Warnings 2 309935D Wa r n i n g s The f ollowing ar e general w ar nings related to the se tup , use, g rounding, mainten ance and repair of this equip ment. Additional, mo re sepcific warnings ma y be fo und through out the body of this manual wher e applicable .
WARNING 309935D 3 WA R N I N G EQUIPMENT MISUSE HAZARD Misuse can ca use death or serious injury . • Do not exceed the maximum workin g pressure or temperature rating of the lo west rated system component. Re ad T echnical Data in all equipment man uals.
Mise en garde 4 309935D Mise en gar de Les mises en gardes suivantes sont des mi ses en garde de sécurité relatives à la configuration, utilis ation, mise à la terre, maintenance e t réparation de ce matériel. D’aut res mises en garde pl us spécifiques figurent da ns ce manuel aux endroits co ncernés.
MISE EN GARDE 309935D 5 MISE EN GARDE D ANGER EN CAS DE MA UV AISE UTILISA TION DE L ’ÉQUIPEMENT T oute mauvaise utilisation du matériel peut pr ov oquer des b le ssures gra ves , voire mortelles. • Ne pas dépasser la pression ou tempér ature de ser vice maximum spécifiée de l’élément le plus f ai- ble du syst ème.
Advertencias 6 309935D Ad ver tencias A continuación se ofrecen adve rtencias en general relacionad as con la seguridad de la puesta en marcha , utilización, conexión a tierra, mant enimiento y reparación de este equ ipo. Además, puede e ncontrar advertencias adicionales a lo largo de este ma nual siempre que sea pert inente.
ADVERTENCIAS 309935D 7 AD VERTENCIAS PELIGROS DEBIDOS A LA UTILIZA CIÓN INCORRECT A DEL EQUIPO El uso incorrecto pued e causar la muer te o heridas gra v es. • No e xceda la presión máxima de t rabajo o la temper atura del co mponente con menor v alor nominal del sistema.
8 309935D English F rançais Español 1 Displa y Afficheur Visualización 2 ON/OFF switch Bouton MARCHE/ARRÊT Interruptor de encendido/apagado 3 Pressure control Commande de la pression Dispositivo d.
309935D 9 Grounding / Mise à la te rre / Cone xión a tierra English F rançais Español The spra yer m ust be grounded. Grounding reduces the risk of static and electric shock b y providing an escape wire for the electrical current due to static build up or in the ev ent of a shor t circuit.
10 309935D P ower Requirements Extension Cords • Do no t modify plug! If it wi ll not fit in outlet, ha v e grounded outlet installed b y a qualified elec tri- cian. Do no t use an adapte r . • 100 -120V units r equire 100-120 V A C, 50/60 Hz, 11A, 1 phase.
309935D 11 Pai l s • Solvent and oil/based fluids: follo w local code. Use only con- ductive met al pails, placed on a grounded surf ace such as concrete . • Do not place pail on a nonconduc- tive surf ace such as paper or card- board which interrupts ground ing continuity .
Pressure Relief Procedure / Décompression / Desco mpresión 12 309935D Pressure Relief Procedure / Dé compression / Descompresión Pressure Relief 1 T ur n power OFF . Wa i t 7 seconds for pow er to dissipate. 2 Lock gun trigger safety . Remov e guard and SwitchTip .
Setup / Installati on / Puesta en marcha 309935D 13 Setup / Installation / Puesta en mar c ha 1 Connect Graco airless h ose to spr ay er . Tighten securely . 2 Connect other end of hose to gun. 3 Tighten securely . 4 Remov e tip guard. 1 Brancher un fle xible Gr aco type airless sur le pulvér isat- eur .
Setup / In stallation / Puesta e n marcha 14 309935D 5 Check inlet strainer f o r clogs and debris. 6 Fill throat packing nut with TSL to prev ent premature packing wear . Do this each time you spra y . 7 T ur n power OFF . 8 Plug power supply cord into a properly grounded electrical outlet.
Setup / Installati on / Puesta en marcha 309935D 15 9 T ur n prime valv e down. 10 Place siphon tube set in grounded metal pai l par tially filled with flus hing fluid. Attach ground wire to pail and to true ear th ground. Do 1. - 5. of Star tup to flush out storage oil shipped in spra yer .
