Instructions/Parts List CycleFlo II 309004C ENG Pneumatic Pump Controller Controls pump speed for precise batching, mete ring, and dosing of fl uids at high or low pressures and flow rates. Not for use in explosive atmospheres. Part No. 195265 120 psi (0.
Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation .
Warning Symbol Cauti on Symbol This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
Fire, Explosion, and Electric Shock Hazard Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and resulting fire or explosion and serious injury. • Ground the equipment. • Proper grounding dissipates static electricity generated in the equipment.
General Description The CycleFlo II is a pneumatic pump controller that allows precise control over the cycle rate of the pump and therefor the flow rate. The pump cycle is initiated by a 120 volt signal. The pump cycle may be initiated by some other piece of e quipment such as a timer or a pH controller.
Fig.1 - Electrical Diagrams Pneumatic Connections 6 309004 Cycle Rate Adjustment Relay Solenoid Valves 120 Volt Signal.
The integrated air valves, have a common air inlet (1/4" NP T) po rt and two outlet ports A and B (1/4” Tube) toward the front of the unit. The exhaust is silenced with a muffler. Do not exceed 120 psi at the air in let to the unit. Refer to your pump owner’s manu al for the maximum air pressure limit of the pump.
Setup & Adjustment Cycles Per Minute (C PM) Rate The pump cycle rate is adj ustable to accommodate differ ent pump sizes, varying produ ct viscosities and product delivery speed. The pump cycle rate is measured in Cycle s Per Minute (CPM), i.e. the number of times the pump performs a pump cycle in one minute.
Operation Priming the Pump Prime the pump by applying a 120 Volt signal to the contro ller to allow the temporary operation of the pum p. This cycle rate may be increased or decrease d to facilitate pum p priming. Shut off electrical supply before making adjustments.
Parts Cycle rate adjustment relay Air Solenoid Valves Enclosure Part No. Description ----- Enclosure ----- Emblem (not shown – on front of unit) 115414 Cycle rate adjustment relay 115418 Air Solenoid Valves (Note: two valves are require d per controller) Optional Accessories Part No.
Typical Installation Diagram *Flow Sensors * Provided by others *Monitor / Controller Flow Controller sends an on/off signal (24VDC) to the isolation relay to control power to the CycleFlo II.
Typical Installation Diagram 9410A CycleFlo II Controller Compressed Air In Diaphragm Pump (Husky 205 shown) * PH Controller, Flow Controller Timer, etc. sends 110 VAC on/off signal to CycleFlo II Control ON/OFF signal (110VAC) * Flow Sensor * Provided by others Technical Data Power Requirements: 120Vac, 50/60 Hz, .
Mounting Hole Layout A ll m o u n ting tab s m ay be p l aced in e ith er p os itio n 7 3/ 8” ( 187 m m ) 5” (1 2 7 m m ) 7 3/ 8” (1 8 7 m m ) 5” ( 127 m m ) 13 309004.
Graco Standard Warranty Graco warrants all equipment refe renced in this document w hich is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Gr aco distributor to the original purchaser for use.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco 309004C è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco 309004C - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco 309004C imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco 309004C ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco 309004C, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco 309004C.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco 309004C. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco 309004C insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.