Instructions–Parts List 309489E ENG Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. President 10:1 Ratio Air Spray System For transfer or supply of compatible fluids. With Evenflo r Automatic Pressure Control Model 954088, Series A 180 psi (12 bar , 1.
2 309489 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . . . . . . . . . .
3 309489 W ARNING SKIN INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
4 309489 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury . Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
5 309489 Installation General Information NOTE: Reference numbers and letters in parentheses refer to callouts in the Figs. and parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor . Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below .
6 309489 Installation NOTE: Reference numbers and letters in parentheses in the text refer to callouts in the figure illustrations and the parts drawing. The T ypical installation shown on page 7 is only a guide to electing and installing required and optional accessories.
7 309489 Installation T ypical Installation ti3003c KEY A B C D E H J K L M 38 52 1/2” Minimum A L C 38 E D J B H K 52 M Evenflo R Air Regulator Bleed-T ype Master A ir V alve Pump Runaway V alve Ai.
8 309489 Operation Pressure Relief Procedure With the Evenflo control, its bypass valve, and the pump Relax-A-V alve properly set, fluid pressure is relieved from the pump and hose each time you re- lease the gun trigger . Always engage the gun trigger safety when you stop spraying.
9 309489 Operation Use the air regulator (A) to control fluid pressure and pump speed. Always use the lowest pressure neces- sary to get the desired results. Higher pressures cause premature pump wear and spray tip wear , and usually do not improve the spray pattern.
10 309489 Maintenance Lubrication If your system includes an automatic air line lubricator , adjust the lubricator as instructed in the separate instruction manual. For manual lubrication, each day , remove the air inlet hose and place 12 to 15 drops of high quality , light motor oil in the inlet.
11 309489 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Relieve the pressure before you check or service any system equipment. NOTE: Check all possible problems and solutions before disassembling the pump.
12 309489 Service Displacement Pump Repair Before you start: 1. A packing repair kit, part no. 946761 is available. This kit includes two glands and eight packings for the motor as well as o-rings, packings, and wash- ers for the displacement pump. For the best re- sults use all the parts in the kit.
13 309489 Fig. 4 Fig. 5 06703 15 4 2 8 19 3/16” Piston Ball T ravel T orque to 100–150 ft-lb (136–204 N m) 1 43 30 31 32 34 35 33 50 2 3* 45 1 44 4 6 *8 7 *8 39 9 28 37 5 10* 12 14 15 16 17 .
14 309489 Parts 43 30 31 32 34 35 33 50 2 3* 45 1 44 4 6 *8 7 *8 39 9 28 37 5 10* 12 14 15 16 17 20 18* 19 22* 18* 20 21 *1 1 13 25 *23 26 27 24 52 53 46 48 47 51 42 29 36 49 38 17489a.
15 309489 Parts Model 954088, Series A Includes items 1–53 Ref. No. Part N o. Description Qty . 1 100016 W ASHER, lock 2 2 621201 STUD, clamp 1 3* 510636 PIN, spring, str 1 4 620850 ROD, connecting .
16 309489 T echnical Data Fluid pressure ratio 10:1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air pressure operating range 40–180 psi (3–12 bar) .
17 309489 Dimensions 1” (25.4 mm) 1–1/4” (31.8 mm) 14–1/2” (368.3 mm) 6–3/4” (171.4 mm) 3/8 npt 1 1/16” (17.5 mm) OD 45 45 6–1/2” (165.
18 309489 Dimensions 17488a 53–3/4” (1365.3 mm) 2–1/4” (47.2 mm) 39–1/4” (997 mm) 4” (101.6 mm) Model 954088, Series A Weight: 40 lb (18 Kg) 3/8 npsm Height of 55 gallon drum 34–3/4 (8.
19 309489 Notes.
20 309489 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco 309489E è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco 309489E - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco 309489E imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco 309489E ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco 309489E, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco 309489E.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco 309489E. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco 309489E insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.