Startup / Dém arrage / Puesta en marcha 16 309935D Star tup / Démarrage / Puesta en mar cha 1 T ur n pressure control to lowest pr essure. 2 T ur n pow er ON . 3 Increase pressure 1/2 to star t motor and allow fluid to circulate through drain tube for 15 seconds; turn pressure down.
Startup / Démarrag e / Puesta en marcha 309935D 17 5 Hold gun against grounded metal flushing pail. T rigger gun and increase fluid pres- sure to 1/2. Flush 1 minute. Inspect for leaks . Do not stop leaks with hand or a rag! If leaks occur , do Pressure Relief .
Startup / Dém arrage / Puesta en marcha 18 309935D 1 Inser t SwitchTip. 2 Inser t metal seal and OneSeal. 3 Screw assemb ly onto gun. Tighten. 1 Monter la buse SwitchTip . 2 Mettre un joint métallique et un joint type OneSeal. 3 Visser l’ensemble sur le pistolet.
Startup / Démarrag e / Puesta en marcha 309935D 19 Sp r ay Clear Clog 1 Spray test patter n. Adjust pres- sure to e liminate heavy edges. Use smalle r tip size if pressure adjustment can not eliminate heavy edges. 2 Hold gun per pe ndicular, 10-12 in.
Digital Tracking System / Système de sui v i numéri que / Siste ma de rastreo digital 20 309935D Digital T racking System / Système de suiv i numérique / Sistema de rastreo digital Operation Main Menu Short press mov es to next displa y . Press and hold (5 seconds) chan ges units or resets data.
Digital Trac king System / Système de suivi numé rique / Sistem a de rastreo digit al 309935D 21 Operation Main Menu 4 Press and hold to re set to zero, or short press DTS button to mov e to Lif etime Gallons (o r Liters x 10).
Digital Tracking System / Système de sui v i numéri que / Siste ma de rastreo digital 22 309935D Secondary Menu 1D o Pressure Relief, steps 1 - 4 if they hav e not already been done. 2 Press DTS button and turn power s witch ON. 3 The model (e.g. U795 ) and MO T OR ON scroll past and then total motor run hours is display ed.
Digital Trac king System / Système de suivi numé rique / Sistem a de rastreo digit al 309935D 23 Secondary Menu Change Display Units: 5 Press and hold DTS button to clear error co de to zero . 6 Shor t press DTS button. The W-D O G scrolls past and OFF is display ed.
Cleanup / Ne ttoyag e / Limpieza 24 309935D Cleanup / Netto y age / Limpieza 1D o Pressure Relief, steps 1 - 4. Remov e siphon tube set from paint and place in flush- ing fluid. NO TE: Use water f or water base paint and mineral spirits for oil base pa int.
Cleanup / Nettoy age / Limpieza 309935D 25 5 T ur n prime valv e down and allow flushing fluid to circu- late fo r 15 seconds to clean drain tube. 6 Raise siphon tube abov e flushing fluid and run spray er for 15 to 30 seconds to drain fluid. 7 Close drain valve .
Cleanup / Ne ttoyag e / Limpieza 26 309935D 9 Remov e filters from gun and spra yer , if installed. Clean and inspect. Install filters. 10 If flushing with water , flush again with mineral spirits, or Pump Armor, to lea ve a protective coating to pre- vent freezing or corrosion.
Warranty 309935D 27 Wa r r a n t y Graco warrants all equipment referenced in this document which is manuf actured by Graco and bearing its name to be free from de fe c t s i n material and workmanship on the date of sale to the origin al purc haser for use.
Warranty 28 309935D T O PLA CE AN ORDER , contact your Gr aco distributor , or call 1-800- 690-2894 to identify the nearest distrib utor . All written and visual data conta ined in this d ocument reflects the latest prod uct information available at the time of publica tion.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco 309935d è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco 309935d - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco 309935d imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco 309935d ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco 309935d, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco 309935d.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco 309935d. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco 309935d insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.