fluid Orifice Size 0.125 in. (3.18 mm) . . . . . . . . . . . . . . . Wetted Parts Stainless steel, Polyethylene, . . . . . . . . . Aluminum, Polyurethane, Nylon, R Brass, T ungsten carbide, UHMW Weight 17 oz.
16 308645 Graco W arranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco 824004 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco 824004 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco 824004 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco 824004 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco 824004, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco 824004.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco 824004. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco 824004 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.